En-1
1. SAFETY PRECAUTIONS
Be sure to read this manual carefully before installation.
The warnings and precautions indicated in this manual contain important information
pertaining to your safety. Be sure to observe them.
Hand this manual, together with the operating manual, to the customer. Request the cus-
tomer to keep them on hand for future use, such as for relocating or repairing the unit.
WARNING
This mark indicates procedures which, if improperly performed,
might lead to the death or serious injury of the user.
CAUTION
This mark indicates procedures which, if improperly performed,
might possibly result in personal harm to the user, or damage
to property.
WARNING
Installation of this product must be done by experienced service technicians or
professional installers only in accordance with this manual. Installation by nonprofessional
or improper installation of the product may cause serious accidents such as injury, water
leakage, electric shock, or
fi
re. If the product is installed in disregard of the instructions in
this manual, it will void the manufacturer’s warranty.
To avoid getting an electric shock, never touch the electrical components soon after the
power supply has been turned off. After turning off the power, always wait 10 minutes or
more before you touch the electrical components.
Do not turn on the power until all work has been completed. Turning on the power before
the work is completed can cause serious accidents such as electric shock or
fi
re.
If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant
comes in contact with a
fl
ame, it produces a toxic gas.
Installation must be performed in accordance with regulations, codes, or standards for
electrical wiring and equipment in each country, region, or the installation place.
Do not use this equipment with air or any other unspeci
fi
ed refrigerant in the refrigerant
lines. Excess pressure can cause a rupture.
During installation, make sure that the refrigerant pipe is attached
fi
rmly before you run
the compressor.
Do not operate the compressor under the condition of refrigerant piping not attached
properly with 3-way valve open. This may cause abnormal pressure in the refrigeration
cycle that leads to rupture and even injury.
When installing and relocating the air conditioner, do not mix gases other than the
speci
fi
ed refrigerant (R32) to enter the refrigerant cycle.
If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to an
abnormally high value and cause rupture, injury, etc.
WARNING
Do not remove the connection pipe while the compressor is in operation with 3-way
valve open.
This may cause abnormal pressure in the refrigeration cycle that leads to rupture and
even injury.
To connect the indoor unit and outdoor unit, use air conditioner piping and cables
available locally as standard parts. This manual describes proper connections using
such installation set.
Do not modify power cable, use extension cable or branch wiring. Improper use may
cause electric shock or
fi
re by poor connection, insuf
fi
cient insulation or over current.
Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation.
There is not extra refrigerant in the outdoor unit for air purging.
Use a vacuum pump for R32 or R410A exclusively.
Using the same vacuum pump for different refrigerants may damage the vacuum pump
or the unit.
Use a clean gauge manifold and charging hose for R32 or R410A exclusively.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition sources
(for example: open
fl
ames, an operating gas appliance or an operating electric heater.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
During the pump-down operation, make sure that the compressor is turned off before you
remove the refrigerant piping.
Do not remove the connection pipe while the compressor is in operation with 3-way
valve open.
This may cause abnormal pressure in the refrigeration cycle that leads to rupture and
even injury.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do
not play with the appliance.
CAUTION
For the air conditioner to work appropriately, install it as written in this manual.
The appliance shall not be installed in an unventilated space, if that space is smaller
than 1.61 m
2
.
This product must be installed by quali
fi
ed personnel with a capacity certi
fi
cation of
handling refrigerant
fl
uids. Refer to regulation and laws in use on installation place.
Install the product by following local codes and regulations in force at the place of
installation, and the instructions provided by the manufacturer.
This product is part of a set constituting an air conditioner. The product must not be
installed alone or be installed with non-authorized device by the manufacturer.
Always use a separate power supply line protected by a circuit breaker operating on all
wires with a distance between contact of 3 mm for this product.
To protect the persons, earth (ground) the product correctly, and use the power cable
combined with an Earth Leakage Circuit Breaker (ELCB).
This product is not explosion proof, and therefore should not be installed in explosive
atmosphere.
This product contains no user-serviceable parts. Always consult experienced service
technicians for repairing.
When installing pipes shorter than 3 m, sound of the outdoor unit will be transferred to the
indoor unit, which will cause large operating sound or some abnormal sound.
When moving or relocating the air conditioner, consult experienced service technicians
for disconnection and reinstallation of the product.
Do not touch the
fi
ns of the heat exchanger. Touching the heat exchanger
fi
ns could
result in damage to the
fi
ns or personal injury such as skin rupture.
INSTALLATION MANUAL
OUTDOOR UNIT
PART No. 9319205151-04
English
Contents
1. SAFETY PRECAUTIONS ................................................................................................ 1
2. ABOUT THE UNIT ........................................................................................................... 3
2.1. Special tools for R32 ............................................................................................ 3
2.2. Accessories .......................................................................................................... 4
3. GENERAL SPECIFICATION ........................................................................................... 4
3.1. Selecting circuit breaker and wiring ...................................................................... 4
3.2. Selecting the pipe material ................................................................................... 4
3.3. Protection of pipes ................................................................................................ 4
3.4. Refrigerant pipe size and allowable piping length ................................................ 4
4. INSTALLATION WORK ................................................................................................... 5
4.1. Selecting an installation location .......................................................................... 5
4.2. Drain installation ................................................................................................... 5
4.3. Installation dimensions ......................................................................................... 5
4.4. Installation ............................................................................................................ 6
5. OUTDOOR UNIT INSTALLATION ................................................................................... 7
5.1. Switch cover remove ............................................................................................ 7
5.2. Notes for electrical wiring ..................................................................................... 7
5.3. Wiring method ...................................................................................................... 8
5.4. Flare connection (pipe connection) ...................................................................... 8
5.5. Sealing test ........................................................................................................... 9
5.6. Vacuum process ................................................................................................... 9
5.7. Installing insulation ............................................................................................. 10
6. TEST RUN ..................................................................................................................... 10
7. INFORMATION .............................................................................................................. 10
[Original instructions]
9319205151-04_IM.indb 1
9319205151-04_IM.indb 1
1/12/2017 11:49:07 AM
1/12/2017 11:49:07 AM