QRG-04
Quick Reference Guide
Setup & Preparation before Splicing
Plug AC adaptor into the DC adaptor.
*No need when using battery pack.
Turn splicer ON.
Confirm Heater Mode
Check Wireless Communication
Clean before splicing
Setup & Preparation complete
Confirm Splice Mode
LED
Select the adequate heater mode according to the sleeve.
The [READY] screen shows the current heater mode.
When using a protection sleeve which is not made by
Fujikura, please set parameters based on the specific
sleeve.
Heater Mode
LED Indication
Optical Fiber
Cleaver
Protection sleeve
Ribbon Fiber
Stripper
Mass Fusion
Splicer
Fiber Holder
Splice Mode
Select ”
SM AUTO
” to splice standard SM fibers (ITU-T
G.652).
ON/OFF
・
Power ON/OFF
HEAT
UP/DOWN
・
Move cursor
・
Change value
・
Open the “Classic Menu” with
▼
key in [READY] screen.
・
Heater ON/OFF
RESET
SET
・
Power LED
Power ON
:
green
LED turns on.
Battery Charge:
orange
LED blinked
・
HEAT LED
Heater ON:
orange
LED blinked
Sheet Key Operation
Power LED
HEAT LED
Tool for Splicing Operation
Consumables for
cleaning
Cotton
Cotton swab
Alcohol
Turning ON
Press key until
green
LED turns on.
Turning OFF
Press key until
red
LED
turns on.
Turning ON
Press key until
green
LED turns on, then
release.
Turning OFF
Press key until
red
LED turns on,
then release.
・
Execute Splice
・
Hold down to
navigate to next
page in the menu
・
Stop and back to
Ready state