12.1 General Specifications
Install the inverter equipped with the communications card in an environment that satisfies the requirements
listed below.
Item
Specifications
Site location
Indoors
Surrounding temperature
Refer to the FRENIC-MEGA Instruction Manual, Chapter 2.
Relative humidity
5 to 95% (No condensation)
Atmosphere
The inverter must not be exposed to dust, direct sunlight, corrosive gases,
flammable gases, oil mist, vapor or water drops.
Pollution degree 2 (IEC60664-1)
(Note)
The atmosphere can contain a small amount of salt.
(0.01 mg/cm
2
or less per year)
The inverter must not be subjected to sudden changes in temperature that will
cause condensation to form.
Altitude
1,000 m max.
Atmospheric pressure
86 to 106 kPa
Vibration
Refer to the FRENIC-MEGA Instruction Manual, Chapter 2.
(Note) Do not install the inverter in an environment where it may be exposed to lint, cotton waste or moist dust or dirt
which will clog the heat sink of the inverter. If the inverter is to be used in such an environment, install it in a
dustproof panel of your system.
12.2 DeviceNet Specifications
Item
Specifications
Network input voltage
11 to 25 V
Network power consumption
75 mA at maximum (24 VDC)
(Note) The network power is supplied by an external power source.
No. of nodes connected
64 at maximum (including the master)
MAC ID
0 to 63
Insulation
500 VDC (photocoupler insulation)
Transmission rate
500 kbps/250 kbps/125 kbps
Transmission rate
500 kbps
250 kbps
125 kbps
Trunk line length
100 m
250 m
500 m
Drop line length
6 m
6 m
6 m
Maximum cable length
(Trunk line: thick cable
Drop line: thin cable)
Total length of drop lines
39 m
78 m
156 m
Messages supported
1. I/O Message (Poll, Change of State)
2. Explicit Message
Vendor ID
319 (Fuji Electric Group)
Device type
AC drive (code: 2)
Product code
9219
Model name
OPC-G1-DEV
Applicable device profile
AC Drive
No. of input/output bytes
Selectable between 4 and 8 bytes for input and output (independently)
Applicable DeviceNet
Specifications
CIP Specifications Volume 1, Edition 2.2 Japanese version and Volume
3, Edition 1.1 Japanese version
(Certified by ODVA Japan for Conformance Test Version 20)
Node type
Group 2 only server