- (01 - 21) -
FL
OO
R T
YP
E
A
G
G
09
-1
4LV
C
A
FL
OO
R T
YP
E
A
G
G
09
-1
4LV
C
A
EXTERNAL OUTPUT
11-2.
OPERATION STATUS OUTPUT
An air conditioner operation status signal can be output.
Circuit diagram example
z
Relay spec.:
Max.DC 24 V, 10 mA to less
than 500 mA.
Field supply
Ex.) Display
Indoor unit
control PC board
Connected unit
Ex.) Relay unit
1
2
Signal
Relay
power
supply
V
Connector
10 m*
DC 24 V
* Make the distance from the PC board to the connected unit within 10 m.
ON
OFF
Operation
Stop
Indoor unit
Output signal
Parts (Optional)
z
Parts name
Model name
External connect kit
UTY-XWZX