Safety Precautions

Before using this product, the user is requested to read the following precautions carefully to ensure the

safety. Safety precautions must be taken by every user to prevent accidents.

The safety requirements are classified into “warning” and “caution” according to the following interpreta-

tions:

Warning

Suggesting that the user's mishandling can 
result in personal death or serious injury.

Caution

Suggesting that the user's mishandling can result 
in personal injury or damage to the property.

“Any control system design should take into account that any part of the system has the potential to fail”.

“The most dangerous condition of the system equipped with this product is continued heating, and the ma-

chine should be designed to automatically stop heating even if alarm is not issued at the time of failure of this

product or due to any other reason”.

The following are the most common cases where continued heating cannot be detected with this product.

1) Failure to issuing an alarm even when this product fails

2) Disengagement of the temperature sensor from the system

3) A short circuit in the thermocouple wiring

In any application where physical injury or destruction of equipment might occur, we recommend the instal-

lation of independent safety equipment, with a separate temperature sensor, to disable the heating circuit in

case of overheating.

Digital thermostat alarm signal is not designed to function as a protective measure in case of product failure.

WARNING

Over-temperature Protection

Содержание PAS3

Страница 1: ...6201 6202 Fax 81 42 585 6187 6189 http www fic net co jp Instruction Manual Details for operation method and the related documents Before using the controller check if the type and specifications are...

Страница 2: ...em equipped with this product is continued heating and the ma chine should be designed to automatically stop heating even if alarm is not issued at the time of failure of this product or due to any ot...

Страница 3: ...completed Be sure to check that the distance is kept to avoid electric shock or firing before turning the power ON Keep away from terminals while the circuit is energized in order to avoid an electric...

Страница 4: ...and noise A place where the unit is exposed to direct sunlight A place where the heat may be accumulated due to the radiation of heat 2 2 Cautions on installation on panel Insert the mounting bracket...

Страница 5: ...5 Standard Vertical mounting flush on the panel This product is horizontal When mounting this product on tilted surface the maximum tilt angle is 30 degree from vertical...

Страница 6: ...ortened if full capacity load is connected to the alarm output relay If inductive load such as magnetic switches connected as a alarm output load it is recommended to use Z Trap manufactured by Fuji E...

Страница 7: ...fication Confirming that the delivered product is equal to the ordered one Outline dimensions Panel cutout dimensions Mounting method on the panel Basic operation method Set value change method List o...

Страница 8: ...el thickness 1 t 8 48 85 84 34 2 1 4 PV SET1 SET2 ALM1 ALM2 22 Panel cutout dimensions Unit mm For mounting close together n controllers For separate mounting Note Watertight feature is unavailable if...

Страница 9: ...e of 0 4N m Terminal Connection Diagram 100 to 240 Vac Designation of Wiring Material Wire Gauge AWG28 0 1mm2 to AWG16 1 25mm2 Strip off length 5 to 6 mm Rod terminal Dimension of exposed conductor se...

Страница 10: ...et value 1 or alarm set value 2 is displayed in the Operation mode level 1 2 Parameter name or set value is displayed at the time of setup of various parameters level 2 3 4 3 Various warnings are disp...

Страница 11: ...ressed The increase decrease speed changes when the or key is kept pressed 1 Select a parameter you want to set by pressing the or key 2 Press the key to display the parameter set value 3 Pressing the...

Страница 12: ...4 parameter block When indicating the process value PV SEL Press the once 1 Select the level to which move is to occur by the length of time during which the SEL key is pressed 2 Setup of the alarm se...

Страница 13: ...solute value Without Relay de energization Upper limit Lower limit Absolute value With Relay de energization Absolute value With Relay de energization Turn OFF ON the power for the main unit once afte...

Страница 14: ...or input and thermocouple input It is fixed depending on what was specified at the time of purchase 3 If the input signal was changed the measuring range should be changed to a value that corresponds...

Страница 15: ...k Select whether parameter setup change is permitted or not LoC 0 Setup change is permitted for all parameters LoC 1 No setup change is permitted for all parameters LoC 2 Alarm set value 1 ST1 and ala...

Страница 16: ...ayed depending on the type Indicated by 4 The accuracy of alarm delay time and of power ON delay time is less than 1 second 5 A difference of 1 C may arise between the indication and the alarm output...

Страница 17: ...able For details see Table 1 Alarm action type codes ON delay setting time ON Alarm OFF ON OFF ON OFF Without ON delay function With ON delay function ON delay function Energizing de energizing functi...

Страница 18: ...ions of alarm of Digital Thermostat is prepared Please inquire us when you use this function Caution PV Process value Power ON Lower limit alarm Lower limit alarm with hold Power ON Power OFF Output b...

Страница 19: ...t L OFF w When burn out direction brn is set at upper limit H ON Case of lower limit alarm setup q When burn out direction brn is set at lower limit L ON w When burn out direction brn is set at upper...

Отзывы: