ELECTRIC CHARACTERISTICS
9.
Model name
AO
G09LVCN
AO
G12LVCN
AO
G14LVCN
Power supply
Voltage
V
230 ~
Frequency
Hz
50
*1) Max operating current
A
11.5
14.5
Starting Current
A
3.9
5.6
6.5
*2) Wiring Spec.:
Main Fuse (Circuit breaker)
Current
A
15
20
Power Cable
mm
2
1.5
3.5-4.0
*3) Limited wiring length :
m
13
21
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.:
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*3) Limited wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.