SAFETY PRECAUTIONS

 

Before using the appliance, read these “PRECAUTIONS” thoroughly 

and operate in the correct way.

 

The instructions in this section all relate to safety; be sure to maintain 

safe operating conditions.

 

“WARNING” and “CAUTION” have the following meanings in these 

instructions:

 WARNING

This mark indicates procedures which, if im

-

properly performed, might lead to the death or 

serious injury of the user.

 CAUTION

This mark indicates procedures which, if im

-

properly performed, might possibly result in per-

sonal harm to the user, or damage to property.

PRECAUTIONS ON USE

 WARNING

 

● Do not keep exposing oneself to the direct wind of air conditioner for a 

long time.

 

● Do not insert fingers or objects into the outlet port or intake grille.

 

● Except for EMERGENCY, never turn off main as well as sub breaker 

of the indoor units during operation. It will cause compressor failure as 

well as water leakage. First, stop the indoor unit by operating the con

-

trol unit, converter or external input device and then cut the breaker. 

Make sure to operate through the control unit, converter or external 

input device.

 

If the power supply cord of this appliance is damaged, it should only 

be replaced by the authorized service personal, since special purpose 

tools and specified cord are required.

 

● If any refrigerant happens to leak, extinguish any flames, ventilate the 

room and get in touch with authorized service personnel.

 CAUTION

 

● Do not place animals or plants in the direct path of the airflow.

 

● Do not direct airflow at fireplaces or heating apparatus.

 

● Do not block or cover the inlet port and outlet port.

 

● Do not climb on, or place objects on, the air conditioner.

 

● Do not set flower vases or water containers on top of air conditioners.

 

● Do not hang objects from the indoor unit.

 

Do not place any other electronic appliance or furniture. Otherwise, 

water drop from the product may cause damage or failure of the appli-

ance or furniture.

 

● Always turn off the electrical breaker whenever cleaning the air condi

-

tioner or the air filter.

 

Do not pour water or cleaning solvent on the unit directly, or wash the 

unit with them.

 

● Do not expose the air conditioner directly to water.

 

Do not operate the air conditioner with wet hands.

 

● Check the condition of the installation stand for damage.

 

● Operate only with air filters installed.

 

● Do not drink the water drained from the air conditioner.

 

● Do not apply any heavy pressure to radiator fins.

 

● Do not use inflammable gases near the air conditioner.

 

Do not touch the piping during operation.

 

Ensure that any electronic equipment is at least 1 m away from either 

the indoor or outdoor units.

 

This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of ex

-

perience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for 

their safety. Children should be supervised to ensure that they do not 

play with the appliance.

 

If the unit is not used for more than a month, perform a ventilation 

operation before preforming a regular operation in order to dry the 

internal components.

Note:

Switching the operating mode in the heat recovery system may require 

some time to prepare for operation. Please note that this is not a fault.

PRECAUTIONS ON INSTALLATION

 CAUTION

 

Do not attempt to install this air conditioner by yourself.

 

This unit contains no user-serviceable parts. Always consult authorized 

service personnel for repairs.

 

When moving, consult authorized service personnel for disconnection 

and installation of the unit.

 

The unit must be grounded.

 

● Make sure drain work is implemented properly for drainage.

 

● Avoid installing the air conditioner near a fireplace or other heating 

apparatus.

 

● When installing the indoor and outdoor units, take precautions to pre

-

vent access by infants.

NAME OF PARTS

(1)

(2)-1

(2)-2

(2)-3

(1) 

Air filter (in air intake grille)

(2) 

Airflow direction flaps

 

The name of the outlet ports (in “Individual Horizontal Hold setting” by 

the wired remote controller). Please refer to the “AIRFLOW DIREC-

TION”. 

(2)-1: Outlet 1 (Center fan) 

(2)-2: Outlet 2 (Side fan) 

(2)-3: Outlet 3 (Side fan)

(3) IR Receiver (optional)

(4)

(3)

(5)
(6)
(7)
(8)

(4) OPERATION Indicator Lamp (Green): It lights on 

while operating.

(5) TIMER Indicator Lamp (Orange): It lights on while 

timer is working.

(6) FILTER Indicator Lamp (Red): Lights on when it 

is time to clean the filter. Clean the filter according 

to “CLEANING AND CARE”. Once the cleaning is 

completed, turn off the indicator lamp by operating 

the Filter sign reset function on the remote control-

ler.

(7) Manual auto button: It is used to operate it while 

remote controller is not available.

(8) Remote control signal receiver: It is the place to 

receive the signals from the remote controller.

CONTENTS

SAFETY PRECAUTIONS

 ........................................................................ 1

NAME OF PARTS ................................................................................... 1

MANUAL AUTO OPERATION ................................................................ 2

COMFORT AIRFLOW ............................................................................. 2

AIRFLOW DIRECTION ........................................................................... 2

OPERATING TIPS .................................................................................. 3

CLEANING AND CARE........................................................................... 4

TROUBLESHOOTING ............................................................................ 5

SPECIFICATIONS ................................................................................... 6

OPERATING MANUAL

PART No. 9383490019

VRF system indoor unit (3D flow cassette type)

9383490019_OM.indb   1

05/02/2019   18:24:37

Содержание AIRSTAGE AUXS018GLEH

Страница 1: ...ος κασέτας με ροή 3D Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR tipo de cassete de fluxo 3D Guarde este manual para consulta futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ кассетный тип с 3D потоком Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE 3D akış kaset tipi Bu kılavuzu ileride başvurmak üzere s...

Страница 2: ...e inflammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of ex perience and knowledge unless they have been given supervision or instruction co...

Страница 3: ...erature 23 C Stopping Operation Press the MANUAL AUTO button on the IR Receiver COMFORT AIRFLOW Airflow direction vertical horizontal is set to provide air conditioning for the entire room It is recommended to use this setting While the Comfort airflow has been set the airflow direction is fixed and cannot be set manually To use this setting the specific wired remote controller is required For det...

Страница 4: ...eating Mode Outdoor temperature Please refer to the specification of outdoor units Indoor temperature 18 to 32 C DB 10 to 30 C DB Indoor humidity About 80 or less If the air conditioner is operated under higher temperature conditions than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under condition...

Страница 5: ...r The diagram shows the rear view seen from the diagonally behind 1 Remove three hooks to release and hang the in take grille Hooks Back Front Loosen the screws and remove two hanging wires Tap tight screw 2 Hold the handle to lift the air filter The diagram shows the removed intake grille for explanatory purpose Handles Air Filter Release the hooks Air Filter Side view Back Front 3 Remove three h...

Страница 6: ...ps When IR Receiver is installed The OPERATION indicator lamp green flashes An oil recovery operation is being performed See page 3 The OPERATION indicator lamp green flashes An automatic defrosting operation is being per formed See page 3 The OPERATION indicator lamp green and TIMER indicator lamp orange are flashing alternately It has recovered from a power outage The OPERATION indicator lamp gr...

Страница 7: ...erature and use it Tem perature may not fall down depending on the room conditions While high humidity or the room temperature is high See page 3 In the following situations stop operation immediately and get in touch with authorized service personnel The problem cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is flashing very fast When IR Re...

Страница 8: ...9383490019_OM_AR indd 7 9383490019_OM_AR indd 7 05 02 2019 18 30 47 05 02 2019 18 30 47 ...

Отзывы: