6. Capacity table
6-1. Combinations
¢
Model: AOYG14KBTA2
Cooling
Combination of indoor
unit
Rated capacity for
each indoor unit
(kW)
Total capacity
(kW)
Input power (kW)
EER
(W/W)
Seasonal data
Unit
Total
Unit
Min.
Rated
Max.
Min.
Rated
Max.
Pdesign
(kW)
SEER
(kWh/kWh)
Energy effi-
ciency class
1
2
1
2
7
7
14
2.00
2.00
1.4
4.00
4.6
0.25
0.97
1.20
4.12
4.0
8.7
A+++
7
9
16
1.75
2.25
1.4
4.00
4.6
0.25
0.97
1.20
4.12
4.0
8.7
A+++
7
12
19
1.47
2.53
1.4
4.00
4.6
0.25
0.97
1.20
4.12
4.0
8.7
A+++
9
9
18
2.00
2.00
1.4
4.00
4.6
0.25
0.97
1.20
4.12
4.0
8.7
A+++
9
12
21
1.71
2.29
1.4
4.00
4.6
0.25
0.97
1.20
4.12
4.0
8.7
A+++
NOTES:
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h
• The above is the value for connecting with KG models in wall mounted type.
• 2 or more indoor units should be connected.
• Cooling: Indoor temperature of 27 °CDB/19 °CWB and outdoor temperature of 35 °CDB.
• Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
• The total ability of connected indoor unit is from 14,000 Btu/h up to 21,000 Btu/h.
Heating
Combination of indoor
unit
Rated capacity for
each indoor unit (kB-
tu/h)
Total capacity
(kBtu/h)
Input power (kW)
COP
(W/W)
Seasonal data
Unit
Total
Unit
Min.
Rated
Max.
Min.
Rated
Max.
Pdesign
(kW)
SCOP
(kWh/kWh)
Energy effi-
ciency class
1
2
1
2
7
7
14
2.20
2.20
1.1
4.40
5.5
0.25
0.95
1.65
4.63
3.5
4.7
A++
7
9
16
1.92
2.48
1.1
4.40
5.5
0.25
0.95
1.65
4.63
3.5
4.7
A++
7
12
19
1.62
2.78
1.1
4.40
5.5
0.25
0.95
1.65
4.63
3.5
4.7
A++
9
9
18
2.20
2.20
1.1
4.40
5.5
0.25
0.95
1.65
4.63
3.5
4.7
A++
9
12
21
1.89
2.51
1.1
4.40
5.5
0.25
0.95
1.65
4.63
3.5
4.7
A++
NOTES:
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h
• The above is the value for connecting with KG models in wall mounted type.
• 2 or more indoor units should be connected.
• Heating: Indoor temperature of 20 °CDB, and outdoor temperature of 7 °CDB/6 °CWB.
• Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
• The total ability of connected indoor unit is from 14,000 Btu/h up to 21,000 Btu/h.
- 243 -
6-1. Combinations
6. Capacity table
OUTDOOR UNIT
AOYG14-18KBTA2
OUTDOOR UNIT
AOYG14-18KBTA2