EXTERNAL OUTPUT
11-2.
OPERATION STATUS OUTPUT
An air conditioner operation status signal can be output.
Circuit diagram example
z
Relay spec.:
Max.24V DC, 10mA to less
than 500mA.
Field supply
Ex.)Display
Indoor unit
control PC board
Connected unit
Ex.)Relay unit
1
2
Signal
Relay
power
supply
V
Connector
10m*
24V DC
* Make the distance from the PC board to the connected unit within 10m.
ON
OFF
Operation
Stop
Indoor unit
Output signal
Parts (Optional)
z
Parts name
Model name
External connect kit
UTY-XWZXZ5
Wire (External output) : UTY-XWZXZ5