Troubleshooting at the indoor unit display
(Troubleshooting at the display is available
either on the wired or wireless remote control.)
Troubleshooting at the wired remote control LCD
Self diagnosis
F ILT E R LAMP
T IME R LAMP
OP E R AT ION LAMP
MANUAL AUT O
If an error occurs, the following display will be shown.
("EE" will appear in the set room temperature display.)
Unit number
Error code
Ex. Self-diagnosis
Indoor signal error
Wired remote controller abnormal
Indoor room temperature sensor error
Indoor heat exchanger temperature
sensor (middle) error
Indoor heat exchanger temperature
sensor (inlet) error
F loat switch operated
Outdoor discharge pipe temperature
sensor error
Outdoor heat exchanger temperature
sensor (outlet) error
Outdoor temperature sensor error
C ompressor temperature sensor error
2-way valve temperature sensor error
3-way valve temperature sensor error
Outdoor heat exchanger temperature
sensor (middle) error
Indoor manual auto switch abnormal
P ower supply frequency detection error
IP M protection
C T error
C ompressor location error
Outdoor fan error
C onnected indoor unit abnormal
Outdoor unit computer communication
error
Indoor fan abnormal
Discharge temperature error
E xessive high pressure protection on
cooling
4-way valve abnormal
P ressure switch abnormal
C ompressor temperature error
Active filter abnormal
P F C circuit error
E rror contents
OPE R ATION
lamp (Green)
(2 times)
(2 times)
(2 times)
(2 times)
(3 times)
(3 times)
(3 times)
(3 times)
(3 times)
(3 times)
(3 times)
(4 times)
(4 times)
(5 times)
(5 times)
(5 times)
(5 times)
(5 times)
(5 times)
(6 times)
(7 times)
(7 times)
(7 times)
(7 times)
(7 times)
(8 times)
(8 times)
TIME R lamp
(Orange)
(8 times)
(2 times)
(3 times)
(4 times)
(6 times)
(2 times)
(3 times)
(4 times)
(8 times)
(2 times)
(4 times)
(2 times)
(3 times)
(5 times)
(6 times)
(7 times)
(8 times)
(2 or 3 times)
(2 times)
(3 times)
(4 times)
(5 times)
(6 times)
(2 or 3 times)
(4 times)
FIL TE R lamp
(R ed)
(2 times)
(3 times)
(4 times)
: 0.5s ON/0.5s OF F (F lash)
The OPERATION, TIMER and FILTER lamp operate as follows table
according to the error contents.
S U MO TU WE TH FR S A
E rror code
E rror contents
Indoor signal error
Wired remote controller abnormal
Indoor room temperature sensor error
Indoor heat exchanger temperature sensor (middle) error
Indoor heat exchanger temperature sensor (inlet) error
F loat switch operated
Outdoor discharge pipe temperature sensor error
Outdoor heat exchanger temperature sensor (outlet) error
Outdoor temperature sensor error
C ompressor temperature sensor error
2-way valve temperature sensor error
3-way valve temperature sensor error
Outdoor heat exchanger temperature sensor (middle) error
Indoor manual auto switch abnormal
P ower supply frequency detection error
IP M protection
C T error
C ompressor location error
Outdoor fan error
C onnected indoor unit abnormal
Outdoor unit computer communication error
Indoor fan abnormal
Discharge temperature error
E xessive high pressure protection on cooling
01
13
26
27
00
02
04
28
09
0C
06
0A
15
1d
1E
29
20
2A
17
18
1A
1b
1F
1c
12
0F
24
2c
16
2b
19
25
If "C O" appears in the unit number display, there is a remote controller
error. R efer to the installation instruction sheet included with the remote
controller.
: OF F
(R E D)
(OR ANG E )
(G R E E N)