[Display screen of the enhanced communication module on start-up]

It displays model code/serial code.

It displays the connected module-type 

temperature controller.

It  displays  St.  No.  for  enhanced 

communication. (

*

Note that this is 

different from the St. No. of the loader 

communication port)

Note

Error is displayed if the module-type temperature controller is not connected properly.

[Error display]

Содержание PUM

Страница 1: ...nual Contents 1 About the copyright of this software 3 2 Outline 3 3 Operating environment 3 4 Installing uninstalling the software 4 Installation 4 Uninstallation 6 5 Connecting your PC to the module...

Страница 2: ...2 INP TN5A1634 E...

Страница 3: ...mperature controllers The PV SV and MV trend can also be displayed as an auxiliary tool for tuning the module type temperature controllers Unless otherwise specified the parameter loader for module ty...

Страница 4: ...ake sure to conduct to uninstall it Installation Install the parameter loader for PUM on your PC 1 Open the PUM loader folder which was downloaded and double click PUMLoader Installer exe Note Please...

Страница 5: ...ck To stop installation click Cancel Note When you use Windows7 do not install the parameter loader to C Program Files Otherwise parameter loader for PUM may not be operated properly 5 Confirm the ins...

Страница 6: ...top installation click Cancel 7 Click Finish Uninstallation 1 Windows XP Control panel C Program Add Delete from the start menu to uninstall the software 2 Windows 7 Select Control panel C Program fro...

Страница 7: ...he parameters of the enhanced communication module connect the loader connecting cable to the loader communication port of the enhanced communication module Connection with RS 232C Provide the optiona...

Страница 8: ...e to turn off the power of the module type temperature controllers before making connections 4 Set the station number configuration switches of the connected module type temperature controllers as 1 2...

Страница 9: ...8 Do1 Do2 Do3 Do4 Do5 Do6 Do7 Do8 STATION 4 3 2 1 0 F E D C B A 9 8 7 6 5 STATION 4 3 2 1 0 F E D C B A 9 8 7 6 5 LOADER PUM E PWR COM Di1 Di2 Di3 Di4 Di5 Di6 Di7 Di8 Do1 Do2 Do3 Do4 Do5 Do6 Do7 Do8 W...

Страница 10: ...9 8 7 6 5 LOADER PUM A PWR COM OUT1 OUT2 OUT3 OUT4 STATION 4 3 2 1 0 F E D C B A 9 8 7 6 5 STATION 4 3 2 1 0 F E D C B A 9 8 7 6 5 PWR BUS RX1 TX1 RX2 TX2 LOADER PUM C LOADER PUM A PWR COM OUT1 OUT2 O...

Страница 11: ...aunched and click OK If you click Cancel parameter loader for PUM is end 2 Click 1 Select the module type of temperature controller to be launched 2 Startup mode is indicated Screen of control event a...

Страница 12: ...tart up Initial values startup mode P 13 Module data reception launch mode P 19 File selection startup mode P 17 Note In module type selection screen in case you select the module type selection diffe...

Страница 13: ...e setting Make sure to conduct this function under a situation where PUM is not connected to PC 1 In Startup mode screen select Initial values startup mode and click OK Screen of control event analog...

Страница 14: ...ation No to be set model code setting screen appears Set the last 10 digits of type code and click Check button When registration is completed type code will be indicated at A in model code setting an...

Страница 15: ...ss communication screen of station definition is not indicated and model code setting appears Enhanced communication module Mitsubishi program less communication has the fixed model code therefore do...

Страница 16: ...e setting appears ProfiBUS communication module ProfiBUS communication has the fixed model code therefore do not change the model code setting and just click Check button and then click OK button afte...

Страница 17: ...ng file stored previously as follows 1 Select File selection startup mode on the Startup mode screen and then click OK The display screen of the control event analog module on start up 2 Click 1 Click...

Страница 18: ...N5A1634 E 2 On the File selection startup mode screen select the file or the parameter setting stored previously and then click Open 2 Click 1 Select The PUM loader PUM parameters Support screen appea...

Страница 19: ...cted module type temperature controllers as follows 1 On the Startup mode screen select Module data reception launch mode and then click OK The display screen of the control event analog module on sta...

Страница 20: ...s the Esc key on the keyboard to cancel reading Note Approximately 20 seconds are required to read the parameter settings per module type temperature controller Do not perform other communication oper...

Страница 21: ...he Startup mode screen check Module connection designation and click OK 3 Click 1 Click 2 Check 2 Check the St No of the module type temperature controller to be read on the Station definition screen...

Страница 22: ...he keyboard to cancel reading Note Approximately 20 seconds are required to read the parameter settings per module type temperature controller Do not perform other communication operations while the s...

Страница 23: ...the File menu Click 2 Set required items on the Initial setting screen and then click OK Click Select COM port Baud rate 19200 Fixed Data length 8 Fixed Parity None Fixed Stop bit 1 Fixed Connection C...

Страница 24: ...INP TN5A1634 E Note The Online Offline setting can be made only when startup is performed by selecting Module connection designation on the Startup mode screen The setting is always Offline on start...

Страница 25: ...ers can be checked trend can be displayed and parameters can be copied PUM loader PUM Parameters Support screen On the PUM loader PUM Parameter Support screen parameter tree is displayed on the left a...

Страница 26: ...P TN5A1634 E The display screen of the enhanced comm module Mitsubishi s programless comm on start up Parameters are displayed Parameter tree is displayed Set values are displayed Blank cell cannot be...

Страница 27: ...INP TN5A1634 E 27 The display screen of the enhanced comm module Profibus comm on start up Parameters are displayed Parameter tree is displayed Set values are displayed Blank cell cannot be set...

Страница 28: ...ced comm module Ethernet comm on start up Parameter are displayed Parameter tree is displayed Set values are displayed Blank cannot be set Device size setting for setting monitor area during mapping c...

Страница 29: ...ght double click the setting to be changed 1 Select the parameter group from the Parameter tree 2 Double click the setting to be changed 2 Set a desired value on the Please set the value window and th...

Страница 30: ...be set Some values banned setting are included in the setting range displaied in the enhanced communication module Refer to the detailed parameter manual in the relevant parameters P 36 about the val...

Страница 31: ...TN5A1634 E 31 Favorite Frequently used parameters can be set in Favorite in the parameter tree screen on the left side Up to 200 parameters per module can be registered Displays parameters set in Favo...

Страница 32: ...rameters Support screen on P 25 right click the parameter you want to register in Favorite and then click Favorite Add Delete 2 Click Press the F2 key on the keyboard while a parameter is selected on...

Страница 33: ...e Favorite tree on the PUM loader PUM Parameters Support screen on P 25 and then click Favorite Add Delete 2 Click 1 Right click Press the F2 key on the keyboard while a parameter is selected on the p...

Страница 34: ...Favorites Files Save A from Data D menu Save As dialog appears input a file name and then click Save S Open favorites file 1 In the screen of PUM Parameters Support P 25 select the Favorites File Ope...

Страница 35: ...lay ON and OFF Parameter display on the setting screen on the right side can be changed between ON and OFF Parameters set as OFF are not displayed on the setting screen on the right side Parameters se...

Страница 36: ...M loader PUM Parameters Support screen on P 25 and click Display ON OFF 2 Click 1 Right click You can also press the F4 key on the keyboard while the parameter is selected on the parameter tree screen...

Страница 37: ...de 1 Select a parameter from the parameter tree screen on the left side of the PUM loader PUM Parameters Support screen on P 25 and then right click the setting that displays a related parameter on th...

Страница 38: ...n the Relevant parameters screen Displays related parameters Setting change can also be made Click to display detailed manual of the parameter To display detailed manual of the parameter Click Manual...

Страница 39: ...ged the change can be written into the module type temperature controller 1 Select Initial setting on the File menu of the PUM loader PUMP Parameters Support screen on P 25 Click 2 Select Online on th...

Страница 40: ...hanged parameter are read Reading takes approximately 20 seconds per module type temperature controller If a parameter that changes its value when processing is exited such as auto tuning start comman...

Страница 41: ...rom the Tool menu of the PUMP loader PUM Parameters Support screen on P 25 Click 2 Check the composition of the module type temperature controller on the Module composition screen Display screen of th...

Страница 42: ...de serial code It displays the connected module type temperature controller It displays St No for enhanced communication Note that this is different from the St No of the loader communication port Not...

Страница 43: ...troller currently edited can be checked 1 Select Model composition from the Tool menu of the PUM loader PUM Parameters Support screen Click 2 Select a desired model code on the Display model code scre...

Страница 44: ...44 INP TN5A1634 E Display screen of the enhanced communication module on start up Click...

Страница 45: ...ool menu of the PUM loader PUM Parameters Support screen on P 25 Click 2 Set required items on the Trend selection screen and then click Trend Disp 2 Set the duration from the time when sampling is co...

Страница 46: ...s required select time for display format in Excel cell format setting change it into desired display format and then save the data The first data at the start of trend display may differ from the act...

Страница 47: ...the Enhanced comm module Mitsubishi s programless comm Enhanced comm module Profibus comm Enhanced comm module Ethernet comm on the module type selection Copying between channels 1 Select Parameter co...

Страница 48: ...indow Click To cancel parameter copying Click Cancel In Ch copy the data is copied only within the station specified in From St Ch No Note Make sure that the channel No on the left side becomes smalle...

Страница 49: ...Select Parameter copy C from the Tool T menu of the PUM loader PUM Parameters Support screen on P 25 Click 2 Click the St copy tab on the Parameter copy screen Click To copy event module parameters b...

Страница 50: ...ncel the parameter copy Click Cancel Follow the same procedure for copying parameters between stations Event Note Be sure not to specify station No that has not been defined Otherwise an erroneous val...

Страница 51: ...CTRL C or right click to indicate the Menu and select Copy C 2 Paste Pate the parameter copied by copy function Select the parameter to be pasted Press CTRL V or right click to indicate the Menu and s...

Страница 52: ...or copy or paste either way it is undoable for one time only 1 Press CTRL Z or right click to open Menu and click UnDo Z Undo function can conduct to return the last changed part to previous action re...

Страница 53: ...used when you select Enhanced communication module Mitsubishi program less communication or ProfiBUS communication module 1 Click Station No change C from Data in main menu or right click in parameter...

Страница 54: ...lect the changed station No and then click OK Note If you set the existing station No to the station No after change station No is overwritten Additionally station No before change will be deleted UnD...

Страница 55: ...ed communication module Mitsubishi program less communication or ProfiBUS communication module ProfiBUS communication or Ethernet communication module Ethernet communication this function can not be u...

Страница 56: ...ndicate the menu and click Station No Delete X 2 To delete the station number dialog is indicated select the station No and click OK 3 When confirmation message to delete the station appears click YES...

Страница 57: ...munication Enhanced comm module Ethernet comm Setting area 1 to 712 Monitor area 1 to 712 ProfiBUS communication module ProfiBUS communication Output area 1 to 108 Input area 1 to 108 1 Select the par...

Страница 58: ...compare current setting parameter to initial data or connected PUM Compare initial data 1 Click Compare Initial data I from Data in the menu or right click to indicate the menu and then click Compare...

Страница 59: ...5A1634 E 59 Compare Module Data 1 Click Compare Module data M from Data in the menu or right click to indicate the menu and then click Compare Module data M 2 Select station numbers to compare and cli...

Страница 60: ...be compared to PUM When you press ESC key during operation of comparison operation will stop in the middle of comparison In this case parameter may not be indicated properly Upload P 62 the current pa...

Страница 61: ...UM Parameters Support screen on P 25 Click 2 Set necessary items on the Parameter list screen and then click Print or CSV Disp Select a module type temperature controller to be printed or displayed No...

Страница 62: ...n A4 paper in vertical orientation fixed The setting display of the PUM parameter loader and the display of the printing CSV output result may not be the same Example If the PUM parameter loader displ...

Страница 63: ...PUM data transmit U from the Data D menu of the PUM loader PUM Parameters Support screen on P 25 Click Proceed to2 when selected the control event analog on the module type selection Proceed to3 when...

Страница 64: ...type temperature controllers to be uploaded on the Station definition screen and then click OK 1 Check 2 Click Proceed to4 Note Do not check the box of the module not connected 3 Click OK on the PUM l...

Страница 65: ...the Save as screen and then click Save 1 Select the file in which the parameter setting is to be saved 2 Click Note Approximately 20 seconds are required for uploading per module type temperature con...

Страница 66: ...PC PUM data transmit D from the Data D menu of the PUM loader PUM Parameters Support screen on P 25 Click Proceed to2 when selected the control event analog on the module type selection Proceed to3 w...

Страница 67: ...re controllers to be downloaded on the Station definition screen and then click OK 1 Check 2 Click Note Do not check the box of the module not connected To cancel downloading Click Cancel 3 Click OK o...

Страница 68: ...ding Do not turn off the power of the module type temperature controller while downloading Do not pull out the loader connection cable while downloading Do not carry out downloading with the auto tuni...

Страница 69: ...pen from the Data menu of the PUM loader PUM Parameters Support screen on P 25 Click 2 Click OK on the PUM loader screen Click OK to save the parameter setting currently selected and go to 3 Click Not...

Страница 70: ...the parameter setting is to be saved on the Save as screen and then click Save S 1 Select the file in which the data is saved 2 Click 4 Select the desired file on the Open screen and then click Open 2...

Страница 71: ...ter settings can be saved in a file 1 Select Save from the Data menu of the PUM loader PUM Parameters Support screen on P 25 Click 2 Select the file in which the parameter settings are to be saved on...

Страница 72: ...rom the File menu of the PUM loader PUM Parameters Support screen on P 25 Click 2 Click Yes on the Exit window Click Yes to save the parameter setting currently selected and go to 3 Click Not to save...

Страница 73: ...run up to 4 PUM loaders at the same time When you run the 2nd PUM loader message appears and click YES Y PUM loaders will be multi launched Note When you conduct the multi launcher function of PUM loa...

Страница 74: ...tion between modules Parameters can not be changed RS 485 communication permission is set to Read only Change the setting to Readable Writable The parameter input value tried to write the value out of...

Страница 75: ...e display is not updated Click the parameters on the parameter tree display on the left side of the screen to update the tree Communication port does not open is displayed Multiple communication progr...

Страница 76: ...responding parameter version Unsupported Use the parameter version marked Character string such as 01A Operable parameter loader version differs depending on the revision No of PUM series Check the re...

Отзывы: