FUNCTION SETTINGS
12.
INDOOR UNIT
12-1.
SWITCH POSITION
DIP-SW SETTING
Remote controller address setting
A number of indoor units can be operated at the same time using a wired remote controller.
Set the unit number of each indoor unit using the DIP switches on the indoor unit circuit board.
(See the following table.)
The DIP switches are normally set to make the unit number 00.
( . . .Factory setting)
Remote controller address
DIP switch No.
1
2
3
4
00
OFF
OFF
OFF
OFF
01
ON
OFF
OFF
OFF
02
OFF
ON
OFF
OFF
03
ON
ON
OFF
OFF
04
OFF
OFF
ON
OFF
05
ON
OFF
ON
OFF
06
OFF
ON
ON
OFF
07
ON
ON
ON
OFF
08
OFF
OFF
OFF
ON
09
ON
OFF
OFF
ON
10
OFF
ON
OFF
ON
11
ON
ON
OFF
ON
12
OFF
OFF
ON
ON
13
ON
OFF
ON
ON
14
OFF
ON
ON
ON
15
ON
ON
ON
ON
INDOOR UNIT
DIP SW
1
Remote controller address setting
2
3
4
Jumper Wire
JM1
Setting forbidden
JM2
JM3
JM3
JM2
JM1
Indoor unit Printed circuit board
MAIN PCB
Содержание AB G30LRTE Series
Страница 2: ...1 INDOOR UNIT CEILING TYPE AB G30LRTE AB G36LRTE DTR_AB037E_01 2013 02 28 ...
Страница 12: ... 01 09 CEILING TYPE AB G30 36LRTE CEILING TYPE AB G30 36LRTE WIRING DIAGRAMS 5 MODEL AB G30LRTE AB G36LRTE ...
Страница 34: ...DTR_AO135E_01 2013 02 28 SINGLE TYPE AO G30LETL AO G36LETL 2 OUTDOOR UNIT ...
Страница 39: ... 02 04 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL WIRING DIAGRAMS 4 MODEL AO G30LETL ...
Страница 40: ... 02 05 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL MODEL AO G36LETL ...
Страница 45: ... 02 10 OUTDOOR UNIT AO G30 36LETL OUTDOOR UNIT AO G30 36LETL SOUND LEVEL CHECK POINT 8 2 ...