background image

13

Air Cleaning Filter Installation

1. Open the Intake Grille and remove the Air

filters.

2. Install the Air cleaning filter set (set of 2).

1

Set the air cleaning filter into the air cleaning filter
frame.

2

Engage the latch at both ends of the filter with the
two hooks at the rear of the air cleaning filter frame.

Take care that the air cleaning filter does not project be-
yond the frame.

3

Engage the four fixing locations at the top and bot-
tom of the air cleaning filter frame with the hooks of
the air filter.

3. Install the two Air filters and close the

Intake Grille.

When air cleaning filters are used, the effect will increased
by setting the fan speed to “High”.

Replacing dirty Air cleaning filters

Replace filters with the following components (purchased
separately).

POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA13-1

Negative air ions deodorizing filter: UTR-FA13-2

1. Open the Intake Grille and remove the Air

filters.

2. Replace them by two new Air cleaning

filters.

1

Remove the old air cleaning filters in reverse order of
their installation.

2

Install in the same way as for installation of the air
cleaning filter set.

3. Install the two Air filters and close the

Intake Grille.

In regard to the Air Cleaning Filters

POLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)

The Air Cleaning Filters are disposable filters. (They can
not be washed and reused.)

For storage of the Air Cleaning Filters, use the filters as
soon as possible after the package has been opened.
(The air cleaning effect decreases when the filters are left
in the opened package)

Generally, the filters should be exchanged about every
three months.

Please buy delicated air cleaning filters (UTR-FA13-1) (Sold
separately) to exchange the used dirty air cleaning filters.

[Negative air ions deodorizing filter (one sheet) — light blue]

The filters should be exchanged about every three years
so as to maintain the deodorizing effect.

Filter frame is not a one-off product.

Please buy delicated deodorizing filter (UTR-FA13-2) (Sold
separately) when exchanging the filters.

Maintenance of Deodorizing Filters

In order to maintain the deodorizing effect, please clean the
filter in the follow way once three months.

1

Remove the deodorizing filter.

2

Clean with water and dry in the air.
1) Flush the filters with high-pressure hot water until

the surface of the filters are covered with water.
Please flush with diluent neutral detergent.
Never wash by reaming or rubbing, otherwise it
will damage the deodorizing effect.

2) Rinse with water flow.
3) Dry in shade.

3

Reinstall the deodorizing filter.

Air cleaning filter set

Air cleaning filter frame

Air cleaning filter

Hook (2 places at the rear)

Latch (2 places)

Rear of the filter

Fixing location, hook (6 places)

CLEANING AND CARE

Air Filter

(Right & Left)

Air Filter

(Right & Left)

Air Filter(Right & Left)

Air Filter

(Right & Left)

9315345226_En_body

2009.8.19, 10:11

13

Содержание AOTR30JFT

Страница 1: ...ITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product 9315345226_En_cover 2009 8 19 10 23 1 ...

Страница 2: ...e objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage...

Страница 3: ...PANEL The indoor unit s Open Panel can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIET OPERATION When the FAN button is used to select QUIET the unit be gins super quiet operation the indoor unit s airflow is re duced to produce quieter operation POLYPHENOL CATECHIN A...

Страница 4: ...itate explanation the accompanying illustra tion has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current op eration Fig 6 9315345226_En_body 2009 8 19 10 11 3 ...

Страница 5: ...Speed Display Temperature SET Display a SLEEP Display b SWING Display NAME OF PARTS Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling op...

Страница 6: ... arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 W Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 O to adjust the clock to the current time button Press to advance the time button Press to reve...

Страница 7: ...ature To Set the Fan Speed Press the FAN button Fig 6 P Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes slower Fan The fan runs at the low fan speed The fan will operate at a ...

Страница 8: ...st the temperature to the value set in the thermostat The monitor operation range is 2 C relative to the thermostat set ting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room You cannot heat the room during Dry mode During Dry m...

Страница 9: ...re display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by t...

Страница 10: ...he SLEEP timer function automatically modifies the thermostat setting in accord ance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automatically raised 1 C every sixty minutes When the thermostat has been raised a total of 2 C the thermostat setting at that time is main...

Страница 11: ...omatically returned to the 3 range When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 R Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 Du...

Страница 12: ... airflow direc tion Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizontal position the lower airflow direction louver moves swings to direct airflow to a wide area Left right swing The airflow direction louvers move swing in the left right airflow direction Up down left right swing The airflow direction louvers move swing in both the up down and left ri...

Страница 13: ...es of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wa...

Страница 14: ...hey can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning...

Страница 15: ...or unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting The fan may operate at very low speed during Dry operation or when ...

Страница 16: ... the problem persists after performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 5 and the TIMER Indicator Lamp Fig 3 6 flashes or only the TIMER Indicator Lamp Fig 3 6 flashes immediately stop operation disconnect the Power Supply and consult authorized service personnel AUTO Restart In Event of Power Interruption The air conditioner power has been in...

Страница 17: ...an those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath Abou...

Страница 18: ...9315345226_En_body 2009 8 19 10 11 17 ...

Страница 19: ...9315345226_En_body 2009 8 19 10 11 18 ...

Страница 20: ...9315345226_En_body 2009 8 19 10 11 19 ...

Отзывы: