Current program
status
Description
Parameter
display symbol
Name
Remark
Factory
default settings
1st to 8th
target SV
1st to 8th ramp
segment time
1st to 8th soak
segment time
Ramp-soak mode
STAT
SV-1
to
SV-8
TM1r
to
TM8r
TM1s
to
TM8s
Mod
Displays the Ramp-soak current status.
This parameter is only for display, and cannot set anything.
: OFF
to
: Under the 1st to 8th ramp operation
to
: Under the 1st to 8th soak operation
: Ends the program
0%FS
0.00
0.00
0
Sets the target value (SV) of each ramp segment
(Setting range:
to
)
Sets the ramp time for each segment
(Setting range: 0 to 99h 59min)
Selects the modes of ramp-soak function.
Set to "0" under normal conditions
No
symbol
appears
when
the
ramp-soak
model
is not
selected.
Sets the soak time for each segment
(Setting range: 0 to 99h 59min)
to
to
MOD
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Power-on start
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Output at the END
Continuous control
Continuous control
Continuous control
Continuous control
Standby mode
Standby mode
Standby mode
Standby mode
Continuous control
Continuous control
Continuous control
Continuous control
Standby mode
Standby mode
Standby mode
Standby mode
Output at OFF
Continuous control
Continuous control
Standby mode
Standby mode
Continuous control
Continuous control
Standby mode
Standby mode
Continuous control
Continuous control
Standby mode
Standby mode
Continuous control
Continuous control
Standby mode
Standby mode
Repeat operation
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
[MODE code list]
[Description of functions]
1. Power-on start: The ramp-soak operation starts to run
from the current PV value.
2. Output at END: The output status at the END of the
ramp-soak operation.
3. Output at OFF: The output status while the ramp-soak
operation is set to OFF.
4. Repeat operation: This function makes the ramp-soak op-
eration to continue after one cycle of ramp-soak opera-
tion is completed. At the event of Repeat operation: OFF,
the SV that is set in the final cycle is kept.
* Standby mode:
Output: control output OFF or -3%
Alarm: OFF
Control: OFF
[Ramp]
The segment in which the set value changes toward the tar-
get value.
[Soak]
The segment in which the set value is always the target value
and remains unchanged.
PV
SV-1
SV-2
SV-3
SV-4
TM1r TM1S TM2r TM2S TM3r TM3S TM4r TM4S
1st ramp
2st soak
2nd ramp
2nd soak
3rd soak
4th soak
3rd ramp
4th ramp
Power-on
start
Can be repeated