background image

En-3

Low ambient cooling

 

When the outdoor temperature drops, the outdoor unit’s fans may 

switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

Heating mode operates on the heat-pump principle, absorbing heat 

from outdoor air and transferring that heat indoors. As a result, the 

operating performance is reduced as outdoor air temperature drops. 

If you feel that insufficient heating performance is being produced, we 

recommend you use this air conditioner in conjunction with another 

type of heating appliance.

 

Heating mode heat your entire room by recirculating air throughout the 

room, with the result that some time may be required after first starting 

the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

When using the Heating mode under conditions of low outdoor air 

temperature high humidity, frost may form on the outdoor unit, result-

ing in reduced operating performance. In order to prevent this kind of 

reduced performance, this unit is equipped with a Microcomputer-con-

trolled automatic defrosting function. If frost forms, the air conditioner 

will temporarily stop, and the defrosting circuit will operate briefly (for 

about 4 to 15 minutes).  

During Automatic Defrosting operation, the OPERATION indicator 

lamp (green) will flash (When IR Receiver is installed).

 

Oil recovery operation

 

Periodically, the oil recovery operation is performed in order to return 

compressor oil to the outdoor unit. During oil recovery operation, the 

OPERATION indicator lamp (green) will flash for about 10 minutes 

(When IR Receiver is installed).

Temperature and humidity range

 

The temperature and humidity required for operating this product is as 

shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor  

temperature

Please refer to the specification of outdoor units.

Indoor  

temperature

18 to 32 °C DB

10 to 30 °C DB

Indoor humidity

About 80% or less

 

If the air conditioner is operated under higher temperature conditions 

than those listed, the built-in protection circuit may operate to prevent 

internal circuit damage. Also, during Cooling and Dry modes, if the unit 

is used under conditions of lower temperature than those listed above, 

the heat-exchanger may freeze, leading to water leakage and other 

damage.

 

If the unit is used for long periods under high-humidity conditions, 

condensation may form on the surface of the indoor unit, and drip onto 

the floor or other objects underneath.

 

Do not use this unit for any purposes other than the Cooling, Heating, 

Dehumidifying, and air-circulation of rooms in ordinary dwellings.

Vertical airflow direction

The vertical airflow direction can be controlled with the remote controller.

Swing

The swinging vertical airflow direction can be set.

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

Multiple indoor units can be connected within the same system. De-

pending on the system, choice of operating mode are limited.

Cooling priority state:

When the other indoor units within the same system operate in cooling 

or dry mode, heating cannot be selected at the same time.

Heating priority state:

When the other indoor units within the same system operate in heating 

mode, cooling and dry mode cannot be selected at the same time.

Standby state:

The standby state activates when 2 or more indoor units start up at the 

same time in different mode. Any indoor unit other than priority mode 

will wait in standby state until priority mode changes (operation starts 

as soon as priority is switched).

At this time, the OPERATION indicator lamp (green) lights up and the 

TIMER indicator lamp (orange) flashes (When IR Receiver is installed).

9383490019_OM.indb   3

05/02/2019   18:24:39

Содержание AIRSTAGE AUXS018GLEH

Страница 1: ...ος κασέτας με ροή 3D Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR tipo de cassete de fluxo 3D Guarde este manual para consulta futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ кассетный тип с 3D потоком Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE 3D akış kaset tipi Bu kılavuzu ileride başvurmak üzere s...

Страница 2: ...e inflammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of ex perience and knowledge unless they have been given supervision or instruction co...

Страница 3: ...erature 23 C Stopping Operation Press the MANUAL AUTO button on the IR Receiver COMFORT AIRFLOW Airflow direction vertical horizontal is set to provide air conditioning for the entire room It is recommended to use this setting While the Comfort airflow has been set the airflow direction is fixed and cannot be set manually To use this setting the specific wired remote controller is required For det...

Страница 4: ...eating Mode Outdoor temperature Please refer to the specification of outdoor units Indoor temperature 18 to 32 C DB 10 to 30 C DB Indoor humidity About 80 or less If the air conditioner is operated under higher temperature conditions than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under condition...

Страница 5: ...r The diagram shows the rear view seen from the diagonally behind 1 Remove three hooks to release and hang the in take grille Hooks Back Front Loosen the screws and remove two hanging wires Tap tight screw 2 Hold the handle to lift the air filter The diagram shows the removed intake grille for explanatory purpose Handles Air Filter Release the hooks Air Filter Side view Back Front 3 Remove three h...

Страница 6: ...ps When IR Receiver is installed The OPERATION indicator lamp green flashes An oil recovery operation is being performed See page 3 The OPERATION indicator lamp green flashes An automatic defrosting operation is being per formed See page 3 The OPERATION indicator lamp green and TIMER indicator lamp orange are flashing alternately It has recovered from a power outage The OPERATION indicator lamp gr...

Страница 7: ...erature and use it Tem perature may not fall down depending on the room conditions While high humidity or the room temperature is high See page 3 In the following situations stop operation immediately and get in touch with authorized service personnel The problem cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is flashing very fast When IR Re...

Страница 8: ...9383490019_OM_AR indd 7 9383490019_OM_AR indd 7 05 02 2019 18 30 47 05 02 2019 18 30 47 ...