01-12
14. FORCED COOLING OPERATION (TEST OPERATION)
Forced cooling operation is started when press MANUAL AUTO button for 10 seconds or more.
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation lamp and Timer lamp blink at the same time during the forced cooling operation.
They blink for 1 second ON and 1 second OFF on both Operation lamp and Timer lamp (same as test operation).
Forced cooling operation is released after 60 minutes of starting operation or pressing MANUAL AUTO button
for 3 seconds or pressing START/STOP button on the remote controller.
( Table15 : FORCED COOLING OPERATION )
When FORCED COOLING OPERATION is set, the operation is controlled as shown in Table15.
Forced cooling operation
Cooling
Hi
Horizontal
(It is changed follow as setting of remote controller)
OFF
Room Temp is not controlled
-
-
OPERATION MODE
FAN CONT. MODE
TIMER MODE
SETTING TEMP.
SETTING LOUVER
SWING
ECONOMY
15. COMPRESSOR PREHEATING
16.
ECONOMY OPERATION
The ECONOMY operation functions by pressing ECONOMY button on the remote controller.
At the maximum output, ECONOMY Operation is approximately 70% of normal air conditioner operation
for cooling and heating.
The ECONOMY operation is almost the same operation as below settings.
( Table 16 )
When the outdoor heat exchanger temperature is lower than 5°C and the all operation has
been stopped for 30 minutes, power is applied to the compressor and the compressor is heated.
(By heating the compressor, warm air is quickly discharged when operation is started.)
When operation was started, and when the outdoor temperature rises to 7°C (44.6°F) or greater,
preheating is ended.
17. POWERFUL OPERATION
The POWERFUL OPERATION functions by pressing POWERFUL button on the remote controller.
The indoor unit & outdoor unit will operate at maximum power as shown in Table17.
Release Condition is as follows.
[Cooling / Dry]
- Room temperature < Setting temperature - 1.5°C (-3°F) or Operation time has passed 20 minutes.
COMPRESSOR FREQUENCY Maximum
FAN CONT. MODE
Powerful
SETTING LOUVER
Cooling/ Dry : 3, Heating : 5
(Table17)
Powerful operation
=
=
[Heating]
- Room temperature > Setting tempe1.5°C (+3°F) or Operation time has passed 20 minutes.
Mode
Cooling/ Dry
Heating
Target temperature Setting temp.+1°C (2°F) Setting temp.-1°C (-2°F)
Содержание AOU09RL2
Страница 4: ......
Страница 5: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Страница 23: ...2 TROUBLE SHOOTING R410A WALL MOUNTED type INVERTER ...
Страница 53: ......
Страница 54: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Страница 61: ......
Страница 62: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan Mar 2012 Printed in Japan ...