TROUBLESHOOTING

The following conditions are not breakdowns or operation failures.

Symptom

Problem

See page

Doesn’t operate immediately:

If the unit is stopped and then immediately started again, the compressor will not operate for about 

 

3 minutes, in order to prevent fuse blowouts.

Whenever the electrical breaker is turned off then on again, the protection circuit will operate for 

 

about 3 minutes, preventing unit operation during that period.

Air

fl

 ow is weak or stops:

When Heating operation is started, indoor unit’s fan may temporarily stop, to allow internal parts to 

 

warm up.

During Heating operation, if the room temperature rises above the thermostat setting, the outdoor 

 

unit will stop, and the indoor unit’s fan will stop. If you wish to warm the room further, set the ther-
mostat for a higher setting.

During oil recovery operation, the air 

fl

 ow may stop for approximately 10 minutes.

 

3

During Heating operation, the unit will temporarily stop operation (between 4 and 15 minutes) as 

 

the Automatic Defrosting mode operates.

3

The fan may operate at low speed during Dry operation or when the unit is monitoring the room’s 

 

temperature.

In the monitor AUTO operation, the fan will operate at low speed.

 

Flashing lamps:
(Limited to only when receiver 
unit is connected)

The Operation indicator lamp 
(green) 

fl

 ashes:

An oil recovery operation is being performed.

3

The Operation indicator lamp 
(green) 

fl

 ashes:

An automatic defrosting operation is being performed.

3

The Operation indicator lamp 
(green) and Timer indicator lamp 
(orange) are 

fl

 ashing alternately: 

It has recovered from a power outage.

The Operation indicator lamp 
(green) and Timer indicator lamp 
(orange) are 

fl

 ashing simultane-

ously: 

It is operating in trial operation mode.
Ask a manager as there may be maintenance being conducted.

The Operation indicator lamp 
(green) lights up and the Timer 
indicator lamp (orange) 

fl

 ashes:

This is the standby state.

3

Noise is heard:

In the following conditions there are sounds of water 

fl

 owing from the indoor unit and the operation 

 

sound becomes loud. These are the sounds of the 

fl

 owing of refrigerant.

 When operation starts 
When oil recovery operation 

fi

 nishes 

When automatic defrosting operation 

fi

 nishes

During operation, a slight squeaking sound may be heard. This is the result of minute expansion 

 

and contraction of the panel due to temperature changes.

During Heating operation, a sizzling sound may be heard occasionally. This sound is produced by 

 

the Automatic Defrosting operation.

3

Smells:

Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, 

 

tobacco, etc.) which have been taken into the air conditioner.

Fog comes out of the indoor unit:

During Cooling operation, a thin mist may be seen emitted from the indoor unit. This results from 

 

the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation 
and misting.

Steam comes out of the indoor 
unit:

During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the 

 

unit. This is due to the Automatic Defrosting operation.

3

Water is produced from the 
outdoor unit:

During Heating operation, water may be produced from the outdoor unit due to the Automatic 

 

Defrosting operation.

9374343126-01_OM.indb   4

9374343126-01_OM.indb   4

2012-6-15   9:13:05

2012-6-15   9:13:05

Содержание AIRSTAGE ARXB07GALH

Страница 1: ...rde este manual para consulta futura BEDIENUNGSANLEITUNG INNENGERÄT Kanaltyp Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo a condotto Conservare questo manuale per consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος αγωγού Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Короб ...

Страница 2: ...condi tioner or the air filter Do not pour water or cleaning solvent on the unit directly or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy press...

Страница 3: ...d CAUTION Do not press the MANUAL AUTO button with wet hands or pointed ob jects otherwise an electric shock or malfunction may occur Starting Operation Press the MANUAL AUTO button on the operating control panel The operation can be set in the following setting Operating mode AUTO When Auto mode cannot be selected it will operate in the same mode as the other indoor unit in the same system When o...

Страница 4: ...ing mode are limited Cooling priority state When the other indoor units within the same system operate in cooling or dry mode heating can not be selected at the same time Heating priority state When the other indoor units within the same system operate in heating mode cooling and dry mode can not be selected at the same time Standby state The standby state activates when 2 or more indoor units sta...

Страница 5: ...as recovered from a power outage The Operation indicator lamp green and Timer indicator lamp orange are flashing simultane ously It is operating in trial operation mode Ask a manager as there may be maintenance being conducted The Operation indicator lamp green lights up and the Timer indicator lamp orange flashes This is the standby state 3 Noise is heard In the following conditions there are sou...

Страница 6: ...r Close the curtains In the case of Cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the fan speed set to low Set the temperature lower than the room temperature and use it Temperature does not fall down well Temperature may not fall down depending on the room conditions While high humidity or the room temperature is high 3 In ...

Страница 7: ... 1 and ISO 3744 Standard static pressure 25 Pa MODEL ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH POWER SOURCE 230 V 50 Hz AVAILABLE VOLTAGE RANGE 198 to 264 V COOLING CAPACITY kW 2 2 2 8 3 6 4 5 5 6 7 1 HEATING CAPACITY kW 2 8 3 2 4 0 5 0 6 3 8 0 SOUND PRESSURE LEVEL HIGH dB A 28 29 30 34 34 35 MED dB A 25 26 27 32 32 32 LOW dB A 22 24 24 28 28 29 DIMENSIONS WEIGHT HEIGHT mm ...

Страница 8: ...gen Gießen Sie kein Wasser oder Reinigungslösungen direkt auf das Gerät und waschen Sie das Gerät nicht damit ab Setzen Sie die Klimaanlage keiner direkten Einwirkung von Wasser aus Betätigen Sie die Klimaanlage nicht mit feuchten Händen Installationsunterbau der Klimaanlage auf Beschädigung überprüfen Nur mit installierten Luftfiltern betreiben Trinken Sie nicht das abgelassene Wasser der Klimaan...

Страница 9: ...ossen wurde VORSICHT Drücken Sie nicht mit nassen Händen oder spitzen Objekten auf die Taste MANUAL AUTO sonst kann es zu einem elektrischen Schlag oder zu Fehlfunktionen kommen Betrieb starten Drücken Sie die Taste MANUAL AUTO auf dem Bedie nungsfeld Der Betrieb kann mit der folgenden Einstellung eingestellt werden Betriebsmodus AUTO Wenn der Auto Modus nicht ausgewählt werden kann funktioniert e...

Страница 10: ...ftsstatus Es können mehrere Innengeräte innerhalb des gleichen Systems verbunden werden Je nach System ist die Auswahl der Betriebsmodi begrenzt Kühlen Priori tätsstatus Wenn die Innengeräte innerhalb des gleichen Systems im Kühl oder Trocknungsmodus betrieben werden kann nicht gleichzeitig Heizen ausgewählt werden Heizen Priori tätsstatus Wenn die Innengeräte innerhalb des gleichen Systems im Hei...

Страница 11: ... die Timer Anzeigelampe orange blinken abwechselnd auf Es wurde nach einem Stromausfall wieder hergestellt Die Operation Anzeigelampe grün und die Timer Anzeigelampe orange blinken gleichzeitig auf Es arbeitet im Versuchsbetriebsmodus Fragen Sie einen Manager da eventuell eine Wartung durch geführt wird Nun leuchtet die Operation Anzei gelampe grün auf und die Timer Anzeigelampe orange blinkt Dies...

Страница 12: ...ie Vor hänge Bei Kühlbetrieb Befinden Sie Heizgeräte und Computer im Raum oder sind zu viele Menschen im Raum Ist die Lüftergeschwindigkeit zu niedrig Stellen Sie die Temperatur niedri ger ein als die Raumtemperatur ist und verwenden Sie es Temperatur sinkt nicht gut ab Je nach Raumbedingung kann es sein dass die Temperatur nicht abfällt Bei hoher Feuchtigkeit oder wenn die Temperatur sehr hoch is...

Страница 13: ...1 und ISO 3744 Standard statischer Druck 25 Pa MODELL ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH STROMQUELLE 230 V 50 Hz VERFÜGBARER SPANNUNGSBEREICH 198 bis 264 V KÜHLKAPAZITÄT kW 2 2 2 8 3 6 4 5 5 6 7 1 HEIZKAPAZITÄT kW 2 8 3 2 4 0 5 0 6 3 8 0 SCHALLDRUCKPEGEL HOCH dB A 28 29 30 34 34 35 MITTEL dB A 25 26 27 32 32 32 NIEDRIG dB A 22 24 24 28 28 29 MAßE GEWICHT HÖHE mm 198 ...

Отзывы: