background image

En-1

SAFETY PRECAUTIONS

Before using the appliance, read these “PRECAUTIONS” thoroughly 

 

and operate in the correct way.
The instructions in this section all relate to safety; be sure to maintain 

 

safe operating conditions.
“WARNING” and “CAUTION” have the following meanings in these 

 

instructions:

 WARNING

This mark indicates procedures which, if im-
properly performed, might lead to the death or 
serious injury of the user.

 CAUTION

This mark indicates procedures which, if im-
properly performed, might possibly result in per-
sonal harm to the user, or damage to property.

PRECAUTIONS ON USE

 WARNING

Do not keep exposing oneself to the direct wind of air conditioner for a 

 

long time.
Do not insert 

fi

 ngers or objects into the outlet port or intake grilles.

 

Except for EMERGENCY, never turn off main as well as sub breaker 

 

of the indoor units during operation. It will cause compressor failure as 
well as water leakage. First, stop the indoor unit by operating the con-
trol unit, converter or external input device and then cut the breaker. 
Make sure to operate through the control unit, converter or external 
input device.
If the power supply cord of this appliance is damaged, it should only 

 

be replaced by the authorized service personal, since special purpose 
tools and speci

fi

 ed cord are required.

If any refrigerant happens to leak, extinguish any 

fl

 ames, ventilate the 

 

room and get in touch with authorized service personnel.

 CAUTION

Do not place animals or plants in the direct path of the air 

fl

 ow.

 

Do not direct air

fl

 ow at 

fi

 replaces or heating apparatus.

 

Do not block or cover the inlet port and outlet port.

 

Do not climb on, or place objects on, the air conditioner.

 

Do not set 

fl

 ower vases or water containers on top of air conditioners.

 

Do not hang objects from the indoor unit.

 

Do not place anything below the indoor unit that should not get wet.

 

Always turn off the electrical breaker whenever cleaning the air condi-

 

tioner or the air 

fi

 lter.

Do not pour water or cleaning solvent on the unit directly, or wash the 

 

unit with them.
Do not expose the air conditioner directly to water.

 

Do not operate the air conditioner with wet hands.

 

Check the condition of the installation stand for damage.

 

Operate only with air 

fi

 lters installed.

 

Do not drink the water drained from the air conditioner.

 

Do not apply any heavy pressure to radiator 

fi

 ns.

 

Do not use in

fl

 ammable gases near the air conditioner.

 

Do not touch the piping during operation.

 

Ensure that any electronic equipment is at least 1m away from either 

 

the indoor or outdoor units.
This appliance is not intended for use by persons (including children) 

 

with reduced physical, sensory or mental capabilities, or lack of ex-
perience and knowledge, unless they have been given supervision or 
instruction concerning use of the appliance by a person responsible for 
their safety. Children should be supervised to ensure that they do not 
play with the appliance.

Note:

  Switching the operating mode in the heat recovery system may 

require some time to prepare for operation. Please note that this is 
not a fault.

PRECAUTIONS ON INSTALLATION

 CAUTION

Do not attempt to install this air conditioner by yourself.

 

This unit contains no user-serviceable parts. Always consult authorized 

 

service personnel for repairs.
When moving, consult authorized service personnel for disconnection 

 

and installation of the unit.
The unit must be earthed (grounded).

 

Make sure drain work is implemented properly for drainage.

 

Avoid installing the air conditioner near a 

fi

 replace or other heating 

 

apparatus.
When installing the indoor and outdoor units, take precautions to pre-

 

vent access by infants.

NAME OF PARTS

ARXB 07/09/12/14/18

 Ceiling Concealed

 Floor Standing Concealed

1

 Outlet Port

2

 Intake Port

CONTENTS

SAFETY PRECAUTIONS ........................................................................1
NAME OF PARTS ...................................................................................1
MANUAL AUTO OPERATION ................................................................2
OPERATING TIPS ..................................................................................3
CLEANING AND CARE...........................................................................3
TROUBLESHOOTING ............................................................................4
SPECIFICATIONS ...................................................................................6

OPERATING MANUAL

PART NO. 9374343126
VRF system indoor unit (Duct type)

9374343126-01_OM.indb   1

9374343126-01_OM.indb   1

2012-6-15   9:12:56

2012-6-15   9:12:56

Содержание AIRSTAGE ARXB07GALH

Страница 1: ...rde este manual para consulta futura BEDIENUNGSANLEITUNG INNENGERÄT Kanaltyp Bewahren Sie dieses Handbuch für eine spätere Bezugnahme auf MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo a condotto Conservare questo manuale per consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος αγωγού Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ Короб ...

Страница 2: ...condi tioner or the air filter Do not pour water or cleaning solvent on the unit directly or wash the unit with them Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Check the condition of the installation stand for damage Operate only with air filters installed Do not drink the water drained from the air conditioner Do not apply any heavy press...

Страница 3: ...d CAUTION Do not press the MANUAL AUTO button with wet hands or pointed ob jects otherwise an electric shock or malfunction may occur Starting Operation Press the MANUAL AUTO button on the operating control panel The operation can be set in the following setting Operating mode AUTO When Auto mode cannot be selected it will operate in the same mode as the other indoor unit in the same system When o...

Страница 4: ...ing mode are limited Cooling priority state When the other indoor units within the same system operate in cooling or dry mode heating can not be selected at the same time Heating priority state When the other indoor units within the same system operate in heating mode cooling and dry mode can not be selected at the same time Standby state The standby state activates when 2 or more indoor units sta...

Страница 5: ...as recovered from a power outage The Operation indicator lamp green and Timer indicator lamp orange are flashing simultane ously It is operating in trial operation mode Ask a manager as there may be maintenance being conducted The Operation indicator lamp green lights up and the Timer indicator lamp orange flashes This is the standby state 3 Noise is heard In the following conditions there are sou...

Страница 6: ...r Close the curtains In the case of Cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the fan speed set to low Set the temperature lower than the room temperature and use it Temperature does not fall down well Temperature may not fall down depending on the room conditions While high humidity or the room temperature is high 3 In ...

Страница 7: ... 1 and ISO 3744 Standard static pressure 25 Pa MODEL ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH POWER SOURCE 230 V 50 Hz AVAILABLE VOLTAGE RANGE 198 to 264 V COOLING CAPACITY kW 2 2 2 8 3 6 4 5 5 6 7 1 HEATING CAPACITY kW 2 8 3 2 4 0 5 0 6 3 8 0 SOUND PRESSURE LEVEL HIGH dB A 28 29 30 34 34 35 MED dB A 25 26 27 32 32 32 LOW dB A 22 24 24 28 28 29 DIMENSIONS WEIGHT HEIGHT mm ...

Страница 8: ...gen Gießen Sie kein Wasser oder Reinigungslösungen direkt auf das Gerät und waschen Sie das Gerät nicht damit ab Setzen Sie die Klimaanlage keiner direkten Einwirkung von Wasser aus Betätigen Sie die Klimaanlage nicht mit feuchten Händen Installationsunterbau der Klimaanlage auf Beschädigung überprüfen Nur mit installierten Luftfiltern betreiben Trinken Sie nicht das abgelassene Wasser der Klimaan...

Страница 9: ...ossen wurde VORSICHT Drücken Sie nicht mit nassen Händen oder spitzen Objekten auf die Taste MANUAL AUTO sonst kann es zu einem elektrischen Schlag oder zu Fehlfunktionen kommen Betrieb starten Drücken Sie die Taste MANUAL AUTO auf dem Bedie nungsfeld Der Betrieb kann mit der folgenden Einstellung eingestellt werden Betriebsmodus AUTO Wenn der Auto Modus nicht ausgewählt werden kann funktioniert e...

Страница 10: ...ftsstatus Es können mehrere Innengeräte innerhalb des gleichen Systems verbunden werden Je nach System ist die Auswahl der Betriebsmodi begrenzt Kühlen Priori tätsstatus Wenn die Innengeräte innerhalb des gleichen Systems im Kühl oder Trocknungsmodus betrieben werden kann nicht gleichzeitig Heizen ausgewählt werden Heizen Priori tätsstatus Wenn die Innengeräte innerhalb des gleichen Systems im Hei...

Страница 11: ... die Timer Anzeigelampe orange blinken abwechselnd auf Es wurde nach einem Stromausfall wieder hergestellt Die Operation Anzeigelampe grün und die Timer Anzeigelampe orange blinken gleichzeitig auf Es arbeitet im Versuchsbetriebsmodus Fragen Sie einen Manager da eventuell eine Wartung durch geführt wird Nun leuchtet die Operation Anzei gelampe grün auf und die Timer Anzeigelampe orange blinkt Dies...

Страница 12: ...ie Vor hänge Bei Kühlbetrieb Befinden Sie Heizgeräte und Computer im Raum oder sind zu viele Menschen im Raum Ist die Lüftergeschwindigkeit zu niedrig Stellen Sie die Temperatur niedri ger ein als die Raumtemperatur ist und verwenden Sie es Temperatur sinkt nicht gut ab Je nach Raumbedingung kann es sein dass die Temperatur nicht abfällt Bei hoher Feuchtigkeit oder wenn die Temperatur sehr hoch is...

Страница 13: ...1 und ISO 3744 Standard statischer Druck 25 Pa MODELL ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH STROMQUELLE 230 V 50 Hz VERFÜGBARER SPANNUNGSBEREICH 198 bis 264 V KÜHLKAPAZITÄT kW 2 2 2 8 3 6 4 5 5 6 7 1 HEIZKAPAZITÄT kW 2 8 3 2 4 0 5 0 6 3 8 0 SCHALLDRUCKPEGEL HOCH dB A 28 29 30 34 34 35 MITTEL dB A 25 26 27 32 32 32 NIEDRIG dB A 22 24 24 28 28 29 MAßE GEWICHT HÖHE mm 198 ...

Отзывы: