• For the master unit, set SW2 on ”0”. For a slave

unit, set SW2 on ”1~3”.

• A master unit is an indoor unit with the power line

connected directly from the outdoor unit.

Indoor

unit

SW2

0

1

2

3

Outdoor

unit

Master

R

Slave

Slave

Slave

q w e

q w e

q w e

q w e

q w e

q w e

q w e

q w e

q w e

S T N E

Fig. 44    [Example]

Fig. 46

9. FINISHING

(1)  Install the filter guide.

(2) Install the intake grilles.

(3) Install side covers A and B (if the unit is installed in a

half-concealed orientation, only install side cover A).

(4) Install the air filters.

10. CUSTOMER  GUIDANCE

Explain the following to the customer in accordance
with the operating manual: 

(1)  Starting and stopping method, operation switching,

temperature adjustment, timer, air flow adjustment,
and other remote controller operations.

(2) Air filter removal and cleaning.

(3) Give the operating and installation manuals to the

customer.

11. REMOTE  CONTROLLER  INSTALLATION

• Insert the end of a flat blade screwdriver at the

arrow parts of the groove at the side of the remote
controller case and remove the remote controller
case top by turning the screwdriver.

• Disconnect the remote controller cord from the

remote controller terminal board.

(1) When remote controller exposed

1) Make a notch in the thin part (

part of Fig. 45) at

the remote controller case top and bottom with
nippers, file, etc.

2) Connect the remote controller cord to the remote

controller terminal board specified in (Fig. 46).

3) Clamp the remote controller cord sheath with the

binder (small) as shown in Fig. 46.

4) Cut off the excess binder.

(2) When remote controller cord embedded

1) Embed the remote controller cord and box.

2) Pass the remote controller cord through the hole

at the remote controller case bottom and install
the cord to the box (Fig. 47).

3) Connect the remote controller cord to the remote

controller terminal board specified in (Fig. 46).

• After wiring work is complete, return the remote

controller case top to its original state.

°

C

NON STOP

CLOCK

TEMP

AUTO

TIMER
MODE

SET

START/STOP

CLOCK ADJUST

SET TIME

TEMP./DAY

FAN

CONTROL

MASTER

CONTROL

2

1

HIGH

COOL

DEFROST TEST

DAY OFF

Fig. 45

Remote controller
terminal board

Black

Red

White

Remote con-
troller cord

Binder (small)

Fig. 47    [Example]

Remote controller
case bottom

Remote
controller cord

Remote controller
case top

(1) Do not bundle the remote controller

cord, or wire the remote controller
cord in parallel, with the indoor unit
connection wire (to the outdoor
unit) and the power supply cord. It
may cause erroneous operation.

(2) When installing the remote con-

troller and cord near a source of
electromagnetic waves, separate the
remote controller from the source of
the electromagnetic waves and use
shielded cord.

(3) Do not touch the remote controller

PC board and PC board parts directly
with your hands.

Содержание 9363005011

Страница 1: ...igerant comes in contact with a flame it produces a toxic gas 5 Do not turn on the power until all installation work is complete Be careful not to scratch the air conditioner when handling it After installation explain correct operation to the customer using the operating manual Let the customer keep this installation installation manual because it is used when the air conditioner is serviced or m...

Страница 2: ...ts should not be obstructed the air should be able to blow all over the room 3 Do not install the unit where it will be exposed to direct sunlight 4 Install the unit where connection to the outdoor unit is easy 5 Install the unit where the drain pipe can be easily installed 6 Take servicing etc into consideration and leave the spaces shown in Fig 1 or 2 Also install the unit where the filter can b...

Страница 3: ...t Installation template For positioning the indoor unit Auxiliary pipe assembly For connecting the piping Indoor capillary tube This part is enclosed with the 30 000 and 36 000 BTU h versions BR sheet 65 x 130 x T5 This part is enclosed with the 30 000 and 36 000 BTU h versions Table 1 ELECTRICAL REQUIREMENT Table 2 Diameter 2 5 1 5 MAX MIN Connection cord mm2 45 000 36 000 BTU h class Small Large...

Страница 4: ...er B Left side Side cover A Right side Fig 5 Drilling position for Suspension bolt Ceiling Wall Template Drilling position for piping Fig 6 30 mm Suspension bolt pitch 1 600 mm 30 mm INDOOR UNIT TOP VIEW Dimensions Space Required for Installation For Half Concealed Installation Suspension bolt pitch should be as shown in Fig 6 Side cover B Right side 1 LOCATION OF CEILING SUSPENSION BOLTS 10 mm 15...

Страница 5: ...ou will set the suspension bolts Note that anchor bolts are M10 bolts to be obtained locally 2 Install the anchor bolts then temporarily attach spe cial nut B included and a locally procured M10 nut to each of the bolts See Fig 11 For Half Concealed Installation When installing the indoor unit in a semi concealed shape make sure to reinforce the insulation of the unit on all sides Drops of water m...

Страница 6: ...n three times When bending the pipe do not bend it as is The pipe will be collapsed In this case cut the heat insulating pipe with a sharp cutter as shown in Fig 17 and bend it after exposing the pipe After bending the pipe as you want be sure to put the heat insulating pipe back on the pipe and secure it with tape Fig 17 Pipe Heat insulating pipe Cutter Cut line Fig 16 Extend the pipe by unwindin...

Страница 7: ...Fig 21 in order to tighten the flare nut correctly Pipe Tightening torque Small pipe 9 53 mm dia 310 to 350 kgf cm 30 4 to 34 3 N m Large pipe 15 88 mm dia 750 to 800 kgf cm 73 5 to 78 4 N m Large pipe 19 05 mm dia 800 to 1 000 kgf cm 78 4 to 98 N m Table 4 Flare nut tightening torque Indoor unit side Outdoor unit side Indoor capillary tube Indoor capil lary tube Brazing all around Fig 23 BR sheet...

Страница 8: ...wiring 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using a round terminal fastener or pliers secure ly clamp a round terminal to each stripped wire end 4 Position the round terminal wire and replace and tighten the terminal screw using a screw dri ver Round terminal Terminal board Round terminal Screw with special washer Round terminal Wire Wire Install the drain pipe...

Страница 9: ...ting wires with different diameters causes the wires to heat up due to loose connections this method should not be used HOW TO FIX THE CONNECTION CORD After passing the connection cord through the insulation tube fasten it with the cord clamp Use VW 1 0 5 to 1 0 mm thick PVC tube as the insulation tube Fig 34 Insulation tube Insulation tube Cord clamp Fig 36 Cover A Control box 1 Before starting w...

Страница 10: ... Connect a maximum of 2 wires on a single terminal block If 3 or more wires are connected they could become loose and cause heating 2 Crossovers as in q should not be connected when connecting wires between the master unit and slave units and from slave unit to slave unit The system will not operate correctly Indoor unit Outdoor unit Master R Slave Slave Slave qwe qwe qwe qwe qwe S T N E BAD Fig 3...

Страница 11: ...d bottom with nippers file etc 2 Connect the remote controller cord to the remote controller terminal board specified in Fig 46 3 Clamp the remote controller cord sheath with the binder small as shown in Fig 46 4 Cut off the excess binder 2 When remote controller cord embedded 1 Embed the remote controller cord and box 2 Pass the remote controller cord through the hole at the remote controller cas...

Страница 12: ...t running When EE EE blinks at the current time display there is an error inside the air conditioner If the SET TIME button and SET TEMP DAY button are pressed simultaneously for more than three sec onds the self diagnosis check will start and the error contents will be displayed at the current time dis play Fig 49 When the operation lamp lights press the START STOP button and after operation lamp...

Страница 13: ...lamp TIMER lamp VERTICAL SWING lamp Error contents Model information abnormal permanent type Drain abnormal permanent type Indoor fan abnormal Room air temperature thermistor open circuited Room air temperature thermistor shortcircuited Piping thermistor open circuited Piping thermistor short circuited Serial communications abnormal Reverse phase wire connection abnormal Outdoor heat exchange ther...