26
A26361-K970-Z102-2-7619
Connecting the Server to the Line Voltage
Hardware Installation
4.2.1
Connecting the Monitor
Ê
Connect the monitor data cable to the monitor port of the server (5).
Ê
Connect the power cable of the monitor to the server’s AC outlet (if available)
or to a grounded mains outlet of the in-house mains.
I
It is recommended to use the AC outlet of the server (if available). Thus,
the monitor is automatically switched on or off together with the server.
V
CAUTION!
You may only connect the monitor to the server’s AC outlet if the monitor’s
current consumption does not exceed 2 A. The rated current for the
monitor can be found on the technical data label on the monitor or in the
operating manual for the monitor.
4.3
Connecting the Server to the Line Voltage
The server is equipped with a fixed power supply unit.
V
CAUTION!
The server automatically adjusts to a mains voltage between
100 - 240 V. The server may be placed in operation only if the mains
voltage range set on the server corresponds to the local mains voltage.