(4) Wiring
[Heat & Cool model (Reverse cycle)]
1) Remove the cord clamp.
2) Process the end of the connection cords to the
dimensions shown in Fig. 37.
3) Connect the end of the connection cord fully into
the terminal block.
Do not remove the screws. If the stays
are removed, the electric component box
will fall.
(2) Pull out the electric component box.
Fig.35
Electric component box
Fig. 34
Electric component box
Remove the four
tapping screws.
Fig.36
Electric component box
(3) Remove the electric component box cover.
Remove the three tapping screws.
Base
Be careful not to pinch the lead wires
between the electric component box and
base.
Fig. 37
Terminal block
Connection
cord
Cord clamp
Power cord
4) Fasten the connection cord with a cord clamp.
5) Fasten the end of the connection cord with the
screw.
[Cooling model]
1) Remove the cord clamp.
2) Process the end of the connection cords to the
dimensions shown in Fig. 38.
3) Connect the end of the connection cord fully into
the terminal block.
Fig. 38
Terminal block
Connection
cord
Cord clamp
Power cord
4) Fasten the connection cord with a cord clamp.
5) Fasten the end of the connection cord with the
screw.