background image

En-1

1. SAFETY PRECAUTIONS

Be sure to read this manual carefully before installation.

The warnings and precautions indicated in this manual contain important information 

pertaining to your safety. Be sure to observe them.

Hand this manual, together with the operating manual, to the customer. Request the cus-

tomer to keep them on hand for future use, such as for relocating or repairing the unit.

 

WARNING

This mark indicates procedures which, if improperly performed, 
might lead to the death or serious injury of the user.

 CAUTION

This mark indicates procedures which, if improperly performed, 
might possibly result in personal harm to the user, or damage 
to property.

 WARNING

Installation of this product must be done by experienced service technicians or 
professional installers only in accordance with this manual. Installation by nonprofessional 
or improper installation of the product may cause serious accidents such as injury, water 
leakage, electric shock, or 

fi

 re. If the product is installed in disregard of the instructions in 

this manual, it will void the manufacturer’s warranty.

To avoid getting an electric shock, never touch the electrical components soon after the 
power supply has been turned off. After turning off the power, always wait 10 minutes or 
more before you touch the electrical components.

Do not turn on the power until all work has been completed. Turning on the power before 
the work is completed can cause serious accidents such as electric shock or 

fi

 re.

If refrigerant leaks while work is being carried out, ventilate the area. If the refrigerant 
comes in contact with a 

fl

 ame, it produces a toxic gas.

Installation must be performed in accordance with regulations, codes, or standards for 
electrical wiring and equipment in each country, region, or the installation place.

Do not use this equipment with air or any other unspeci

fi

 ed refrigerant in the refrigerant 

lines. Excess pressure can cause a rupture.

During installation, make sure that the refrigerant pipe is attached 

fi

 rmly before you run 

the compressor. 
Do not operate the compressor under the condition of refrigerant piping not attached 
properly with 3-way valve open. This may cause abnormal pressure in the refrigeration 
cycle that leads to rupture and even injury.

When installing and relocating the air conditioner, do not mix gases other than the 
speci

fi

 ed refrigerant (R32) to enter the refrigerant cycle. 

If air or other gas enters the refrigerant cycle, the pressure inside the cycle will rise to an 
abnormally high value and cause rupture, injury, etc.

 WARNING

Do not remove the connection pipe while the compressor is in operation with 3-way 
valve open. 
This may cause abnormal pressure in the refrigeration cycle that leads to rupture and 
even injury.

To connect the indoor unit and outdoor unit, use air conditioner piping and cables 
available locally as standard parts. This manual describes proper connections using 
such installation set.

Do not modify power cable, use extension cable or branch wiring. Improper use may 
cause electric shock or 

fi

 re by poor connection, insuf

fi

 cient insulation or over current.

Do not purge the air with refrigerants but use a vacuum pump to vacuum the installation.

There is not extra refrigerant in the outdoor unit for air purging.

Use a vacuum pump for R32 or R410A exclusively.

Using the same vacuum pump for different refrigerants may damage the vacuum pump 
or the unit.

Use a clean gauge manifold and charging hose for R32 or R410A exclusively.

Do not use means to accelerate the defrosting process or to clean, other than those 
recommended by the manufacturer.

The appliance shall be stored in a room without continuously operating ignition sources 
(for example: open 

fl

 ames, an operating gas appliance or an operating electric heater.

Do not pierce or burn.

Be aware that refrigerants may not contain an odour.

During the pump-down operation, make sure that the compressor is turned off before you 
remove the refrigerant piping. 
Do not remove the connection pipe while the compressor is in operation with 3-way 
valve open. 
This may cause abnormal pressure in the refrigeration cycle that leads to rupture and 
even injury.

This appliance is not intended for use by persons (including children) with reduced 
physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised to ensure that they do 
not play with the appliance.

 CAUTION

For the air conditioner to work appropriately, install it as written in this manual.

The appliance shall not be installed in an unventilated space, if that space is smaller 
than 1.61 m

2

.

This product must be installed by quali

fi

 ed personnel with a capacity certi

fi

 cation  of 

handling refrigerant 

fl

 uids. Refer to regulation and laws in use on installation place.

Install the product by following local codes and regulations in force at the place of 
installation, and the instructions provided by the manufacturer.
This product is part of a set constituting an air conditioner. The product must not be 
installed alone or be installed with non-authorized device by the manufacturer.
Always use a separate power supply line protected by a circuit breaker operating on all 
wires with a distance between contact of 3 mm for this product.
To protect the persons, earth (ground) the product correctly, and use the power cable 
combined with an Earth Leakage Circuit Breaker (ELCB).
This product is not explosion proof, and therefore should not be installed in explosive 
atmosphere.
This product contains no user-serviceable parts. Always consult experienced service 
technicians for repairing.
When installing pipes shorter than 3 m, sound of the outdoor unit will be transferred to the 
indoor unit, which will cause large operating sound or some abnormal sound.
When moving or relocating the air conditioner, consult experienced service technicians 
for disconnection and reinstallation of the product.
Do not touch the 

fi

 ns of the heat exchanger. Touching the heat exchanger 

fi

 ns  could 

result in damage to the 

fi

 ns or personal injury such as skin rupture.

INSTALLATION MANUAL

OUTDOOR UNIT 

PART No. 9319205151-04 

English

Contents

1. SAFETY PRECAUTIONS ................................................................................................ 1

2. ABOUT THE UNIT ........................................................................................................... 3

2.1. Special tools for R32 ............................................................................................ 3
2.2. Accessories .......................................................................................................... 4

3. GENERAL SPECIFICATION ........................................................................................... 4

3.1. Selecting circuit breaker and wiring ...................................................................... 4
3.2. Selecting the pipe material ................................................................................... 4
3.3. Protection of pipes ................................................................................................ 4
3.4. Refrigerant pipe size and allowable piping length ................................................ 4

4. INSTALLATION WORK ................................................................................................... 5

4.1. Selecting an installation location .......................................................................... 5
4.2. Drain installation ................................................................................................... 5
4.3. Installation dimensions ......................................................................................... 5
4.4. Installation ............................................................................................................ 6

5. OUTDOOR UNIT INSTALLATION ................................................................................... 7

5.1. Switch cover remove ............................................................................................ 7
5.2. Notes for electrical wiring ..................................................................................... 7
5.3. Wiring method ...................................................................................................... 8
5.4. Flare connection (pipe connection) ...................................................................... 8
5.5. Sealing test ........................................................................................................... 9
5.6. Vacuum process ................................................................................................... 9
5.7. Installing insulation ............................................................................................. 10

6. TEST RUN ..................................................................................................................... 10

7. INFORMATION .............................................................................................................. 10

[Original instructions]

9319205151-04_IM.indb   1

9319205151-04_IM.indb   1

1/12/2017   11:49:07 AM

1/12/2017   11:49:07 AM

Содержание 9319205151-04

Страница 1: ... autorizado MANUALE D INSTALLAZIONE UNITÀ ESTERNA A uso esclusivo del personale tecnico autorizzato ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ ΕΞΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό MANUAL DE INSTALAÇÃO UNIDADE EXTERIOR Semente para pessoal do serviço técnico autorizado РУКОВОДСТВО ПО УСТАНОВКЕ ВНЕШНИЙ МОДУЛЬ Только для авторизованного обслуживающего персонала KURULUM KILAVUZU DIŞ ÜNİTE Yalnızca...

Страница 2: ...ay damage the vacuum pump or the unit Use a clean gauge manifold and charging hose for R32 or R410A exclusively Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do...

Страница 3: ...rant R410A R22 models However pay careful attention to the following points WARNING Since the working pressure is 1 6 times higher than that of refrigerant R22 models some of the piping and installation and service tools are special See 2 1 Special tools for R32 Especially when replacing a refrigerant R22 model with a new refrigerant R32 model always replace the conventional piping and flare nuts ...

Страница 4: ...ylinders conform to the appropriate standards d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that refrigerant can be removed from various parts of the system f Make sure that cylinder is situated on the scales before recovery takes place g Start the recovery machine and operate in accordance with manufacturer s instructions h Do not overfill cylinders N...

Страница 5: ...ype60245 IEC57 3 wire Ground 1 Φ 230 V 1 Selected sample Select the correct cable type and size according to the country or region s regulations Max wire length Set a length so that the voltage drop is less than 2 Increase the wire diameter when the wire length is long Breaker capacity A Earth leakage breaker mA 09 type 16 30 12 type 20 Selected sample Select the correct cable type and size accord...

Страница 6: ... outlet ducts Install the outdoor unit in a location that is away from exhaust or the vent ports that discharge vapor soot dust or debris Install the indoor unit outdoor unit power supply cable connection cable and remote controller cable at least 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more...

Страница 7: ...tated above the condition will be the same as when there is no obstacle Height above the floor level should be 50 mm or more When installing the outdoor unit be sure to open the front and left side to obtain better operation efficiency 4 4 Installation Unit mm 570 340 Install 4 anchor bolts at the locations indicated with arrows in the above figure To reduce vibration do not install the unit direc...

Страница 8: ...if lightning strikes Improper grounding work can cause electric shocks Securely install the electrical box cover on the unit An improperly installed service panel can cause serious accidents such as electric shock or fire through exposure to dust or water Do not connect the AC power supply to the transmission line terminal board Improper wiring can damage the entire system CAUTION The primary powe...

Страница 9: ... damaged Do not remove the flare nut from the indoor unit pipe until immediately before connecting the connection pipe 2 Centering the pipe against port on the outdoor unit turn the flare nut with your hand To prevent gas leakage coat the flare surface with alkylbenzene oil HAB Do not use mineral oil 3 Tighten the flare nut of the connection pipe at the outdoor unit valve connector Flare nut Conne...

Страница 10: ...ease the nitrogen gas slowly 5 6 Vacuum process CAUTION Perform a refrigerant leakage test air tightness test to check for leaks using nitrogen gas while all valves in the outdoor unit are closed Use the test pressure indicated on the nameplate Be sure to evacuate the refrigerant system using a vacuum pump The refrigerant pressure may sometimes not rise when a closed valve is opened after the syst...

Страница 11: ...label Item Detail MODEL Model name Electric characteristics Rated voltage phase and frequency COOLING CAPACITY Cooling capacity under cooling condition CURRENT Electric current during cooling operation under cooling condition INPUT POWER Input during cooling operation under cooling condition ENERGY EFFICIENCY RATIO Ratio of output cooling energy to electrical input energy HEATING CAPACITY Heating ...

Отзывы: