7. Additional charge calculation
7-1. Models:AOYG07LMCE and AOYG09LMCE
Refrigerant type
R410A
Refrigerant amount
g
700
¢
Refrigerant charge
Total pipe length
m
15 or less
20 (Max.)
20 g/m
Additional charge
g
0
100
7-2. Model:AOYG12LMCE
Refrigerant type
R410A
Refrigerant amount
g
850
¢
Refrigerant charge
Total pipe length
m
15 or less
20 (Max.)
20 g/m
Additional charge
g
0
100
7-3. Model:AOYG14LMCE
Refrigerant type
R410A
Refrigerant amount
g
1,050
¢
Refrigerant charge
Total pipe length
m
15 or less
20 (Max.)
20 g/m
Additional charge
g
0
100
- 45 -