– 139 –
8. FINISHING
Fig. 29
Fig. 30
Overlap the insulation.
Indoor unit pipe
(heat insulation)
Vinyl tape
Bind the pipes together so
that there is no gap.
Connection pipe
(heat insulation)
Connection
pipe
Indoor unit
pipe
Wrap with cloth tape.
Cloth tape
,,
¢¢
,,,,,,,
,,,,,,,
,,,,,,,
QQQQQQQ
QQQQQQQ
QQQQQQQ
¢¢¢¢¢¢¢
¢¢¢¢¢¢¢
¢¢¢¢¢¢¢
Fig. 31
Vinyl tape
Pipe
Connection cord
,,,,,
,,,,,
,,,,,
QQQQQ
QQQQQ
QQQQQ
¢¢¢¢¢
¢¢¢¢¢
¢¢¢¢¢
,
,
Q
Q
¢
¢
Fig. 32
Left piping
Cloth tape
Pipe
Drain hose
Drain hose
Pipe
Connection cord
Wrap with cloth tape
(1) Insulate between pipes.
• For rear, right, and bottom piping, overlap the
connection pipe heat insulation and indoor unit
pipe heat insulation and bind them with vinyl tape
so that there is no gap.
• For left and left rear piping, butt the connection
pipe heat insulation and indoor unit pipe heat
insulation together and bind them with and vinyl
tape so that there is no gap.
• For left and left rear piping, wrap the area which
accommodates the rear piping housing section
with cloth tape.
• For left and left rear piping, bind the connection
cord to thetop of the pipe with vinyl tape.
• For left and left rear piping, bundle the piping and
drain hose together by wrapping them with cloth
tape over the range within which they fit into the
rear piping housing section.
(2) Temporarily fasten the connection cord along the
connection pipe with vinyl tape. (Wrap to about 1/3
the width of the tape from the bottom of the pipe so
that water does not enter.)
(3) Fasten the connection pipe to the outside wall with
a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and
the pipe with sealer so that rain water and wind can-
not blow in.
(5) Fasten the drain hose to the outside wall, etc.
Check that:
• The top and bottom hooks are hooked firmly and
the indoor unit does not move to the front and
rear or left and right.
• The indoor unit is accurately positioned horizon-
tally and vertically.
• When connected from the left rear, the drain hose
is at the bottom left of the wall pipe.
Fig. 33
Wall pipe
Connection
pipe
Connection
cord
Drain
hose
(For connection from
the left rear)
(View from indoors)
Fig. 34
Saddle
Outside wall
cap
Sealer putty
Wall
(Outdoors)
Pipe
,
,
,
,
,
,
,,
,
,,,
,,
,,
,,
,,
,,
,
Drain hose
Saddle
Lifted up
Wave
End in
water
Fig. 34
Check the following :
BAD
BAD
BAD
GOOD