10. Electrical characteristics
Model name
AOYG07LMCE AOYG09LMCE AOYG12LMCE AOYG14LMCE
Power
supply
Voltage
V
230 ~
Frequency
Hz
50
Max operating current *1
A
7.5
7.5
9.0
10.5
Starting current
A
3.3
3.5
4.8
6.3
Wiring
spec. *2
Circuit breaker current
A
15
Power cable
mm
2
1.5
Connection cable *3
mm
2
1.5
Limited wiring length
m
21
*1: Maximum current is the total current of the indoor unit and the outdoor unit.
*2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
As the regulations of wire size and circuit breaker differ in each country or region, select appropri-
ate devices complied to the regional standard.
*3: Limit voltage drop to less than 2%. If voltage drop is 2% or more, increase cable conductor
size.