7. Capacity compensation rate for pipe length and height
difference
Height difference H
Indoor unit is higher than outdoor unit
*
1
Indoor unit is lower than outdoor unit
*
2
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
H
H
7-1. Model: AOYG14KBTA2
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
¢
Indoor unit: 7,000 Btu/h
Cooling
Pipe length
m
2.5
5
10
15
20
Height difference H (m)
Indoor unit is higher than outdoor
unit *1
15
—
—
—
0.936
0.908
10
—
—
0.969
0.943
0.915
5
—
0.991
0.976
0.950
0.921
2.5
0.993
0.993
0.978
0.952
0.923
0
1.000
1.000
0.985
0.959
0.930
Indoor unit is lower than outdoor
unit *2
-2.5
1.000
1.000
0.985
0.959
0.930
-5
—
1.000
0.985
0.959
0.930
-10
—
—
0.985
0.959
0.930
-15
—
—
—
0.959
0.930
Heating
Pipe length
m
2.5
5
10
15
20
Height difference H (m)
Indoor unit is higher than outdoor
unit *1
15
—
—
—
0.937
0.915
10
—
—
0.956
0.937
0.915
5
—
1.000
0.956
0.937
0.915
2.5
0.990
1.000
0.956
0.937
0.915
0
0.990
1.000
0.956
0.937
0.915
Indoor unit is lower than outdoor
unit *2
-2.5
0.986
0.996
0.952
0.933
0.911
-5
—
0.994
0.950
0.931
0.909
-10
—
—
0.946
0.928
0.906
-15
—
—
—
0.923
0.901
- 279 -
7-1. Model: AOYG14KBTA2
7. Capacity compensation rate for pipe length and height difference
OUTDOOR UNIT
AOYG14-18KBTA2
OUTDOOR UNIT
AOYG14-18KBTA2