TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the
power supply plug, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to disconnect the power supply plug or turn off your circuit breaker to
ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the power supply plug is disconnected and then recon-
nected to a power outlet, the protection circuit will operate for about
3 minutes, preventing unit operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a sizzling sound may be heard occa-
sional. This sound is produced by the Automatic Defrosting op-
eration.

Some smell may be emitted from the indoor unit. This smell is
the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

*

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator lamp will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

*

During Heating operation, water may be produced from the out-
door unit due to Automatic Defrosting operation.

See Page

15

15

15

6

6

15

NORMAL

FUNCTION

Содержание ABT18FB

Страница 1: ...t ABT18FB ABT18UB ABT24FB ABT24UB Outdoor Unit AOT18FN AOT18UN AOT24FN AOT24UN ROOM AIR CONDITIONER FLOOR CONSOLE UNDER CEILING DUAL TYPE OPERATING MANUAL KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED ...

Страница 2: ...ng use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not usin...

Страница 3: ...AT COOL MODEL REVERSE CYCLE When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradu ally lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTRO...

Страница 4: ...3 Fig 7 Fig 6 Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 1 Fig 3 Fig 2 Fig 4 E G F ...

Страница 5: ...dicator lamps will flash simultaneously To stop the test operation mode press the START STOP button to stop the air condi tioner V Remote Control Unit Display Fig 7 W Transmit Indicator X Clock Display Y Operating Mode Display Z Timer Mode Display Fan Speed Display Temperature Set Display Timer Set Indicator Temperature Set Indicator Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO ...

Страница 6: ...de to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the SET TIME buttons to adjust the clock to the current time button Press to advance the ...

Страница 7: ... the entire display will reappear The thermostat setting should be considered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as ...

Страница 8: ...air conditioner has adjusted your room s temperature to near the ther mostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subsequently changes the air conditioner will once again select the appropriate operation Heating Cool ing to adjust the temperature to the value set in the thermostat The monitor operation range...

Страница 9: ...STOP button To Change Operating Conditions If you wish to change the operating conditions Mode Fan Speed Thermostat Setting after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER button to select TIMER RESET The air conditioner will return to normal operation To Change the...

Страница 10: ...ooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the thermo stat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time Set tim...

Страница 11: ...be adjusted during this pe riod Horizontal Air Direction Adjustment Press the AIR FLOW DIRECTION HORIZONTAL SET button Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 The remote control unit s display does not change Use the air direction adjustments within the ranges shown above Fig 9 DANGER Never place fingers or foreign objects inside the outlet ports si...

Страница 12: ...range 5 to 7 for long periods of time since water vapor may con dense near the outlet louvers and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator lamp HORIZONTAL SWING orange will light In this mode the RIGHT LEFT air direction louvers will swing automatically to direct the airflo...

Страница 13: ...he center of the intake grille Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increas ing noise ...

Страница 14: ...st five seconds to display the current signal code initially set to 3 Press the buttons Fig 5 J to change the signal code between Match the code on the dis play to the air conditioner signal code 4 Press the MASTER CONTROL button again to return to the clock display The signal code will be changed SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE To operate only one of multiple air conditioners If no ...

Страница 15: ...action of the front cover due to temperature changes During Heating operation a sizzling sound may be heard occa sional This sound is produced by the Automatic Defrosting op eration Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitte...

Страница 16: ...ou feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated When Indoor and Outdoor Temperatur...

Страница 17: ... under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects un derneath Outdoor Unit AOT18FN AOT24FN AOT18UN AOT24UN Outdoor Temperature About 21 to 43 C About 0 to 43 C Temperature and Humidity Range COOLING DRY MODE COOLING MODELS HEAT COOL MODELS Reverse Cycle If the air conditioner is used under higher temperature conditioner...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: