- (01 - 37) -
C
A
SS
ET
TE T
YP
E
AU
A
45
-5
4LC
C
A
SS
ET
TE T
YP
E
AU
A
45
-5
4LC
1-4. Setting the vertical wind direction adjustment range
•The use of “upward” is recommended if you wish to prevent draft.
(The unit is factory-set to “00”)
•Note that the ceiling may become dirty depending on your usage condition.When this happens,
we recommend the use of the optional “PANEL SPACER KIT”.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
23
00
upward
01
•We recommend the use of “upward” when using “High ceiling mode”.
upward
1-5. Setting the Cooler Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be selected as shown in the table below.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
30
00
Lower control
01
1-6. Setting the Heater Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be changed as shown in the table below.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Standard
31
00
Lower control
01
Slightly warmer control
02
Warmer control
03
1-7. Auto Restart
The following settings are also possible, depending on the operating conditions.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
Yes
40
00
No
01
1-8. Indoor Room Temperature Sensor Switching Function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote controller temperature
sensor.
(
. . .Factory setting)
Setting Description
Function Number
Setting Value
No
42
00
Yes
01
If setting value is “00”,
•
room temperature is controlled by the indoor unit temperature sensor.
If setting value is “01”,
•
room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor.
Содержание AO*A45LBTL
Страница 2: ...1 INDOOR UNIT D2D_AU041E 04 2011 03 01 CASSETTE TYPE AU A45LCLU AU A54LCLU ...
Страница 13: ... 01 10 CASSETTE TYPE AU A45 54LC CASSETTE TYPE AU A45 54LC WIRING DIAGRAMS 555 MODEL AU A45LC AU A54LC ...
Страница 44: ...D2D_AO052E 01 2009 04 30 SINGLE TYPE AO A45LBTL 2 OUTDOOR UNIT ...
Страница 48: ... 02 03 OUTDOOR UNIT AO A45L OUTDOOR UNIT AO A45L REFRIGERANT CIRCUIT 22222 MODEL AO A45L ...
Страница 49: ... 02 04 OUTDOOR UNIT AO A45L OUTDOOR UNIT AO A45L WIRING DIAGRAMS 22222 MODEL AO A45L ...
Страница 57: ...DTR_AO081E_01 2011 03 01 SINGLE TYPE AO A45LCTL AO A54LCTL 2 OUTDOOR UNIT ...
Страница 63: ... 02 05 OUTDOOR UNIT AO A45 54LC OUTDOOR UNIT AO A45 54LC REFRIGERANT CIRCUIT 444 MODEL AO A45LC AO A54LC ...
Страница 64: ... 02 06 OUTDOOR UNIT AO A45 54LC OUTDOOR UNIT AO A45 54LC WIRING DIAGRAMS 555 MODEL AO A45LC AO A54LC ...