Before servicing the unit, turnings of all power supplies.
Then, do not touch the electric parts for 10 minutes due to the risk of electric shock.
4. Inverter PCB removal
Start from removing Front panel and Valve and swtich cover.
3. Open electric box cover and
disconnect 6 connectors.
(P1 / P5 / P20 / P30 / P60 / P650 )
1. Remove the screws ( 2 places ).
2. Remove the Hex socket screw.
Open Compressor terminal cover
and disconnect 3 wires.
4. Release cables from cable gide and
remove the screw and remove electric box.
5. Disconnect 5 connectors.
6. Cut binder and remove earth wire.
7. Remove the screws ( 7 places ).
8. Remove the Inverter PCB from case.
9. Remove the EMI filters. ( 3 places )
Remove the Core. ( 1 place )
Before mounting a new PCB, wipe all old thermal
grease of the heat sink then apply new one.
Tips!