background image

PRIMERGY

PRIMERGY Econel 200
Server System   

Operating Manual

Gottfried Staubach/Xenia Fierley
Fujitsu Siemens Computers GmbH München
81730 München
e-mail: email: [email protected]
Tel.: (0 5251) 8-15244 / o89-61001-157
Fax: (++49) 700 / 372 00000
A26361-K970-Z102-2-7619
Sprachen:  En          

Edition September 2005

Содержание PRIMERGY Econel 200

Страница 1: ...ing Manual Gottfried Staubach Xenia Fierley Fujitsu Siemens Computers GmbH M nchen 81730 M nchen e mail email manuals fujitsu siemens com Tel 05251 8 15244 o89 61001 157 Fax 49 700 372 00000 A26361 K9...

Страница 2: ...artment Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quali...

Страница 3: ...ction Installation Steps Overview Important Notes Hardware Installation Preparation for Use and Operation Property and Data Protection Problem Solutions and Tips Abbreviations Related publications and...

Страница 4: ......

Страница 5: ...Server to the Line Voltage 26 4 4 Hints Connecting Disconnecting Cables 28 5 Preparation for Use and Operation 29 5 1 Operating and Indicator Elements 29 5 1 1 The Front 29 5 1 2 The Rear 31 5 2 Switc...

Страница 6: ...splayed on the Monitor 43 7 7 Floppy Disk Cannot be Read or Written onto 44 7 8 Time and or Date are Incorrect 44 7 9 RAID Critical Status Condition during Boot 45 7 10 System Fails to Boot 46 7 11 Dr...

Страница 7: ...anuals are available in PDF format on the ServerBooks CD The ServerBooks CD is part of the ServerView Suite delivered with each server system The PDF files for the manuals can also be downloaded free...

Страница 8: ...etup Utility manual PDF file available on the ServerBooks CD PRIMERGY Econel 200 Server System Options Guide PDF file available on the ServerBooks CD I In the Options Guide the server extension and mo...

Страница 9: ...n the ServerBooks CD Integrated Mirroring User s Guide PDF file available on the ServerBooks CD Ultra320 SCSI Host Adapters User s Guide PDF file available on the ServerBooks CD Further sources of inf...

Страница 10: ...cable The SATA hard disk drives are controlled by an onboard SATA RAID controller up to two drives or by an optional PCI SATA RAID controller up to four drives Basic configuration with SCSI hard disk...

Страница 11: ...ty for the internal disk configuration RAID levels 1 1E I For IME configuration the controller has its own utility For further infor mation see the Integrated Mirroring User s Guide on the ServerBooks...

Страница 12: ...ns with timely notification before a failure Watchdog timer for operating system monitoring and application monitoring Further information on the ServerView server management is provided in the associ...

Страница 13: ...e performed in the order shown V CAUTION pay particular attention to text marked with this symbol Failure to observe this warning may endanger your life damage the server or lead to loss of data I sup...

Страница 14: ...cs IEC 60950 EN 60950 UL 60950 3rd Ed CAN CSA C22 2 No 60950 3rd Ed Electromagnetic Compatibility FCC class A VCCI class A AS NZS 3548 class A CNS 13438 Emitted interference EN 55022 class A Harmonic...

Страница 15: ...nvironment class 3K2 Environment class 2K2 EN 60721 IEC 721 section 3 3 EN 60721 IEC 721 section 3 2 Temperature Operation 3K2 Transport 2K2 10 C 35 C 25 C 60 C Relative humidity 10 85 Sound power lev...

Страница 16: ......

Страница 17: ...able possibly print of the PDF files Set up the server see section Unpacking and Setting up the Server on page 24 Cable the server Please also refer to the section Connecting Devices to the Server on...

Страница 18: ...hout ServerStart see section Configuration with ServerStart on page 36 or section Configuration without ServerStart on page 36 respectively I To find out how to operate ServerStart and for further inf...

Страница 19: ...u can set up the device contact your sales outlet or our customer service team V CAUTION The actions described in these instructions should only be performed by technical specialists Equipment repairs...

Страница 20: ...nstallation and operation V CAUTION The server automatically sets itself to a voltage in the range of 100 V to 240 V Make sure that your local voltage is within this range This device has a specially...

Страница 21: ...elets or paper clips fall into or liquids spill into the device risk of electric shock or short circuit In emergencies e g damaged casing controls or cables penetration of liquids or foreign matter sw...

Страница 22: ...n The battery may only be replaced with an identical battery or with a type recommended by the manufacturer see the technical manual for the system board under Related publications on page 53 Do not t...

Страница 23: ...e the cover of the drive damage to the device and be thrown out of the device danger of injury particularly on uncovered body parts such as the face or neck I You protect the CD DVD drive and prevent...

Страница 24: ...g ESDs You must always discharge yourself of static charges e g by touching a grounded object before working Use a grounding cable designed for this purpose to connect yourself to the system unit as y...

Страница 25: ...rules and meets all requirements of the Canadian Interference Causing Equipment Standard ICES 003 for digital apparatus These limits are designed to provide reasonable protection against harmful inter...

Страница 26: ...achment of connecting cables and equipment other than those specified by Fujitsu Siemens Computers The correction of interferences caused by such unauthorized modification substitution or attachment w...

Страница 27: ...ot have to be switched on permanently should be switched off until they are needed as well as during long breaks and after completion of work Notes on packaging Please do not throw away the packaging...

Страница 28: ...nd disposal For details on take back and reuse of devices and consumables within Europe contact your Fujitsu Siemens Computers branch office subsidiary or our recycling centre in Paderborn Fujitsu Sie...

Страница 29: ...ons see section Technical Data on page 7 Protect it from dust moisture and heat In order to avoid the formation of condensation inside or on the outside of the hard disk drives the server must be accl...

Страница 30: ...te Transport the server to the desired site Unpack all the individual parts Check the contents of the package for visible transport damage Check whether the delivery agrees with the details in the del...

Страница 31: ...ica tions on page 53 The standard ports figure 2 are marked with symbols and some are color coded Figure 2 Standard ports I Some of the devices that you connect require special driver software see the...

Страница 32: ...ally switched on or off together with the server V CAUTION You may only connect the monitor to the server s AC outlet if the monitor s current consumption does not exceed 2 A The rated current for the...

Страница 33: ...ing the Server to the Line Voltage Figure 3 Connecting the server to the line voltage Connect the insulated connector of the power cable to the power supply unit of the server 1 and the power plug to...

Страница 34: ...off all power and equipment switches Unplug all power plugs of grounded power sockets Plug all cables into the server and peripherals Secure the data transmission cable connections e g nut retention...

Страница 35: ...tant Notes on page 13 5 1 Operating and Indicator Elements 5 1 1 The Front Figure 4 The front operating and indicator elements 1 ON OFF button 4 CD DVD eject button 2 Power on indicator 5 CD DVD acces...

Страница 36: ...ll switch OFF the system standby For more information see Other ON OFF possibilities on page 33 I The ON OFF button does not disconnect the server from the mains voltage To completely disconnect it fr...

Страница 37: ...ain switch LED indicators on the LAN port Figure 6 LED indicators on the LAN port 1 LAN connection indicator green Lights when a LAN connection is established Flashes when data is being received or se...

Страница 38: ...in switch if available is in the ON position see figure 5 on page 31 First system installation Press the ON OFF button position 1 in figure 4 on page 29 The power on LED lights green position 2 figure...

Страница 39: ...dby mode The power on indicator lights orange Other ON OFF possibilities In addition to the ON OFF button the server can be switched ON and OFF in the following ways Specified switch On time switch OF...

Страница 40: ...oller FastTrak S150 TX4 This controller is optional Configuring is either performed via the BIOS config uration utility calling CTRL F during BIOS POST or with the ServerStart CD using PAM Promise Arr...

Страница 41: ...ServerStart or with ServerStart recommended Configuring the SCSI RAID controller is either performed via the BIOS configu ration utility calling CTRL C during BIOS POST or with the ServerStart CD usi...

Страница 42: ...figuration via PAM Promise Array Manager To find out how to operate ServerStart and for further information refer to the corresponding ServerStart manual see Related publications on page 53 If you use...

Страница 43: ...s job to a service technician Do not use any cleaning agents that contain abrasives or may corrode plastic Ensure that no liquid enters the system Ensure that the ventilation areas of the server and t...

Страница 44: ......

Страница 45: ...which enables the ServerView program to detect any removal of the left cover or housing cover An alert message is displayed To prevent the server from being removed from its location it can be secure...

Страница 46: ...our data from unauthorized access For example you can assign passwords prevent diskette writing or BIOS flashing By combining these options in a meaningful way you can achieve optimum protection for y...

Страница 47: ...s that led to the fault Note also any error message which may have been displayed Switch the server OFF Contact our Service organization 7 1 Power on Indicator Remains Dark The power on indicator rema...

Страница 48: ...r the appropriate password Brightness control is set too dark Adjust the brightness control to increase the brightness For detailed infor mation please refer to the operating manual supplied with your...

Страница 49: ...ngly 7 5 No Monitor Display or Display Drifts The wrong horizontal frequency and or resolution has been selected for the monitor or for the application program Find out which horizontal frequency your...

Страница 50: ...ck whether the mechanical write protection of the floppy disk is enabled In BIOS Setup check the floppy disk drive setting in the Main menu It must not be Disabled In BIOS Setup check the Diskette Wri...

Страница 51: ...or error cause and how to eliminate the error in the FastTrak S150 TX4 User Manual chapter Troubleshooting Tips see Related publications on page 53 Further information is also provided in the manual o...

Страница 52: ...ves with the RAID controller utility Further information is provided in the manual on the RAID controller 7 12 Added Drive Defective This error message can occur with the SCSI or with the SATA server...

Страница 53: ...s Institute ASR R Automatic Server Reconfiguration and Restart BIOS Basic Input Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk CD ROM Compact Disk Read Only Memor...

Страница 54: ...terface ECC Error Checking and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read Only Memory EMC ElectroMagnetic Compatibility EMP Emergency Management Port EPP...

Страница 55: ...ce HDD Hard Disk Drive HSC Hot Swap Controller I C Inter Integrated Circuit I O Input Output ICES Interference Causing Equipment Standard Canada ICM Intelligent Chassis Management ID Identification ID...

Страница 56: ...t Number LVD Low Voltage Differential SCSI MMF Multi Mode Fibre MRL Manual Retention Latch NMI Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS Operating System PAM Promise Array Mana...

Страница 57: ...mote Service Board RTC Real Time Clock RTDS Remote Test und Diagnose System SAF TE SCSI Accessed Fault Tolerance Enclosures SATA Serial ATA Advanced Technology Attachment SBE Single Bit Error SCA Sing...

Страница 58: ...Event Log S M A R T Self Monitoring Analysis and Reporting Technology SMI System Management Interrupt SSU System Setup Utility SVGA Super Video Graphics Adapter USB Universal Serial Bus VGA Video Grap...

Страница 59: ...view page showing the online documen tation available on the Internet can be found via the URL http manuals fujitsu siemens com choose industry standard servers 1 Safety 2 Ergonomics 3 Warranty 4 Syst...

Страница 60: ...us S150 TX4 and TX4000 User Manual 13 LSI SATA Software RAID User Manual 14 Global Array Manager Client Software User s Guide 15 Global Array Manager Server Software User s Guide 16 Integrated Mirrori...

Страница 61: ...cables 28 disposal of devices 22 drive array critical error 45 dead 46 defective 46 error 45 indicators 30 drive active indicator 29 30 DVD drive indicator 29 30 E ECC 5 electrical data 7 electromagne...

Страница 62: ...tion additional 3 Intergrated Mirroring Enhanced IME 5 L light emitting diode LED 17 lithium battery 16 low voltage directive 8 19 M mains voltage connecting the server 26 meaning of the symbols 7 mod...

Страница 63: ...dimensions 8 electrical data 7 environmental conditions 9 indicators 29 keyboard port 25 LAN port 25 monitor port 25 mouse port 25 noise level 9 ON OFF button 29 30 operation 29 operator panel 29 port...

Страница 64: ...6361 K970 Z102 2 7619 Index T take back of devices 22 target group 1 technical data 7 time wrong 44 transport damage 24 troubleshooting server 41 U unpacking server 24 V ventilation clearance 8 W weig...

Страница 65: ...System A26361 K970 Z102 2 7619 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals fujitsu siemens...

Страница 66: ......

Страница 67: ...System A26361 K970 Z102 2 7619 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 M nchen Germany Fax 49 700 372 00000 email manuals fujitsu siemens...

Страница 68: ......

Страница 69: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochte...

Отзывы: