SETTING METHOD
14-2.
Stop the operation of air conditioner before this setting.
LOW NOISE MODE
14-2-1.
SW1
SW2
SW3
SW4
SW5
LED lamp part
(1) Switch to “Local setting mode” by pressing [MODE] button (SW1) for 3 seconds or more.
(2) Confirm that the (POWER / MODE) blinks 9 times, then press [ENTER] button (SW3).
POWER
MODE
ERROR
(L1) (L2) (L3) (L4) (L5) (L6)
PUMP
DOWN
LOW NOISE
PEAK CUT
Blinks
(9 times)
Sign “ ” : Lights off
(3) Press [SELECT] button (SW2), and adjust LED lamp as shown below. (Current setting is
displayed)
(L2) (L3)
LOW NOISE
Blink
LOW NOISE
MODE
(4) Press [ENTER] button (SW3).
(L2) (L3)
LOW NOISE
LOW NOISE
MODE
Sign “ ” : Lights on
(5) Press [SELECT] button (SW2), and adjust LED lamp as shown in below figure.
PEAK CUT
MODE 1: Rated noise value -2dB
MODE 2: Rated noise value -4dB
Blink
Blink
(L4) (L5) (L6)
The noise of MODE2 is lower than that of MODE1.
(6) Press [ENTER] button (SW3) to fix it.
PEAK CUT
MODE 1: Rated noise value -2dB
MODE 2: Rated noise value -4dB
(L4) (L5) (L6)
(7) Return to “Operating status display (Normal operation)” by pressing [EXIT] button (SW4).
• To restart the setting during the process, return to "Operating status display (Normal operation)" by pressing the [EXIT]
button once.
Содержание AO*G45LETL series
Страница 2: ...1 INDOOR UNIT DTR_AR066E_02 2013 11 08 DUCT TYPE AR G45LHTA AR G54LHTA ...
Страница 11: ... 01 08 DUCT TYPE AR G45 54LHTA DUCT TYPE AR G45 54LHTA WIRING DIAGRAMS 555 MODEL AR G45LHTA AR G54LHTA ...
Страница 34: ...DTR_AO136E_02 2013 11 08 SINGLE TYPE AO G45LETL AO G54LETL 2 OUTDOOR UNIT ...
Страница 43: ... 02 08 OUTDOOR UNIT AO G45 54LETL OUTDOOR UNIT AO G45 54LETL WIRING DIAGRAMS 666 MODELS AO G45LETL AO G54LETL ...