108
Figure 101: Assign Name
9.5.7.7
Save the Configuration
The hardware configuration is now complete. Save and perform any necessary compilation of the
configuration. Download the application and configuration to the PLC. The PLC application program can
then be started. Please consult with the vendor of your PROFINET PLC software for additional
programming and configuration details.
9.5.8 GE Proficy Configuration Example
The following example will use GE Proficy Machine Edition SIM11 to demonstrate the basic procedure
for configuring a PROFINET device. The example will not cover all features of Proficy. Any questions
regarding Proficy (or similar configuration software) must be directed at the vendor of the software.
This example assumes that there is already an existing Proficy project with the desired PLC.
9.5.8.1
Register the GSDML File
Open the Proficy project. In the
Navigator
panel, right-click
Profinet Controller
and select
Add IO-
Device…
as shown in Figure 102.