Limit of maximum speed based on outdoor temperature
36°C
A zone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
E zone
F zone
10°C
0°C
12°C
2°C
Outdoor
temperature drops
Outdoor
temperature rises
Unit: rps
Model name
Outdoor
temperature zone
Indoor unit fan mode
HIGH
MED
LOW
QUIET
ASHG07KGTE
A zone
62
36
24
18
B zone
62
36
24
18
C zone
62
36
24
18
D zone
44
34
22
16
E zone
44
34
22
16
F zone
44
34
22
16
ASHG09KGTE
A zone
67
38
26
18
B zone
67
38
26
18
C zone
67
38
26
18
D zone
47
36
24
16
E zone
47
36
24
16
F zone
47
36
24
16
ASHG12KGTE
ASHG14KGTE
A zone
83
42
30
18
B zone
83
42
30
18
C zone
83
42
30
18
D zone
58
40
28
16
E zone
58
40
28
16
F zone
58
40
28
16
1-1. Cooling operation
- (04-2) -
1. Rotation number control of compressor
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание AOHG07KGCA
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2022 3 11 SR_CH01_AS069EG_01 ...
Страница 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 3 11 SR_CH02_AS069EG_01 ...
Страница 33: ...3 TROUBLESHOOTING 2022 03 25 SR_CH03_AS069EG_01 ...
Страница 36: ......
Страница 89: ...4 CONTROL AND FUNCTIONS 2022 03 25 SR_CH04_AS069EG_01 ...
Страница 91: ...8 6 High temperature and high pressure release control heating mode 04 32 CONTENTS continued ...
Страница 92: ......
Страница 125: ...5 FILED WORKING 2022 03 25 SR_CH05_AS069EG_01 ...