MYRICA P42-1AH / P42-2H / P50-2H
34 - English
A26361-K1064-Z120-1-M119, edition 2
MYRICA P42-1AH
MYRICA P42-2H
MYRICA P50-2H
DVI:
TMDS ( DVI-D)
Power supply (AC):
100 - 240 V (50/60 Hz)
1,8 A / 240 V
4,4 A / 100 V
100 - 240 V (50/60 Hz)
2,0 A / 240 V
4,5 A / 100 V
100 - 240 V (50/60 Hz)
5,0 A / 240 V
2,0 A / 100 V
Power consumption:
Typical: 380 W
Standby < 5 W
Typical: 420 W
Standby < 5 W
Typical: 500 W
Standby < 3 W
Dimensions:
Width x Depth x
Height:
1037 x 94 x 635 mm
(without foot)
1037 x 240 x 703 mm
(with foot)
1037 x 94 x 635 mm
(without foot)
1037 x 240 x 703 mm
(with foot)
1208 x 94 x 723 mm
(without foot)
1037 x 360 x 775 mm
(with foot)
Weight:
approx. 41 kg
packed approx. 48 kg
approx. 41 kg
packed approx. 48 kg
approx. 54 kg
packed approx. 62 kg
Audio:
Audio input:
DVI / PC, Video 1,
S-Video,
Component1/2,
(SCART 1, SCART 2)
RCA connection (L, R) 0.5 Vms
Audio output:
0.5 Vms at 1 kHz
Loudspeaker output:
approx. 2 x 8 W (8 Ohm)
RS-232: For
Service
only
Standard certificate:
Security: TÜV-GS
,CE
EMC:
TV mode: EN55020 class B, EN 55013, EN 61000-3-2/-3 (see CE)
PC mode: EN55022 class B, EN 55024, EN 61000-3-2/-3 (see CE)
Environment:
Condensation must be avoided.
Temperature:
Operating: +15 ° to +35 ° C
Storage: -15 ° to + 60 ° C
Change: 1.5 ° C/minute maximum
Humidity:
Operation: 20 - 85 % without condensation
Storage: 20 - 85 % without condensation
Pressure:
Operation : 800 - 1,114 hPa (height: 0 - 2000 m)
Storage : 600 - 1,114 hPa (height: 0 - 4500 m)
Accessories:
Manual, remote control, battery
Power supply cable: 1.8 m
Foot with mounting screws