CLEANING AND CARE

Cleaning the Air Filter

  Before cleaning the unit, be sure to stop the unit and disconnect the power supply.
  Turn off the electrical breaker.
  A fan operates at high speed inside the unit, and personal injury could result.

  When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit 

be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.

  When cleaning the unit’s body, do not use water hotter than 40°C, harsh abrasive cleansers, or volatile agents like benzene or 

thinner.

  Do not expose the unit body to liquid insecticides or hair sprays.
  If the unit will not be operated for a period of 1 month or more, be sure to allow the inner parts of the unit to dry thoroughly, in 

advance, by operating the unit in fan mode for half a day.

 

Remove the dust from the air 

fi

 lters by vacuuming or washing them. After washing, allow the air 

fi

 lters to dry thoroughly 

in an area protected from sunlight.

 

Dust can be cleaned from the air 

fi

 lter either with a vacuum cleaner, or by washing the 

fi

 lter in a solution of mild deter-

gent and warm water. If you wash the 

fi

 lter, be sure to allow it to dry thoroughly in a shady place before reinstalling.

 

If dirt is allowed to accumulate on the air 

fi

 lter, air 

fl

 ow will be reduced, lowering operating ef

fi

 ciency and increasing 

noise.

CAUTION

ECONOMY OPERATION

Begin air conditioner operation before performing this procedure.

To Use the ECONOMY Operation

Press the ECONOMY button.

The ECONOMY indicator will light.
ECONOMY operation begins.

To Stop the ECONOMY Operation

Press the ECONOMY button again.

The ECONOMY indicator will go out.
Normal operation begins.

About ECONOMY Operation

At the maximum output, ECONOMY operation is approximately 70% of normal air conditioner operation for cooling and heating.

  If the room is not cooled (or heated) well during ECONOMY operation, select normal operation.
  During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY operation even if 

ECONOMY operation is selected by pressing the ECONOMY operation button.

  When ECONOMY operation mode is operated, the room temperature will be little higher than the set-temp under cooling mode 

and lower than set-temp under heating mode. Therefore, the ECONOMY mode is able to save more energy than other normal 
mode.

  In case of multi-type air conditioner, the ECONOMY operation mode is only available for the set indoor unit.

  

Can be used if set correctly during installation. Please consult authorized service personnel when using this 

function.

•  It lights on when it is time to clean the air 

fi

 lters.

After turning the power on.
Press the MAINTENANCE button for 
2 seconds or more on the remote control.
The 

fi

 lter indicator will disappear.

Filter indicator Reset (A special setting)

9374379705_OM.indb   Sec1:12

9374379705_OM.indb   Sec1:12

6/26/2013   4:44:10 PM

6/26/2013   4:44:10 PM

Содержание ACY7UI-MI

Страница 1: ...Русский KEEP THIS MANUAL FOR FUTURE REFERENCE BEWAHREN SIE DIESES HANDBUCH ZUM SPÄTEREN NACHSCHLAGEN AUF CONSERVEZ CE MANUEL POUR RÉFÉRENCE ULTÉRIEURE CONSERVE ESTE MANUAL PARA SU FUTURA CONSULTA CONSERVARE IL PRESENTE MANUALE PER FUTURE CONSULTAZIONI ΦΥΛΑΞΤΕ ΤΟ ΕΓΧΕΙΡΙΔΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ GUARDE ESTE MANUAL PARA REFERÊNCIA FUTURA РУКОВОДСТВО ДЛЯ СПРАВОК В БУДУЩЕМ BU KILAVUZU DAHA SONRA BAŞV...

Страница 2: ...he power switch on at least 12 hours before starting the unit Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic e...

Страница 3: ...R OPTION The optional wireless remote controller can be used When you use remote controller there are following different points as compared with using wired remote controller The additional function for wireless ones SLEEP timer TIMER 10 C HEAT operation And you can use both wireless and wired remote controller si multaneously But function is limited The restricted functions for wired ones Weekly...

Страница 4: ...Operation lamp F Timer and Clock indicator G Operation mode indicator H Fan speed indicator I Operation lock indicator J Temperature indicator K Function indicator Defrost indicator Thermo sensor indicator ECONOMY indicator Vertical swing indicator 3 Filter indicator 1 1 3 These functions cannot be used Please also see the operating manual of the option when using it with options etc 1 Can be used...

Страница 5: ... to set the current time Press repeatedly to adjust the current time in 1 minute incre ments Press and hold to adjust the current time in 10 minute increments ex Monday PM11 00 Press again to end SU MO TU WE TH FR SA 1 3 5 Press the SET BACK button to switch between the 12 and 24 hour time displays 3 4 SU MO TU WE TH FR SA SU MO TU WE TH FR SA SET BACK Set the current day and time 9374379705_OM in...

Страница 6: ... to set the room temperature Press the FAN button to set the fan speed Press the ECONOMY button to start or stop ECONOMY operation For details on the function refer to page 11 To start stop operation To set the operation mode Operation mode setting Room temperature setting Fan speed setting ECONOMY operation AUTO COOL DRY FAN HEAT AUTO HIGH MED LOW QUIET Instructions relating to heating are applic...

Страница 7: ...ss the DAY DAY OFF button and TIMER SET button simul taneously for 2 seconds or more to activate the child lock func tion and lock all of the buttons on the remote controller except the START STOP button SET TEMP buttons MODE button and FAN button Press the buttons again for 2 seconds or more to deactivate the child lock function When the child lock function is activated the mark ap pears If any b...

Страница 8: ...vance ON timer See page 8 Use this timer function to start air conditioner operation The timer operates and air conditioner operation starts after the set time has passed The timer can be set up to 24 hours in advance WEEKLY timer See page 9 Use this timer function to set operating times for each day of the week Use the DAY OFF setting to switch off timed operation for a selected day in the coming...

Страница 9: ...at steps 3 and 4 To complete the weekly timer settings press the TIMER SET button for 2 seconds or more To delete the operating time If the TIMER DELETE button is pressed dur ing steps 3 or 4 the operating time for the selected day will be deleted If all the days are selected the operating times for all of the days will be deleted NOTES The operating time can be set in 30 minute increments only Th...

Страница 10: ...ures as those for setup ex The DAY OFF is set for Monday NOTES The DAY OFF setting is only available for days for which weekly settings already exist If the operating time carries over to the next day during a next day setting the effective DAY OFF range will be set as shown below Normal Next day setting The DAY OFF setting can only be set 1 time The DAY OFF setting is cancelled automatically afte...

Страница 11: ...ss the SET TEMP buttons to set the temperature The temperature setting range is the same as the range for the operation mode ex Operating time 15 00 22 00 5 Repeat steps 3 and 4 Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings To start SET BACK Press the SET BACK button The SET BACK confirmation display appears for 5 seconds and then the timer st...

Страница 12: ...iency and increasing noise CAUTION ECONOMY OPERATION Begin air conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator will go out Normal operation begins About ECONOMY Operation At the maximum output ECONO...

Страница 13: ...g from the unit This is due to the automatic defrosting operation 15 Airflow is weak or stops When heating operation is started fan speed is temporarily very low to allow internal parts to warm up During heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further ...

Страница 14: ...ttings thermostat cor rectly Is there a window or door open In the case of cooling operation is a window allowing bright sun light to enter Close the curtains In the case of cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the unit set for QUIET operation If the problem persists after performing these checks or if you notice bu...

Страница 15: ...m by recircu lating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high during use of the heating mode the outdoor unit s fan may stop at times Microcomputer controlled Automatic Defrosting When using the heating mode u...

Страница 16: ...e fan will operate at low speed for about a few minute during which time the indoor unit detects the room conditions and selects the proper operation mode Room temperature is higher than the defined temperature in temperature setting Cooling mode or dry mode Room temperature is close to the defined temperature in temperature setting Determined by outdoor temperature Room temperature is lower than ...

Страница 17: ...ry various operating patterns in order to confirm the level of heating and cooling output provided by your units and use the units in the way that best matches your family s lifestyle lf you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation we recommend that you stop simultaneous operation of the multiple units Operation cannot be done in the fo...

Страница 18: ...splayed inspection of the air conditioning system is necessary Please consult authorized service personnel Unit number usually 00 Error code ex Self diagnosis check 9374379705_OM indb Sec1 18 9374379705_OM indb Sec1 18 6 26 2013 4 44 11 PM 6 26 2013 4 44 11 PM ...

Отзывы: