background image

En-2

CONNECTION PIPE REQUIREMENT

 WARNING

Do not use the existing (for R22) piping and fl are nuts.

•  If the existing materials are used, the pressure inside the refrigerant cycle will rise 

and cause failure, injury, etc. (Use the special R410A materials.)

When installing and relocating the air conditioner, do not mix gases other than the 
specifi ed refrigerant (R410A) to enter the refrigerant cycle.

•  If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise 

to an abnormally high value and cause failure, injury, etc.

1]

1

2.3.  For authorized service personnel only.

 WARNING

For the air conditioner to operate satisfactorily, install it as outlined in this installation 
manual.

Connect the indoor unit and outdoor unit or branch box with the air conditioner piping 
and cables available from your local distributor. This installation manual describes the 
correct connections using the installation set available from your local distributor.

Installation work must be performed in accordance with national wiring standards by 
authorized personnel only.

Do not turn on the power until all installation work is complete.

 CAUTION

This installation manual describes how to install the indoor unit only.
To install the outdoor unit, refer to the installation manual included with the outdoor unit 
or branch box.

 

Be careful not to scratch the air conditioner when handling it.

  After installation, explain correct operation to the customer, using the operating 

manual.

1]

1

2.4. Accessories

The following installation accessories are supplied. Use them as required.

Name and Shape

Q’ty

Name and Shape

Q’ty

Operating Manual

1

Remote 
controller 
holder

1

Installation Manual 
(This manual)

1

Cloth tape

1

Wall hook bracket

1

Tapping screw 
(M4 × 25 mm)

9

Remote 
controller

1

Tapping screw 
(M3 × 12 mm)

2

Battery

Air cleaning filter

2

The following items are necessary to install this air conditioner. (The items are not 
included with the air conditioner and must be purchased separately.)

Name

Q’ty

Name

Q’ty

Connection pipe assembly

1

Wall cap

1

Connection cable (4-conductor)

1

Saddle

1 set

Wall pipe

1

Drain hose

1

Decorative tape

1

Tapping screws

1 set

Vinyl tape

1

Sealant

1

1

2.5. Optional parts

Refer to each installation manual for the method of installing optional parts.

Parts name

Model No.

Application

Wired Remote Controller

UTY-RNN

¿

M

For air conditioner operation

Simple Remote Controller

UTY-RSN

¿

M

For air conditioner operation

External connect kit

UTY-XWZX

For control input/output port

3. GENERAL

This INSTALLATION MANUAL briefl y outlines where and how to install the air conditioning 
system. Please read over the entire set of instructions for the indoor and outdoor units and 
make sure all accessory parts listed are with the system before beginning.

]1

3.1.  Type of copper pipe and insulation material

 CAUTION

Refer to the installation manual for the outdoor unit for description of allowable pipe 
length and height difference.

MODEL

Diameter

Liquid pipe

Gas pipe

9,000 Btu/h model

6.35 mm (1/4 in.)

9.52 mm (3/8 in.)

12,000 Btu/h model

6.35 mm (1/4 in.) 

9.52 mm (3/8 in.)

14,000 Btu/h model

6.35 mm (1/4 in.)

12.70 mm (1/2 in.)

 CAUTION

Install heat insulation around both the gas and liquid pipes. Failure to do so may 
cause water leaks.
Use heat insulation with heat resistance above 120 °C. Reverse cycle model only.
In addition, if the humidity level at the installation location of the refrigerant piping is 
expected to exceed 70%, install heat insulation around the refrigerant piping. If the 
expected humidity level is 70-80%, use heat insulation that is 15 mm or thicker and if 
the expected humidity exceeds 80%, use heat insulation that is 20 mm or thicker.
If heat insulation is used that is not as thick as specifi ed, condensation may form on 
the surface of the insulation. In addition, use heat insulation with heat conductivity of 
0.045 W/(m•K) or less (at 20 °C).

]1

3.2.  Additional materials required for installation

A. Refrigeration (armored) tape
B.  Insulated staples or clamps for connecting wire (See your local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping

]

1

4. ELECTRICAL REQUIREMENT

The indoor unit is powered from the outdoor unit or branch box. Do not power indoor unit 
from separate power source.

 WARNING

Refer to local codes for acceptable cable type.

Cable

Type

Remarks

Connection cable

Type 60245 IEC57

3 cable + Earth (Ground), 1 Ø 230V

Max. Cable Length: Limit voltage drop to less than 2%. Increase cable gauge if voltage 
drop is 2% or more.

5.  SELECTING THE MOUNTING POSITION

Decide the mounting position with the customer as follows:
(1)  Install the indoor unit level on a strong wall which is not subject to vibration.
(2)  The inlet and outlet ports should not be obstructed: the air should be able to blow all 

over the room.

(3)  Install the unit a dedicated electrical branch circuit.
(4)  Do not install the unit where it will be exposed to direct sunlight.
(5)  Install the unit where connection to the outdoor unit or branch box is easy.
(6)  Install the unit where the drain pipe can be easily installed.
(7)  Take servicing, etc. into consideration and leave the spaces shown in the figure. Also 

install the unit where the filter can be removed.

Correct initial installation location is important because it is diffi cult to move unit after it is 
installed.

9378533028-03_IM.indb   2

9378533028-03_IM.indb   2

2011-10-08   11:08:37

2011-10-08   11:08:37

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание agyg09lvca

Страница 1: ...l autorizado MANUALE D INSTALLAZIONE Ad uso esclusivo del personale autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ Για εξουσιοδοτημένο προσωπικό σέρβις MANUAL DE INSTALAÇÃO Apenas para técnicos autorizados РУКОВОДСТВО ПО УСТАНОВКЕ Для уполномоченного персонала KURULUM KILAVUZU Yetkili servis personeli içindir AIR CONDITIONER INDOOR UNIT Floor Type PART NO 9378533028 03 9378533028 03_IM indb 1 9378533028 03_I...

Страница 2: ...pecially when replacing a conventional refrigerant R22 model with a new refrigerant R410A model always replace the conventional piping and flare nuts with the R410A piping and flare nuts Models that use refrigerant R410A have a different charging port thread diameter to prevent erroneous charging with conventional refrigerant R22 and for safety Therefore check beforehand The charging port thread d...

Страница 3: ...he entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning 1 3 1 Type of copper pipe and insulation material CAUTION Refer to the installation manual for the outdoor unit for description of allowable pipe length and height difference MODEL Diameter Liquid pipe Gas pipe 9 000 Btu h model 6 35 mm 1 4 in 9 52 mm 3 8 in ...

Страница 4: ...the upper or lower air outlet is blocked the air conditioner will not be able to cool or warm the room well Do not block the receiver with the grating Otherwise the grating will interfere with the remote controller signal and significantly reduce the distance and area angle from which the signals can be received Use a grating with vertical bars etc that has at least 75 open area If the grating has...

Страница 5: ...ccording to the direction of piping Rear piping Left piping Center of wall holl 130 mm Floor 280 mm 245 mm Back wall 100 mm Back wall 690 mm Right piping 30 mm Back wall 6 6 Note on drain hose CAUTION Insert drain hose and drain cap securely Drain should slope down to avoid water leakage When inserting be sure not to attach any material besides water If any other material is attached it will cause...

Страница 6: ...rm the flare processing with a flare tool Use the special R410A flare tool or the conventional flare tool Leakage of refrigerant may result if other flare nuts are used 4 Protect the pipes by pinching them or with tape to prevent dust dirt or water from entering the pipes L Check if L is flared uniformly and is not cracked or scratched Pipe Die Pipe outside diameter mm in Dimension A mm Dimension ...

Страница 7: ...e tool so that the wires do not come loose Strip 10 mm Sleeve Crimp type terminal 3 Use the specified wires connect them securely and fasten them so that there is no stress placed on the terminals 4 Use an appropriate screwdriver to tighten the terminal screws Do not use a screwdriver that is too small otherwise the screw heads may be damaged and prevent the screws from being properly tightened 5 ...

Страница 8: ...supply Insulated connection Check the following GOOD NO GOOD NO GOOD Accumulated drain water No upward slope 50 mm or less from earth ground Stopping downward No upward slope End of drain hose is immersed in water Drainage channel Air NO GOOD NO GOOD NO GOOD 9 TEST RUN WARNING Do not turn on the power until all installation work is complete CAUTION When restarting after a long period of disuse in ...

Страница 9: ...mode STEP 1 Selecting the Remote Controller Signal Code Use the following steps to select the signal code of the remote controller Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code The signal codes that are set through this process are applicable only to the signals in the FUNCTION SETTING For details on how to set the signal cod...

Страница 10: ...ption Function Number Setting Value Yes 40 00 No 01 Auto restart is an emergency function such as for power failure etc Do not start and stop the indoor unit by this function in normal operation Be sure to operate by the control unit or external input device Indoor room temperature sensor switching function Only for Wired remote controller The following settings are needed when using the Wired rem...

Страница 11: ...ter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputers communication error 7 1 Discharge temp sensor error 7 2 Compressor temp sensor error 7 3 Outdoor unit Heat Ex liquid temp sensor error 7 4 Outdoor temp sensor error 7 5 Suction Gas temp sensor error 7 6 2 way valve temp sensor error 3 way valve temp sensor error 7 7 Heat sink temp sensor e...

Отзывы: