4) Auto restart
Enable or disable automatic restart after a power interruption.
(
... Factory setting)
Setting description
Function number
Setting value
Enable
40
00
Disable
01
* Auto restart is an emergency function such as for power outage etc.
Do not attempt to use this function in normal operation.
Be sure to operate the unit by remote controller or external device.
5) Room temperature sensor switching
(Only for wired remote controller)
When using the Wired remote controller temperature sensor, change the setting to "Both" (01).
(
... Factory setting)
Setting description
Function number
Setting value
Indoor unit
42
00
Both
01
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
6) Remote controller signal code
(Only for wireless remote controller)
The indoor unit signal code can be changed.
Select the appropriate signal code.
(
... Factory setting)
Setting description
Function number
Setting value
A
44
00
B
01
C
02
D
03
7) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
... Factory setting)
Setting description
Function number
Setting value
Operation/Stop mode
46
00
(Setting change prohibited)
01
Forced stop mode
02
8) Indoor unit fan control for energy saving for cooling
Enable or disables the power-saving function by controlling the indoor unit fan rotation when
the outdoor unit is stopped during cooling operation.
(
... Factory setting)
Setting description
Function number
Setting value
Disable
49
00
Enable
01
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following
the setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very
low speed.
Содержание AOTG09KMCA
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE ASTG09KMCA ASTG12KMCA DTR_AS081E_01 2013 07 19 ...
Страница 10: ... 01 07 WALL MOUNTED TYPE ASTG09 12KMCA WALL MOUNTED TYPE ASTG09 12KMCA INSTALLATION PLACE Unit mm ...
Страница 19: ... 01 16 WALL MOUNTED TYPE ASTG09 12KMCA WALL MOUNTED TYPE ASTG09 12KMCA SOUND LEVEL CHECK POINT 8 2 ...
Страница 30: ...2 OUTDOOR UNIT SINGLE TYPE AOTG09KMCA AOTG12KMCA DTR_AO143E_01 2013 07 19 ...
Страница 35: ... 02 04 OUTDOOR UNIT AOTG09 12KMCA OUTDOOR UNIT AOTG09 12KMCA WIRING DIAGRAMS 4 MODELS AOTG09KMCA AOTG12KMCA ...
Страница 41: ... 02 10 OUTDOOR UNIT AOTG09 12KMCA OUTDOOR UNIT AOTG09 12KMCA SOUND LEVEL CHECK POINT 8 2 ...