- 30 -
1.
Set the receiver to MAXIMUM/PEAK mode:
2.
Press the Depth key once:
The display will then say “Pull Up”.
3.
Without pulling up, press the Depth key again:
The receiver should now be in Transverse Depth Measurement
mode.
4.
Move the receiver along one of the perpendicular sides to
the pipeline, as shown in the diagram to the left.
5.
Mark the point where the marker and bar graph align. The
buzzer should also be audible.
6.
Repeat the process on the other side of the pipeline.
The total distance equals the depth. This method is suitable for
depths of 0.5-2.0 meters.
To return to the MAX/PEAK mode, press the Sensitivity
Adjustment key.
OPERATION OF RECEIVER
5-2-5 Transverse Depth Measurement
27kHz S21
③
Transvers depth measurement screen
LED Lighting
036
100
Marker Bar graph
051
②
Press 1 time
①
Press 1 more time
* Right on the
buried pipe
LED Lighting
LED Lighting
036
L
L
Depth of buried pipe = L x 2