background image

 

 

QRG-04 

Quick  Reference  Guide 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Objective Lens 

Cotton swab 

Fiber 

Cleaning before Splice Operation 

Clamp chips 

 

After installation, execute [Stabilized Electrodes] followed by an [Arc Calibration].

 

V-grooves

 

 

When the lens is dirty, clean it with a thin 
cotton swab moistened with alcohol. 

 

Remove the electrodes when cleaning the 
lenses.   

Cleaning Cautions

 

 

Electrode Replacement 

 

When “Replace electrodes” message appears, or when the tip is damaged, replace electrodes. 

 

Execute [Replace Electrodes]

 

 

Exchange to new electrode. 

 

Install new electrodes 

Loosen screws 

Remove the old electrodes 

Tighten screws 

Screws 

V-groove Clamps

 

Tools 

Optical fiber cleaver 

Clean rubber pads. 

Clean rubber anvil.   

Clean cleaving blade. 

 

Ribbon fiber stripper 

Clean stripping blade 

 

Do not allow contact onto the electrode tips.   

 

Use only 99% or better purity of alcohol 

 

Use new lint-free cotton swab every time you clean.

 

 

Clean bottom of V-groove with a thin 
cotton swab with alcohol. 

 

Remove excess alcohol from V-grooves 
with a clean dry swab. 

 

Use a cleaved fiber end-face to dislodge. 

《Replace the electrode after selecting [Electrode Replacement] in the maintenance menu.》 

Содержание QRG-04

Страница 1: ...Stripper Mass Fusion Splicer Fiber Holder Splice Mode Select SM AUTO to splice standard SM fibers ITU T G 652 ON OFF Power ON OFF HEAT UP DOWN Move cursor Change value Open the Classic Menu with key in READY screen Heater ON OFF RESET SET Power LED Power ON green LED turns on Battery Charge orange LED blinked HEAT LED Heater ON orange LED blinked Sheet Key Operation Power LED HEAT LED Tool for Spl...

Страница 2: ...roper tension to the fiber during transition to the tube heater to avoid bending of the fiber There are two slots one for 40mm and one for 60mm Use the appropriate slot according to sleeve size Keep applying tension to the fiber until the heater clamps hold it Pull Keep pinching here Marking Clean fiber coating Place protection sleeve Place the fiber in the fiber holder Strip fiber Clean fiber Spl...

Страница 3: ... Replace Electrodes Exchange to new electrode Install new electrodes Loosen screws Remove the old electrodes Tighten screws Screws V groove Clamps Tools Optical fiber cleaver Clean rubber pads Clean rubber anvil Clean cleaving blade Ribbon fiber stripper Clean stripping blade Do not allow contact onto the electrode tips Use only 99 or better purity of alcohol Use new lint free cotton swab every ti...

Страница 4: ...er cleaver Check the cleave length Execute Dust Check Clean the lens when dust or dirt exists Too Dusty Fiber Dust or dirt is on the fiber surface Dust or dirt is on the objective lens Cleaning Arc time is too short or OFF Completely prepare the fiber again strip clean and cleave Execute the Dust Check Clean the lens if dust or dirt exists Increase the Cleaning Arc time in small increments ZL ZR M...