background image

8

To Use the ON timer or OFF timer

1

Press the START/STOP button.
(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION indicator lamp (red) will light.

2

Press the TIMER button to select the OFF timer or ON
timer operation.

Each time the button is pressed the timer function changes in the follow-
ing order:

RESET

OFF

ON

PROGRAM(OFF

 ON, OFF 

 ON)

The indoor unit’s TIMER indicator lamp (green) will light.

3

Use the SET TIME buttons to adjust the desired OFF
time or ON time.

Set the time while the time display is flashing (the flashing will continue
for about five seconds).

 button:

Press to advance the time.

 button:

Press to reverse the time.

About five seconds later, the entire display will reappear.

To Use the PROGRAM timer

1

Press the START/STOP button.
(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION indicator lamp (red) will light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired
mode and times.
About three seconds later, the entire display will reappear.
The indoor unit’s TIMER indicator lamp (green) will light.

3

Press the TIMER button to select the PROGRAM timer
operation (either OFF 

 ON or OFF 

 ON will display).

The display will alternately show “OFF timer” and “ON timer”, then change
to show the time setting for the operation to occur first.

The PROGRAM timer will begin operation. (If the ON timer has been
selected to operate first, the unit will stop operating at this point.)

About five seconds later, the entire display will reappear.

TIMER OPERATION

s

s

s

t

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5).

To Cancel the Timer

Use the TIMER button to select “TIMER
RESET”.
The air conditioner will return to normal
operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change the operating
conditions (Mode, Fan Speed, Thermostat
Setting), after making the timer setting,
wait until the entire display reappears, then
press the appropriate buttons to change
the operating condition desired.

To Cancel the Timer

Use the TIMER button to select “TIMER
RESET”.
The air conditioner will return to normal
operation.

To Change the Timer Settings

1. Follow the instructions given in the section

“To Use the ON Timer or OFF Timer” to se-
lect the timer setting you wish to change.

2. Press the TIMER button to select either

OFF

 ON or OFF 

 ON.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting),
after making the timer setting, wait until
the entire display reappears, then press the
appropriate buttons to change the operat-
ing condition desired.

About the PROGRAM timer

The PROGRAM timer allows you to integrate OFF timer
and ON timer operations in a single sequence. The se-
quence can involve one transition from OFF timer to ON
timer, or from ON timer to OFF timer, within a twenty-
four hour period.

The first timer function to operate will be the one set near-
est to the current time. The order of operation is indi-
cated by the arrow in the remote control unit’s display
(OFF

 ON, or OFF 

 ON).

One example of PROGRAM timer use might be to have
the air conditioner automatically stop (OFF timer) after
you go to sleep, then start (ON timer) automatically in
the morning before you rise.

About the ON timer

The timer function is designed to bring your room to a
comfortable temperature by the set time; as a result, the
unit automatically begins operation before the set time
so that the room reaches the desired temperature by the
time set on the timer (“Nice-Morning Timer”).

The hotter it is in summer, or the colder it is in winter, the
earlier that operation will begin.

* During Heating Operation ....... from 45 to 10 minutes be-

fore set time.

During Cooling/Dry Operation ... from 20 to 10 minutes be-

fore set time.

During Fan Operation .............. at the set time.

Содержание AOT18A

Страница 1: ...OUNTED TYPE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED OPERATING MANUAL Indoor Unit AST18AB AST18RB AST24AB AST24RB AST30AB AST30RB Outdoor Unit AOT18A AOT18R AOT24A AOT24R AOT30A AOT30R P N9369993015 ...

Страница 2: ...tand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure t...

Страница 3: ...uring the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction sw...

Страница 4: ...3 9 B C 7 6 5 4 8 2 D SWING SWING TIMER OPERATION G E F Fig 2 Fig 3 Fig 4 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 6 Fig 1 Fig 8 Fig 7 Fig 5 G E F ...

Страница 5: ... flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner V Remote Control Unit Display Fig 8 W Transmit Indicator X Clock Display Y Operating Mode Display Z Timer Mode Display Fan Speed Display Temperature Set Display Timer Set Indicator Temperature Set Indicator Fig 1 Indoor Unit 1 Operating Contro...

Страница 6: ...de to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the ...

Страница 7: ... the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as ...

Страница 8: ... very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan set ting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to ...

Страница 9: ... STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change th...

Страница 10: ...ooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time Set tim...

Страница 11: ...g 10 ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle Vertical up down direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION VERTICAL SET button Horizontal right left direction of airflow is adjusted by pressing the remote control unit s AIR FLOW DIRECTION HORIZONTAL SET button DANGE...

Страница 12: ...he air UP DOWN direction flaps in the range 4 to 6 for long periods of time since water vapor may condense near the outlet port and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING will light In this mode the RIGHT LEFT air direction louvers will swing automat...

Страница 13: ...he intake grille fully to remove 2 Clean with water Remove dust with a vacuum cleaner wipe the unit with warm water then dry with a clean soft cloth 3 Replace the intake grille 1 Holding the intake grille horizontally fasten the two upper hooks on the unit 2 Press the intake grille down at the lower sides to close Intake Grille Air filter handle Hooks two places Intake Grille Hooks two places Befo...

Страница 14: ...result of minute expansion and contraction of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry oper...

Страница 15: ... conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your...

Страница 16: ...umidifying and air circulation of rooms in ordinary dwellings Should the power supply to the air conditioner be inter rupted by a power failure the air conditioner will restart automatically in the previously selected mode once the power is restored Should a power failure occur during TIMER operation the timer will be reset and the unit will begin or stop operating under the new timer setting In t...