![Fujitsu AO*A45LBTL Скачать руководство пользователя страница 74](http://html.mh-extra.com/html/fujitsu/ao-a45lbtl/ao-a45lbtl_design-and-technical-manual_118245074.webp)
- (02 - 16) -
O
U
TD
O
O
R U
N
IT
AO
A
45
-5
4LC
O
U
TD
O
O
R U
N
IT
AO
A
45
-5
4LC
PEAK CUT MODE
Operation that suppressed the current value can be performed by means of the following on-
•
site work.
The air conditioner is set to the Peak cut mode when closing the contact input of a
commercial ON/OFF switch to a connector on the outdoor control PC board.
Circuit diagram example
z
Contact capacity : 24VDC or more, 10mA or more.
Outdoor unit
control PC board
Connector
1
2
Signal
Field supply
*10m
Connected unit
Ex.) Switch
* Make the distance from the PC board to the connected unit within 10m.
Use the following parts and construct a circuit as shown above.
•
Input Signal∙∙∙ON : Peak cut mode, Input Signal∙∙∙OFF : Normal operation
•
*Set the "Peak cut mode" level, refer to "13.FUNCTION SETTING".
ON
OFF
ON
OFF
Input Signal
Peak cut mode
Parts (Optional)
z
Parts name
External connect kit
Model name
UTY-XWZXZ3
Содержание AO*A45LBTL
Страница 2: ...1 INDOOR UNIT D2D_AU041E 04 2011 03 01 CASSETTE TYPE AU A45LCLU AU A54LCLU ...
Страница 13: ... 01 10 CASSETTE TYPE AU A45 54LC CASSETTE TYPE AU A45 54LC WIRING DIAGRAMS 555 MODEL AU A45LC AU A54LC ...
Страница 44: ...D2D_AO052E 01 2009 04 30 SINGLE TYPE AO A45LBTL 2 OUTDOOR UNIT ...
Страница 48: ... 02 03 OUTDOOR UNIT AO A45L OUTDOOR UNIT AO A45L REFRIGERANT CIRCUIT 22222 MODEL AO A45L ...
Страница 49: ... 02 04 OUTDOOR UNIT AO A45L OUTDOOR UNIT AO A45L WIRING DIAGRAMS 22222 MODEL AO A45L ...
Страница 57: ...DTR_AO081E_01 2011 03 01 SINGLE TYPE AO A45LCTL AO A54LCTL 2 OUTDOOR UNIT ...
Страница 63: ... 02 05 OUTDOOR UNIT AO A45 54LC OUTDOOR UNIT AO A45 54LC REFRIGERANT CIRCUIT 444 MODEL AO A45LC AO A54LC ...
Страница 64: ... 02 06 OUTDOOR UNIT AO A45 54LC OUTDOOR UNIT AO A45 54LC WIRING DIAGRAMS 555 MODEL AO A45LC AO A54LC ...