Appendix A
Message Meaning and Handling
A-23
SCF error
[Explanation] Internal error happened during kernel migration.
[Remedy] Please contact customer service.
A.2
Command Messages
A.2.1
addboard
XSB#XX-X will be assigned to DomainID X. Continue? [y|n]:
[Explanation] Confirming whether DR operation is going to be executed or not.
Input "y" to execute it and "n" to stop it.
XSB#XX-Xwill be configured into DomainID X. Continue? [y|n]:
[Explanation] Confirming whether DR operation is going to be executed or not.
Input "y" to execute it and "n" to stop it.
DR operation canceled by operator.
[Explanation] DR operation canceled by operator.
Domain (DomainID X) is not currently running.
[Explanation] Destination domain #0 was not active when "
-c configure
" was
specified.
[Remedy] Execute it by specifying "
-c assign
".
XSB#XX-X is already assigned to another domain.
[Explanation] The specified system board (XSB#XX-X) has already been assigned
to another domain.
[Remedy] XSB has already been assigned to another domain. Confirm the XSB by
showboards
(8).
XSB#XX-X is not installed.
[Explanation] System board (XSB#XX-X) is not installed.
[Remedy] Specify the wrong XSB. Confirm the XSB by
showboards
(8).
Содержание SPARC Enterprise M4000
Страница 1: ...Dynamic Reconfiguration DR User s Guide SPARC Enterprise M4000 M5000 M8000 M9000 Servers English ...
Страница 2: ......
Страница 6: ......
Страница 23: ...Preface xxi Reader s Comment Form ...
Страница 90: ...3 28 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 116: ...4 26 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 152: ...A 36 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 158: ...Glossary 4 SPARC Enterprise Mx000 Servers Dynamic Reconfiguration User s Guide September 2007 ...
Страница 161: ......