Installation and wiring 

 

 

•  Before starting installation and wiring, turn OFF the power and wait at least five minutes for inverters 

with a capacity of 22 kW or below, or at least ten minutes for inverters with a capacity of 30 kW or 
above. Make sure that the LED monitor and charging lamp are turned OFF. Further, make sure, 
using a multimeter or a similar instrument, that the DC link bus voltage between the terminals P(+) 
and N(-) has dropped to the safe level (+25 VDC or below). 

•  Qualified electricians should carry out wiring. 
 

Otherwise, an electric shock could occur.

 

 

 

•  Do not use the product that is damaged or lacking parts. 

  Doing so could cause a fire, an accident, or injuries.

 

•  Prevent lint, paper fibers, sawdust, dust, metallic chips, or other foreign materials from getting into 

the inverter and the communications card. 

  Otherwise, a fire or an accident might result.

 

•  Incorrect handling in installation/removal jobs could cause a failure. 
 

A failure might result.

 

•  Noise may be emitted from the inverter, motor and wires. Implement appropriate measure to prevent 

the nearby sensors and devices from malfunctioning due to such noise. 

 

Otherwise, an accident could occur.

 

 

Operation 

 

 

•  Be sure to install the front cover before turning the inverter's power ON. Do not remove the cover 

when the inverter power is ON. 

 

Otherwise, an electric shock could occur.

 

•  Do not operate switches with wet hands. 
 

Doing so could cause an electric shock.

   

•  If you configure the function codes wrongly or without completely understanding FRENIC-MEGA 

Instruction Manual and the FRENIC-MEGA User's Manual, the motor may rotate with a torque or at a 
speed not permitted for the machine. Confirm and adjust the setting of the function codes before 
running the inverter.

 

 

Otherwise, an accident could occur.

 

 

 

Maintenance and inspection, and parts replacement 

 

 

•  Before proceeding to the maintenance/inspection jobs, turn OFF the power and wait at least five 

minutes for inverters with a capacity of 22 kW or below, or at least ten minutes for inverters with a 
capacity of 30 kW or above. Make sure that the LED monitor and charging lamp are turned OFF. 
Further, make sure, using a multimeter or a similar instrument, that the DC link bus voltage between 
the terminals P(+) and N(-) has dropped to the safe level (+25 VDC or below). 

 

Otherwise, an electric shock could occur.

 

•  Maintenance, inspection, and parts replacement should be made only by qualified persons. 
•  Take off the watch, rings and other metallic objects before starting work. 
•  Use insulated tools. 

  Otherwise, an electric shock or injuries could occur.

 

 

Содержание OPC-G1-DEV

Страница 1: ...ENGLISH English Version...

Страница 2: ...communications card OPC G1 DEV Read them in conjunction with this manual as necessary RS 485 Communication User s Manual FRENIC MEGA Instruction Manual The materials are subject to change without noti...

Страница 3: ...re to install the front cover before turning the inverter s power ON Do not remove the cover when the inverter power is ON Otherwise an electric shock could occur Do not operate switches with wet hand...

Страница 4: ...s The following icons are used throughout this manual This icon indicates information which if not heeded can result in the product not operating to full efficiency as well as information concerning i...

Страница 5: ...bly Instances Selection and Setup 17 7 2 1 Basic Speed Control Instance 17 7 2 2 Extended Speed Control Instance factory default 18 7 2 3 Fuji Drive Assembly Instance 19 7 2 4 User Defined Assembly In...

Страница 6: ...ownload from our website at http web1 fujielectric co jp Kiki Info EN User index html Fuji Electric FA Components Systems Co Ltd Technical Information Before downloading you are requested to register...

Страница 7: ...address MAC ID ranging from 0 to 63 Before accessing the DIP switch make sure that the inverter is turned OFF The default configuration of the DIP switch at factory shipment is Data rate 500 kbps Nod...

Страница 8: ...eing offline Blinks in green Online DeviceNet cabling correct and communications card not communicating on the DeviceNet network Waiting for a request from the master Lights in green Connection establ...

Страница 9: ...orm the wiring for the main circuit terminals and control circuit terminals 1 Remove the front cover from the inverter and expose the control printed circuit board control PCB As shown in Figure 3 1 t...

Страница 10: ...to determine the mounting position Insert connector CN1 on the communications card into the corresponding port on the inverter s control PCB Note Be sure to follow the order of and Inserting CN1 firs...

Страница 11: ...ng Completed on B port 3 2 Removing the Communications Card Remove the two screws that secure the communications card and pull the release knob shown above to take the communications card out of the i...

Страница 12: ...ced insulation is not applied Therefore if a control signal wire comes into direct contact with a live conductor of the main circuit the insulation of the cover might break down which would expose the...

Страница 13: ...out on DeviceNet Terminal Block Pin ID Color of Wire Sheath Pin Assignment Description 1 Black V Power supply 24 VDC side 2 Blue CANL Signal line side 3 Metallic SD Cable shield 4 White CANH Signal li...

Страница 14: ...r inverters with a capacity of 22 kW or below Pass the wires from the communications card between the control circuit terminal block and the front cover In the case of 0 4 kW For inverters with a capa...

Страница 15: ...l problem with your system setting y98 3 is recommended 1 After configuring the function code o31 or o32 restart the inverter to validate the new settings For details about these function codes refer...

Страница 16: ...ions card should be 10 ms or longer If a single inverter is connected to a master the cycle should be 10 ms or longer if two inverters are connected 5 ms or longer To minimize the data conflicts and m...

Страница 17: ...Speed Control Input Factory default 2 o32 101 101 Fuji Drive Assembly Input 2 o32 103 103 User Defined Assembly Input 4 o32 105 Input from inverter to master 105 Response to Function Codes Access Requ...

Страница 18: ...ference upper byte r min Run Forward 1 Run forward command Fault Reset 1 Reset the alarm condition Speed Reference Speed command in r min 2 Input from inverter to master o32 70 Instance byte bit 7 bit...

Страница 19: ...ce in r min 2 Input from inverter to master o32 0 or 71 Instance byte bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0 0 At Reference Ref FromNet Ctrl FromNet Ready Running Reverse Running Forward Faul...

Страница 20: ...X8 and X9 depends upon the product specifications of the FRENIC MEGA inverter For details refer to the FRENIC MEGA Instruction Manual Chapter 5 FUNCTION CODES 2 Input from inverter to master o32 101 I...

Страница 21: ...ike assignment of the same function code above if S01 S05 and S19 are assigned to o40 to o43 at the same time only the one assigned to the smallest o code number becomes effective and all the rest wil...

Страница 22: ...ode type shown in Table 7 2 and number in a 4 digit hexadecimal notation Table 7 2 Function Code Type Type Type Code Function Code Type Type Code Function Code S 2 02h Command function data J 14 0Eh A...

Страница 23: ...n Table 7 2 Access to function code write data Data to write into function code specified by bytes 4 and 5 Whether the inverter has terminals X8 and X9 depends upon the product specifications of the F...

Страница 24: ...ntry range error Attempted to write data out of the range 0F Function code data being written Requested to write to a function code being written 21 No function code in reading Attempted to read from...

Страница 25: ...viceNet are enabled 61 00 08 07 Response The motor is running forward and accelerating The actual speed is increasing 74 04 Request Run forward command Speed command 1800 r min 0708h The run command a...

Страница 26: ...nse The motor is running backward in the reverse direction and accelerating The actual speed is increasing 78 04 Request Run reverse command Speed command 1800 r min 0708h The run command and speed co...

Страница 27: ...nverter o31 0 or 21 word bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 bit 0 0 Net Ref Net Ctrl Fault Reset Run Reverse Run Forward 1 Speed Reference r min 2 Input from inverter to master o32 0 or 71 word b...

Страница 28: ...specified by o51 7 4 5 Access to Function Codes 1 Request for access to function codes from master to inverter o31 104 word bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 bit 0 0 RST XR XF Access code X9 X8...

Страница 29: ...s a group of read only variables Instance Attribute Name Description Value hex R W Data size 1 01 Vender ID Manufacturer s ID code 013F 319 Fuji Electric Group R Word 02 Device Type Applied device pro...

Страница 30: ...verter running 05 During deceleration 06 Stop due to communication broken 07 Tripped R Byte 07 Running1 Running forward 00 Stopped Running reverse 01 Running forward R Byte 08 Running2 Running reverse...

Страница 31: ...Output voltage V Output voltage R Word 12 hex AccelTime Acceleration time ms 0 to 65535 ms R W Word 13 hex DeccelTime Deceleration time ms 0 to 65535 ms R W Word 14 hex LowSpdLimit Lower limit speed...

Страница 32: ...99 M99 Communication function code M99 0 to FFFF R Word 04 01 F01 Inverter function code F01 0 to FFFF R W Word F codes 63 hex 99 F99 Inverter function code F99 0 to FFFF R W Word 05 01 E01 Inverter...

Страница 33: ...X codes 63 hex 99 X99 Communication function code X99 0 to FFFF R Word 12 18 01 Z01 Communication function code Z01 0 to FFFF R Word Z codes 63 hex 99 Z99 Communication function code Z99 0 to FFFF R W...

Страница 34: ...not exist Access to a nonexistent object Correct the contents of the Class 1F See blow Vender specific error Error unique to vendor See below 02 No function code in writing Attempted to write to a no...

Страница 35: ...cified by o28 ignore the communications error After the timeout decelerate to a stop and trip with er5 Same as above 13 Immediately run command OFF No er5 trip 14 Force to rotate the motor in forward...

Страница 36: ...tion error er5 7 07H Overvoltage during deceleration 0u2 36 24H Operation protection er6 8 08H Overvoltage during running at constant speed or stopped 0u3 37 25H Tuning error er7 10 0AH Undervoltage l...

Страница 37: ...in red er5 alarm has occurred The cable was broken during communication The I O scan interval is too short 5 The NS LED would not light The node address for the communications card is improper The cab...

Страница 38: ...nverter is to be used in such an environment install it in a dustproof panel of your system 12 2 DeviceNet Specifications Item Specifications Network input voltage 11 to 25 V Network power consumption...

Страница 39: ...MEMO...

Страница 40: ...up and operating of the DeviceNet communications card for the FRENIC MEGA series of inverters Please feel free to send your comments regarding any errors or omissions you may have found or any suggest...

Страница 41: ...o jp fcs Fuji Electric FA Components Systems Co Ltd Mitsui Sumitomo Bank Ningyo cho Bldg 5 7 Nihonbashi Odemma cho Chuo ku Tokyo 103 0011 Japan Phone 81 3 5847 8011 Fax 81 3 5847 8172 URL http www fuj...

Отзывы: