background image

 

– 9 – 

 

6-8

 

Alarm (Ch8)

 

Sets the detect conditions for each type of alarm.

 

6-9

 

Communication (Ch9)

 

Sets the communication conditions towards the host computer.

 

6-10

 

PFB (Ch10)

 

Changes settings to use valve control.

 

6-11

 

Password Setup (Ch11)

 

Sets the password. Passwords can be set at three levels.

 

"

 

 

 

 

d

d

d

di

i

i

i1

1

1

1

 

" (dil)

DI-1 function 
selection

Sets the 
function of 
DI-1

0 (No function)

 

1 (Switchover between STBY ON/OFF)
2 (Switchover between Auto/Manual)
3 (Switchover between Local/Remote)

 

4 (No function)
5 (No function)
6 (Start AT (standard))
7 (Start AT (low PV))
8 (No function)
9 (No function)
10 (Ramp SV ON/OFF)
11 (Ramp SV HOLD)
12 (Ramp soak OFF)
13 (Ramp soak RUN/HOLD)
14 (No function)
15 (Latch release (all))
16 (Latch release (DO1))
17 (Latch release (DO2))
18 (Latch release (DO3))
19 (Latch release (DO4))
20 (Latch release (DO5))
21 (Start timer (DO1))
22 (Start timer (DO2))
23 (Start timer (DO3))
24 (Start timer (DO4))
25 (Start timer (DO5))
26 (SV No. + 1)
27 (SV No. + 2)
28 (SV No. + 4)
29 (PID No. + 1)
30 (PID No. + 2)
31 (PID No. + 4)
32 (No function)
33 (No function)
34 (No function)
35 (SV No.+1, PID No.+1)
36 (SV No.+2, PID No.+2)
37 (SV No.+4, PID No.+4)
38 (Pattern No.+1) 
39 (Pattern No.+2) 
40 (Pattern No.+4) 
41 (Soft start)
42 (Ramp soak RUN)
43 (Ramp soak HOLD)

 

44 (Ramp soak RUN at DO1 startup)
45 (Ramp soak RUN at DO2 startup)
46 (Ramp soak RUN at DO3 startup)

 

47 (No function)
48 (No function)

0

 

(Note11)

 

"

d

d

d

di

i

i

i3

3

3

3

" (di3)

DI-3 function 
selection

Sets the 
function of 
DI-3

0 to 48

0

"

d

d

d

do

o

o

o1

1

1

1t

t

t

t

" (do1T)

Sets the DO1 
output event 
type

Sets the 
function of 
DO1

0 to 102

0

(Note3)

"

d

d

d

do

o

o

oP

P

P

P1

1

1

1

" (doP1)

Sets DO1 
option function

Assigns the 
four types of 
option 
functions in 
bit units

0000 to 1111

0000

"

d

d

d

do

o

o

o3

3

3

3t

t

t

t

" (do3T)

Sets the DO3 
output event 
type

Sets the 
function of 
DO3

0 to 102

0

"

d

d

d

do

o

o

oP

P

P

P3

3

3

3

" (doP3)

Sets DO3 
option function

Assigns the 
four types of 
option 
functions in 
bit units

0000 to 1111

0000

"

r

r

r

rm

m

m

mp

p

p

p

" (rMP)

ramp SV 
ON/OFF

Sets the 
ramp SV 
ON/OFF

oFF (ramp SV OFF)
on (ramp SV ON)

on

"

r

r

r

rm

m

m

mP

P

P

PL

L

L

L

" (rMPL)

Ramp SV- 
Decline

Sets the slope 
for a falling SV 
during ramp 
SV operations

0 to 100% FS

0°C

"

r

r

r

rm

m

m

mP

P

P

Ph

h

h

h

" (rMPh)

Ramp SV- 
Incline

Sets the slope 
for a rising SV 
during ramp 
SV operations

0 to 100% FS

0°C

"

r

r

r

rm

m

m

mP

P

P

PU

U

U

U

" (rMPU)

Ramp SV- 
slope units of 
time

Sets the unit 
of time for the 
slope during 
ramp SV 
operations

hoUr (slope temperature/hour)
Min (slope temperature/min)

hoUr

"

S

S

S

Sv

v

v

vt

t

t

t

" (SvT)

Ramp SV - SV 
display mode 
selection

Displays the 
SV during 
ramp 
operations or 
the SV goal 
value on the 
SV display

rMP (SV during ramp)
TrG (target SV)

rMP

"

[

[

[

[t

t

t

tr

r

r

rL

L

L

L

" (CTrL)

Control 
methods

Allows you to 
select the 
control 
method.

Pid (PID control)
FUZY (Fuzzy PID control)
SELF (Self-tuning control)
Pid2 (PID2 control)

Pid

Sections 
7-1 to
7-5
(Note18)

Parameter
display symbol

Parameter 
name

Function

Setting range

Initial 
value

Remarks

RST

RST

bit0 : output latch function
bit1 : error alarm function
bit2 : non-excitation output

 alarm function

bit3 : hold reset function

□□□□ 

□□□□ 

bit0 : output latch function

bit1 :  error alarm function

bit2 : non-excitation 

output alarm function

bit3 : hold reset function

RST

"

S

S

S

St

t

t

tm

m

m

md

d

d

d

" (STMd)

Start mode

Sets the 
operation 
mode when 
starting up

Auto (auto mode startup)
Man (manual mode startup)
Rem (remote mode startup)
STby (Standby make startup)

AUTo

Parameter
display symbol

Parameter name

Function

Setting range

Initial 
value

Remarks

"

A

A

A

A1

1

1

1h

h

h

hY

Y

Y

Y

" (A1hy)

ALM1 hysteresis

Sets the hysteresis 
for alarm output 1 
ON/OFF

0 to 50% FS

1°C

(Note3)

"

d

d

d

dL

L

L

LY

Y

Y

Y1

1

1

1

" (dLY1)

ALM1 delay

Sets the delay 
before detecting  
alarm output 1

0 to 9999 [sec/min]

0
(sec/min)

"

d

d

d

dL

L

L

L1

1

1

1U

U

U

U

" (dL1U)

ALM1 delay time 
units

Sets the delay time 
units for alarm 
output 1

sec (second)
Min (minute)

sec

"

A

A

A

A3

3

3

3h

h

h

hY

Y

Y

Y

" (A3hy)

ALM3 hysteresis

Sets the hysteresis 
for alarm output 3 
ON/OFF

0 to 50% FS

1°C

"

d

d

d

dL

L

L

LY

Y

Y

Y3

3

3

3

" (dLY3)

ALM3 delay

Sets the delay  
detecting for alarm 
output 3

0 to 9999 [sec/min]

0
(sec/min)

"

d

d

d

dL

L

L

L3

3

3

3U

U

U

U

" (dL3U)

ALM3 delay time 
units

Sets the delay time 
units for alarm 
output 3

sec (second)
Min (minute)

sec

"

h

h

h

hb

b

b

b1

1

1

1

" (hb1)

HB alarm set value 
for CT

Sets the heater 
burnout alarm 
detection value for 
CT

0.0 to 50.0A

0.0A

(Note10)

"

h

h

h

hb

b

b

b1

1

1

1h

h

h

h

" (hb1h)

HB alarm 
hysteresis for CT

Sets the heater 
burnout alarm ON/
OFF hysteresis for 
CT

0.0 to 50.0A

0.5A

(Note10)

"

h

h

h

hS

S

S

S1

1

1

1

" (hS1)

Load short-circuit 
alarm setting value 
for CT

Sets the heater 
load short-circuit 
alarm setting value 
for CT.

0.0 to 50.0A

0.0A

"

h

h

h

hS

S

S

S1

1

1

1h

h

h

h

" (hS1h)

Load short-circuit 
alarm hysteresis 
for CT

Sets the heater 
load short-circuit 
alarm ON/OFF 
hysteresis for CT.

0.0 to 50.0A

0.5A

"

l

l

l

lb

b

b

bT

T

T

Tm

m

m

m

" (LbTM)

Loop break 
detection time

Sets the time 
before detecting a 
broken loop

0 to 9999 sec

0 sec

"

L

L

L

Lb

b

b

bA

A

A

Ab

b

b

b

" (LbAb)

Loop break 
detection range 
(°C)

Sets the 
temperature range 
before detecting a 
broken loop

0 to 100% FS

10°C

Parameter
display symbol

Parameter name

Function

Setting range

Initial 
value

Remarks

"

S

S

S

St

t

t

tn

n

n

no

o

o

o

" (Stno)

ST No. setting

Sets the station 
number.

0 to 255 (0: 
unresponsive 
communication)

1

(Note15)

"

C

C

C

Co

o

o

oM

M

M

M

" (CoM)

Baud rate/
Parity setting

Sets the baud 
rate and parity 
check

96od (9600 bps/odd)
96Ev (9600 bps/even)
96no (9600 bps/none)
19od (19200 bps/odd)
19Ev (19200 bps/even)
19no (19200 bps/none)

96od

(Note15)

"

S

S

S

S[

[

[

[[

[

[

[

" (SCC)

Communication 
permissions

Sets whether or 
not overwriting is 
possible from the 
master side (PC, 
etc.)

r (read only permission)
rW (read and overwrite 
permission)

rW

(Note15)

Parameter
display symbol

Parameter name

Function

Setting range

Initial 
value

Remarks

"

P

P

P

PG

G

G

GA

A

A

AP

P

P

P

" (PGAP)

PFB dead band

Sets the PFB dead 
band

0.0 to 100.0%

5%

(Note8)

"

t

t

t

tr

r

r

rv

v

v

vL

L

L

L

" (TrvL)

Valve stroke time

Sets the full stroke 
time for the valve

5 to 180 sec

30 sec

(Note8)

Display

Parameter name

Function

Setting range

Initial 
value

Remarks

"

P

P

P

PA

A

A

AS

S

S

S1

1

1

1

" (PAS1)

Password1 setup

Sets password 1.

0000 to FFFF

0000

"

P

P

P

PA

A

A

AS

S

S

S2

2

2

2

" (PAS2)

Password2 setup

Sets password 2.

0000 to FFFF

0000

"

P

P

P

PA

A

A

AS

S

S

S3

3

3

3

" (PAS3)

Password3 setup

Sets password 3.

0000 to FFFF

0000

Parameter
display symbol

Parameter 
name

Function

Setting range

Initial 
value

Remarks

RST

Содержание Micro Controller X PXG4

Страница 1: ...ed for continuous and safe use of this equipment Some parts installed on this equipment have a limited life and or may deteriorate with age The warranty period for this unit including accessories is o...

Страница 2: ...auxiliary relay If the output operation frequency is high selecting a SSR SSC drive output type is recommended Proportionate cycles Relay output 30 seconds or more SSR SSC drive output 1 second or mo...

Страница 3: ...ontroller move it as least 30 mm away Cautions when wiring Start by wiring from the left hand terminals terminals 1 to 6 Use a screw that is the right size on terminals and tighten them with a torque...

Страница 4: ...ction 7 8 9 10 Relay output 13 14 Current output 13 14 SSR drive 3 4 14 13 Voltage output Control output 1 15 16 17 18 Thermocouple input 15 16 17 18 A B B Resistance bulb input 15 16 17 18 Current vo...

Страница 5: ...lay and Status Display In monitor mode the PV display shows item names while the SV display shows the input out put values For more details on P P P PA A A AS S S SS S S S PASS see 5 6 Key Lock and Pa...

Страница 6: ...E EF F F FE E E E FEFE is entered as P P P PA A A AS S S SS S S S PASS all of the channels OPE ch to DSP ch can be displayed and set This super password function is useful when you forget the set pass...

Страница 7: ...d d d d7 7 7 7 d7 Differential time 7 Sets the differential time 0 0 to 999 9 sec 60 0 sec h h h hy y y yS S S S7 7 7 7 hyS7 ON OFF control hysteresis 7 Sets the hysteresis when using the ON OFF cont...

Страница 8: ...5 Note1 r r r rt t t tF F F F rTF RSV input filter Sets the time constant for the RSV input filter 0 0 to 120 0 sec 0 0 sec Note1 fixed at 0 8bit PV input underflow 9bit PV input overflow 10bit underr...

Страница 9: ...it2 non excitation output alarm function bit3 hold reset function RST S S S St t t tm m m md d d d STMd Start mode Sets the operation mode when starting up Auto auto mode startup Man manual mode start...

Страница 10: ...et the PID parameter when using fuzzy control Setting fuzzy PID control 7 4 Self tuning Control Self tuning Control is a control which automatically calculate the value of PID under the condi tion tha...

Страница 11: ...ontrol equipment power t SV process value control loop close close open PV Point Set the following parameters before running auto tuning PV input type PV input upper limit PV input lower limit Decimal...

Страница 12: ...r r r r and set the ramp time 6 Display the soak time parameter t t t tm m m m1 1 1 1r r r r and set the soak time 7 Repeat steps 4 through 7 and set the remaining parameters MV MV1 MV2 MV1 MV2 MV lim...

Страница 13: ...er DO2 Starts the specified timer for DO2 2 2 2 23 3 3 3 Start timer DO3 Starts the specified timer for DO3 2 2 2 24 4 4 4 No function Do not set 2 2 2 25 5 5 5 No function Do not set 2 2 2 26 6 6 6 S...

Страница 14: ...ent 96 Time signal 26th segment 97 Time signal 27th segment 98 Time signal 28th segment 99 Time signal 29th segment 100 Time signal 30th segment 101 Time signal 31st segment 102 Time signal 32nd segme...

Страница 15: ...aud rate setting parameter C C C Co o o oM M M M and choose 9600 bps even 9 9 9 96 6 6 6e e e ev v v v This sets the baud rate to 9600 bps and the parity to even 3 Display communication permissions S...

Страница 16: ...value For dual control set S S S Sb b b bo o o o2 2 2 2 the same way 4 Press the key to set the value 1 Display the system menu S S S SY Y Y YS S S S C C C Ch h h h 7 7 7 7 2 Set both ramp SV decline...

Страница 17: ...V No 1 Display the operation menu o o o oP P P PE E E E C C C Ch h h h 1 1 1 1 2 Display the selected PID number S S S Sv v v vn n n n and choose di 3 Display the di function setting d d d di i i i1 1...

Страница 18: ...ent range C Measurement range F Smallest input increment C Input code Resistance bulb JIS IEC Pt 100 0 to 150 32 to 302 0 1 1 1 1 1 0 to 300 32 to 572 0 1 0 to 500 32 to 932 0 1 0 to 600 32 to 1112 1...

Страница 19: ...code is changed turn off the power once and then re start the controller before starting control Aln AL1 to AL3 show the alarm set values ALnh AL1h to AL3h show the alarm set values ALnL AL1L to AL3L...

Страница 20: ...Thermocouple input greatest one among 0 3 FS 1 digit and 1 C or 2 C Resistance bulb input greatest one among 0 3 FS 1 digit and 0 5 C mV input voltage input current input 0 3 FS 1digit Indication res...

Отзывы: