– 133 –
q
w
Under cover B
Fig. 5
Removing the wall hook bracket
Remove the wall hook bracket in the following order:
q
Remove one side of under cover B by pulling it
forward (arrow direction in Fig. 5).
w
Remove the other side of under cover B by
pulling it forward (arrow direction in Fig. 5).
e
Remove the tapping screw installed to under
cover A. (Fig. 6)
r
While pulling the right side of under cover A for-
ward (releasing the inside stopper), slide under
cover A to the left and unhook the two inside
hooks. (Fig. 6)
t
Next, remove under cover A by pulling the left
side forward (arrow direction in Fig. 6).
y
Remove the four tapping screws holding the wall
hook bracket. (Fig. 7)
1. INSTALLING THE WALL HOOK BRACKET
Fig. 6
Stopper
Tapping
screw
Under cover A
Hook
e
r
t
,,,,,,
,,,,,,
Wall hook bracket
Tapping
screw
y
Fig. 7
(1) Install the wall hook bracket so that it is correctly
positioned horizontally and vertically. If the wall
hook bracket is tilted, water will drip to the floor.
(2) As the weight of the indoor unit is 37 to 44 Ibs (17 to
20 kg), it should be installed after properly examin-
ing the place where it is intended to be installed. If
the place is not strong enough, a plank or girder
should be used to make the place sufficiently strong
so that the wall can support the weight.
[Installation directly to a wall]
Before fastening the wall hook bracket to the wall with
the screws, level it by tapping the hook at the center of
bracket to the wall with the handle of a screwdriver.
• Fasten the wall hook bracket to the wall with 6 or more
screws and anchor bolts through the holes near the
outer edge of the bracket.
• Do not install the wall hook bracket at only one place
or at an angle. For a concrete wall, embed anchor bolts
(10 mm dia.) into the wall at the wall hook bracket
holes (12 x 18 mm dia.). Allow the anchor bolts to stick
out at least 18 mm from the wall.(Fig.8)
Install the unit to the anchor bolts with nuts through
the wall hook bracket. Use 2 bolts for concrete wall and
4 bolts for blister concrete wall.
• Finally tighten the bolts and wood screws after con-
firming, using the level indicator, that the clamp is hor-
izontal.
IInstall the wall hook bracket horizontally
and perpendicularly. If the wall hook
bracket is tilted, water will drip to the
floor.
,
,
598
366
216
622
628
133
219
244
373
604
24
36
76
131
186
241
315
320
57
Piping inlet
55
20-ø12x18hole
for bolt
84-ø6hole
for tapping screw
Piping
inlet
55
57
466
472
241
Wall hook bracket
23 / 32” (18 mm) max.
Wall
Bolt
Fig. 8
Anchor bolt
Wall hook bracket
Tapping screw
(big)
Fig. 9
Tapped
Hook
Hook
Center notch
String
Counter
weight
(Handle of screwdriver)
Wall hook
bracket