Preface 

 

Thank you for purchasing our Copy Adapter "CPAD-C1A." 

 

The Copy Adapter can copy and set function codes and their data stored in FRENIC-Mini series of inverters into other ones while the inverters are in 
a stop state. 

 

Connecting the Copy Adapter to the connector provided for an RS485 communications card (option) on the inverter allows you to copy (by reading 
data in the inverters and writing them into other ones), set, and monitor function codes and their data. 

 

The Copy Adapter can store and manage up to 10 function code data blocks copied from 10 inverters. 

 

This manual describes how to connect and remove the Copy Adapter and the "data copying," but none of other keypad functions. Note that the Copy 
Adapter does not allow you to control the inverter for running, stopping or other any operations except above mentioned. For other functions that are 
common to the built-in keypad, refer to the FRENIC-Mini Instruction Manual (INR-SI47-1205-E), Chapter 3. 

 

Before installing and using the Copy Adapter, read through this manual in conjunction with the FRENIC-Mini Instruction Manual and make yourself 
familiar with its proper use. Improper handling might result in incorrect operation, a short life, or even a failure of this product as well as the motor. 

 

Related Publications 

Listed below are other publications on the FRENIC-Mini to be consulted in conjunction with this manual as necessary. 
• FRENIC-Mini User’s Manual 

 

(MEH446) 

• FRENIC-Mini Instruction Manual 

 

(INR-SI47-1205-E) 

The materials are subject to change without notice. Be sure to obtain the latest editions for use. 

 

 Safety precautions 

Read this manual thoroughly before proceeding with installation, connections (wiring), operation, or maintenance and inspection. Ensure you have 
sound knowledge of the device and familiarize yourself with all safety information and precautions before proceeding to operate the inverter. 

 

Safety precautions are classified into the following two categories in this manual. 

 

Failure to heed the information indicated by this symbol may lead to dangerous conditions, possibly resulting in 
death or serious bodily injuries. 

 

Failure to heed the information indicated by this symbol may lead to dangerous conditions, possibly resulting in 
minor or light bodily injuries and/or substantial property damage. 

 

Failure to heed the information contained under the CAUTION title can also result in serious consequences. These safety precautions are of utmost 
importance and must be observed at all times. 

 

Operation

 

 

•  Turn on the inverter power after connecting the cable connector of the copy adapter into the inverter’s connector. 
•  Do not unplug the cable connector while the power is applied. 
•  Do not touch the copy adapter with wet hands. 
 

Doing so could cause electric shock. 

•  If you set the function codes wrongly or without completely understanding the instruction manuals and the FRENIC-Mini User's Manual, the 

motor may rotate with a torque or at a speed not permitted for the machine. 

 

An accident or injuries could occur.

 

•  Do not touch the inverter terminals while the power is applied to the inverter even if the inverter stops. 
 

Doing so could cause electric shock.

 

 

 

 

 

 

 

 

 

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание FRENIC Mini CPAD-C1A

Страница 1: ...edure for correct use Improper handling might result in incorrect operation a short life or even a failure of this product as well as the motor Deliver this manual to the end user of the product Keep...

Страница 2: ...or written permission from Fuji Electric Systems Co Ltd All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders The information cont...

Страница 3: ...nge without notice Be sure to obtain the latest editions for use Safety precautions Read this manual thoroughly before proceeding with installation connections wiring operation or maintenance and insp...

Страница 4: ...uit terminal block TB while power is applied Doing so could cause electric shock Be sure to keep the copy adapter s cable away from the live main circuit terminals An accident or electric shock could...

Страница 5: ...information which if not heeded can result in the inverter not operating to full efficiency as well as information concerning incorrect operations and settings which can result in accidents This icon...

Страница 6: ...e there any dents on the body 3 The model name CPAD C1A and SER No are printed on the back of the copy adapter as shown in Figure 1 1 If you suspect the product is not working properly or if you have...

Страница 7: ...check that the inverter is powered off To remove the control circuit terminal block TB cover insert your finger tip into the gap at the left of the PULL mark and pull the cover towards you If an RS48...

Страница 8: ...and make sure using a circuit tester or a similar instrument that the DC link bus voltage between the terminals P and N has dropped below a safe voltage 25 VDC Otherwise electric shock could occur A h...

Страница 9: ...able connector pinch its outside between your fingers and pull it towards you Pulling it off with the cable sheath may damage the cable Figure 2 3 Removing the Cable Connector 4 Restore the wirings in...

Страница 10: ...adapter Pressing this key cannot stop the motor in running RUN LED Lights when any run command is given to the inverter KEYPAD CONTROL LED Lights when the keypad is specified as a run command source...

Страница 11: ...ith the data protection function enabled the FRENIC Mini and the copy adapter show read and proT respectively on their 7 segment LED monitors 3 3 Data Copying Menu 7 of Data copying allows you to read...

Страница 12: ...ons some function code data cannot be copied to another inverter if the specifications of the destination inverter are different from those of the source inverter Which function code data can or canno...

Страница 13: ...he data copying function list Press the key again to return to the menu The function code data block number selected is preserved even after the copy adapter is removed from the inverter e data protec...

Страница 14: ...or is removed When the communications error is removed the copy adapter automatically enters the Running mode So retry the write operation or initialize If a write operation copy was in progress The o...

Страница 15: ...ieces of the connector adapters CPAD C1 CN come with the product for periodical replacement When you become to need more connector adapters CPAD C1 CN consult your Fuji Electric representative Table 4...

Страница 16: ...nd its adapter are illustrated down side up for convention of showing of their interlocking Figure 4 4 Inserting the New Connector Adapter 2 Insert the connector with the connector adapter into the lo...

Страница 17: ...lure phenomena and other circumstances 2 Product warranty The term of product warranty is one year after the purchase or 18 months from the month and year of production specified on the nameplate whic...

Страница 18: ...an inverter Cable connector Data storage space For 10 function code data blocks for 10 inverters Ambient temperature during storage 25 to 70 C 13 to 158 F Ambient humidity during storage 5 to 95 RH n...

Страница 19: ...the FRENIC Mini series of inverters Please feel free to send your comments regarding any errors or omissions you may have found or any suggestions you may have for generally improving the manual In n...

Страница 20: ...MEMO Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 21: ...Fuji Electric Systems Co Ltd Fuji Electric Corp of America Information subject to change without notice Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Отзывы: