series
USER’S MANUAL
Analog Unit
FEH527d
Страница 1: ...series USER S MANUAL Analog Unit FEH527d...
Страница 2: ...of units in the MICREX SX series SPF User s Manual Instructions Standard MICREX SX series SPF FEH524 Describes the memory specifications and instructions specific to SPF series User s Manual Instruct...
Страница 3: ...terminals and exposed metal portion while the power is turned ON It may result in an electric shock to the operator Turn OFF the power before mounting dismounting wiring maintaining or checking otherw...
Страница 4: ...operation might occur Before touching the PLC discharge any static electricity that may have been collected on your body To discharge it touch a grounded metallic object Static electricity might cause...
Страница 5: ...X02 TC Thermocouple input 2 channels NA0AX16 TC Thermocouple input 16 channels NA0AX06 MRTC Analog input thermocouple input 6 channels NA0AX06 PT Resistance thermometer element input 6 channels July 2...
Страница 6: ...Analog input output unit Type NA0AW06 MR 2 19 2 3 4 Analog output board Type NA3AY02 MR 2 22 2 3 5 Analog input output board Type NA3AW03 MR 2 22 2 3 6 Thermocouple input unit Type NA0AX02 TC NA0AX06...
Страница 7: ...App 1 1 Appendix 1 1 1 Handling Upper Cover App 1 1 Appendix 1 1 2 Handling Printed circuit board inside unit App 1 3 Appendix 2 Circuit Isolation Block Diagram Appendix 2 1 Analog Input Unit NA0AX06...
Страница 8: ...istance thermometer element input 6 channels 1 1 Product List The SPF series analog unit and temperature measurement unit include the following models In this manual these models may be collectively r...
Страница 9: ...Moving average resolution for analog input only Thermocouple input unit Type NA0AX02 TC NA0AX06 TC NA0AX16 TC Thermocouple type moving average sampling period resolution unit Celsius or Fahrenheit Re...
Страница 10: ...dio frequency electromagnetic field 80 to 1000MHz 10V m 1 4 to 2 0 GHz 3V m 2 0 to 2 7 GHz 1V m IEC 61000 4 3 EFT B Electrical fast transient burst Equipment power I 0 power AC I O unshielded 2kV Data...
Страница 11: ...or individual channels by the program loader External wire connections 8 pole terminal block M3 x 2 Tightening torque 0 59 to 0 78 N m Applicable wire size AWG 22 18 Be sure to use shielded twisted pa...
Страница 12: ...erminal block M3 x 2 Tightening torque 0 59 to 0 78 N m Applicable wire size AWG 22 18 Be sure to use shielded twisted pair cables Status indication 5V power supply display ON when normal red Isolatio...
Страница 13: ...output value INT type Output cycle Synchronized with the scan of the main unit External wire connections 8 pole terminal block M3 x 2 Tightening torque 0 59 to 0 78 N m Applicable wire size AWG 22 18...
Страница 14: ...European style terminal block M2 x 1 Tightening torque 0 2 N m Applicable wire size AWG 28 16 Be sure to use shielded twisted pair cables Status indication None Isolation method Not isolated Occupied...
Страница 15: ...he scan of the main unit External wire connections 5 pole European style terminal block M2 x 1 Tightening torque 0 2 N m Applicable wire size AWG 28 16 Be sure to use shielded twisted pair cables Stat...
Страница 16: ...tions 8 pole European style terminal block M2 x 2 Tightening torque 0 2 N m 18 pole terminal block M3 x 2 Tightening torque 0 59 to 0 78 N m Applicable wire size AWG 28 16 AWG 22 18 Status indication...
Страница 17: ...ted pair cables Status indication 5V power supply display ON when normal red Isolation method Not isolated For the internal circuit see Appendix 2 Occupied words 6 words External power supply 24V DC 1...
Страница 18: ...g input voltage current The values in are the A D conversion values when 12 bits is selected for the resolution 4095 16383 0 10V 20mA A D conversion value INT type Analog input voltage current 1 The v...
Страница 19: ...nt The values in are the A D conversion values when 12 bits is selected for the resolution 4095 16383 0 5V 10mA 5V 10mA A D conversion value INT type Analog input voltage current The value in is the A...
Страница 20: ...mA 10V 20mA A D conversion value INT type Analog input voltage current The values in are the A D conversion values when 12 bits is selected for the resolution 8191 2047 0 10V 20mA 10V 20mA 8192 2048 A...
Страница 21: ...t voltage current D A conversion value INT type 3 0 to 10V 0 to 20mA when set at UNIPOLAR 2 0 to 5V 0 to 10mA when set at BIPOLAR 8191 5V 10mA 0V 0mA 8192 Analog output voltage current D A conversion...
Страница 22: ...IPOLAR 6 5 to 5V 10 to 10mA when set at BIPOLAR 8191 10V 20mA 0V 0mA 8192 Analog output voltage current D A conversion value INT type 16383 0 5V 10mA 5V 10mA Analog output voltage current D A conversi...
Страница 23: ...o 20mA when set at UNIPOLAR 8 10 to 10V 20 to 20mA when set at BIPOLAR 16383 0 10V 20mA 10V 20mA Analog output voltage current D A conversion value INT type 8191 0 10V 20mA 10V 20mA 8192 Analog output...
Страница 24: ...removed 2 Terminal block 1 Status indication LED Nameplate Expansion connector IN Expansion connector OUT 3 JP1 2 Terminal block 4 JP3 5 JP5 CH1 5 JP5 CH0 4 JP2 5 JP8 CH4 5 JP9 CH5 5 JP7 CH3 5 JP6 CH...
Страница 25: ...erminals for 24V DC power supply to operate the analog unit and analog input signal 3 JP1 Digital value range selection This jumper pin is used to set the digital value range 4 JP2 and JP3 Analog inpu...
Страница 26: ...s indication LED Nameplate Expansion connector IN Expansion connector OUT 2 Terminal block Pin layout of control board When the upper cover is removed Notes on mounting removing the upper cover and co...
Страница 27: ...Digital value range selection This jumper pin is used to set the digital value range 4 JPA and JPB Analog output range selection B U B U U B 5V 10V U B 5V 10V U B 5V 10V U B 5V 10V U B 5V 10V U B 5V 1...
Страница 28: ...inal block 1 Status indication LED Nameplate Expansion connector IN Expansion connector OUT 2 Terminal block Pin layout of control board When the upper cover is removed Pin layout of I O board When th...
Страница 29: ...to set the digital value range for analog output upper side and analog input lower side U B Analog output Analog input U B Analog output Analog input 4 JPA and 5 JPB Analog output range selection U B...
Страница 30: ...used to select voltage or current for each channel I V I V When handling the setting pins on the printed circuit board be sure to turn OFF the unit power Securely mount them by using tweezers Signal r...
Страница 31: ...torque 0 2 N m For the wiring method see 2 4 Wiring 2 3 5 Analog input output board Type NA3AW03 MR 1 Names GND VO0 IO0 GND VI0 II0 VI1 II1 1 Terminal block 2 Functions 1 Terminal block These are term...
Страница 32: ...ndication LED Nameplate Expansion connector IN Expansion connector OUT 2 Terminal block 2 Terminal block NA0AX02 TC NA0AX16 TC NA0AX06 TC 1 Status indication LED 2 Terminal block 2 Terminal block 1 St...
Страница 33: ...ED 2 Terminal block These are terminals for 24V DC power supply to operate the unit and thermocouple input signal For the wiring method see 2 4 Wiring When performing wiring of NA0AX02 TC and NA0AX06...
Страница 34: ...connector IN Expansion connector OUT 2 Terminal block Status indication LED Status Specification PWR of resistance thermometer element input unit ON red While 5V DC power is normally supplied 2 Functi...
Страница 35: ...annels shall basically be short circuited 2 Ground shielded wires at one point on the PLC side Grounding resistance of 100 or less However when shielded wires had better be grounded on the external de...
Страница 36: ...2 Ground shielded wires at one point on the PLC side Grounding resistance of 100 or less However when shielded wires had better be grounded on the external device side due to the condition of externa...
Страница 37: ...ne point on the PLC side Grounding resistance of 100 or less However when shielded wires had better be grounded on the external device side due to the condition of external noise their ends on the PLC...
Страница 38: ...less However when shielded wires had better be grounded on the external device side due to the condition of external noise their ends on the PLC side must be open 3 Keep signal wires that go out of th...
Страница 39: ...et type NA0AX02 TC NA0AX06 TC NA0AX16 TC Multiplexer 24V DC 24V 24V TC15 TC15 TC1 TC1 TC0 TC0 NA0AX02 TC NA0AX06 TC NA0AX16 TC External power supply Thermocouple sensor Thermocouple sensor Thermocoupl...
Страница 40: ...r 24V 24V P5 P5 COM P1 P1 P0 P0 PT NA0AX06 PT PT 24V DC External power supply 1 When this unit is used under high noise environment ground grounding terminal grounding resistance of 100 or less 2 For...
Страница 41: ...6 channels NA0AY02 MR Analog voltage current output 2 channels NA0AW06 MR Analog voltage current input output Input 4 channels Output 2 channels NA0AX02 TC Thermocouple input 2 channels NA0AX06 TC The...
Страница 42: ...ut 1 channel Front board type NA3AY02 MR Analog voltage current output 2 channels Front board type 2 5 2 Expansion unit 2 Target type 21 4 4 2 4 5 4 4 90 80 97 90 3 7 5 19 5 2 5 3 Front board Target t...
Страница 43: ...e INT type WXo 3 CH3 A D conversion value INT type WYo 4 CH4 D A conversion value INT type WYo 5 CH5 D A conversion value INT type WXo 0 CH0 A D conversion value INT type WXo 1 CH1 A D conversion valu...
Страница 44: ...T7 Temperature conversion value INT type WXo 8 T8 Temperature conversion value INT type WXo 9 T9 Temperature conversion value INT type WXo 10 T10 Temperature conversion value INT type WXo 11 T11 Temp...
Страница 45: ...in unit Example of system configuration NA3AW03 MR Front board type NA0AX06 MR Main unit How to register units 1 Open the system definition screen and register the unit that is connected below the mai...
Страница 46: ...rd for the Module group type and NA3AW03 MR Mixed Analog 3CH from the Outline specification box Then click the OK button The unit is registered The front board is connected on the front of the main un...
Страница 47: ...times What does the 14 bits 12 bits of the resolution mean This means the resolution is 14 bits however the lower two bits are fixed to 0 The A D conversion value range is the same as for 14 bits as s...
Страница 48: ...ction 3 Programming 2 Click the Parameter button to display the Analog Input Unit parameter setting dialog box Set the resolution data format and moving average for each channel and then click the OK...
Страница 49: ...to 1800 C R 0 to 1800 C S 0 to 1700 C Moving average No moving average 2 4 or 8 times Sampling period High speed or low speed Unit Celsius or Fahrenheit How to set parameters 1 Right click the thermoc...
Страница 50: ...JIS Moving average No moving average 2 4 or 8 times Sampling period High speed 1 second or low speed 2 seconds Unit Celsius or Fahrenheit How to set parameters 1 Right click the thermocouple input uni...
Страница 51: ...e sure to eliminate static electricity Upper cover Lower case 2 Lightly turn the lower case of the unit and the upper cover in the direction of each arrow A small gap is made between one side of the l...
Страница 52: ...ver 1 Hold the lower case with the nameplate facing forward and the upper cover with the side having the larger notch up Then mount the upper cover straight on the lower case you will hear a clicking...
Страница 53: ...at the printed board fixing hole of the lower case 3 Pull the upper part of the lower case rightward and leftward detach the printed board from the fixing hole and then pull it out slowly 2 How to mo...
Страница 54: ...App 2 1 Appendix 2 Circuit Isolation Block Diagram Appendix 2 1 Analog Input Unit NA0AX06 MR Appendix 2 2 Analog Output Unit NA0AY02 MR...
Страница 55: ...App 2 2 Appendix 2 Circuit Isolation Block Diagram Appendix 2 3 Analog Input Output Unit NA0AW06 MR Appendix 2 4 Thermocouple Input Unit NA0AX02 TC NA0AX06 TC...
Страница 56: ...App 2 3 Appendix 2 Circuit Isolation Block Diagram Appendix 2 5 Thermocouple Input Unit NA0AX16 TC Appendix 2 6 Resistance Thermometer Element Input Unit NA0AX06 PT...
Страница 57: ...nt are subject to revision due to the modification of the product Fuji Electric Co Ltd Gate City Ohsaki East Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan E mail micrex sx fujielectric co...