Chapter 3  OPERATION USING THE COPY ADAPTER 

3.1 

 

Familiarizing Yourself with the Copy Adapter 

 

 

The copy adapter is composed of a 
4-digit, 7-segment LED monitor, an 
LED block consisting of 5 LEDs, and 
6 keys as shown in Figure 3.1. 

 
 
 
 
 

 

 

 

 

 

 

Figure 3.1  Overview of Copy Adapter 

STOP key

LED  
indicators

 

DOWN key 

UP key 

FUNCTION 
/DATA key 

Function code 
data block No. 
key 

7-segment LED monitor 

PROGRAM 
/RESET key 

Table 3.1  Names and Functions of Various Parts of Copy Adapter 

 

 

 

Item 

Monitor,  

LED Indicators 

and Keys 

Function Remarks 

LED 
Monitor 

7-segment  
LED monitor 

Displays information depending on the operation mode*. 

 key 

Switches the operation mode*. 

 key 

Switches the information displayed, fixes the function code data, 
or switches the alarm information displayed, depending on the 
operation mode. 
This key also enables or disables the data protection function. 

 key 
 key 

These keys are used to select the setting items displayed on the 
LED monitor and change the function code data. 

 key 

This key is used to select the function code data block number. 

Operation 
Keys 

 key 

Out of use for the copy adapter. 
(Pressing this key cannot stop the motor in running.) 

RUN LED 

Lights when any run command is given to the inverter. 

KEYPAD 
CONTROL LED 

Lights when the keypad is specified as a run command source. 

*Operation mode: 

• Running mode 
• Programming mode 
• Alarm mode 

kW, A, Hz, r/min, m/min: 
These three LEDs together as a group indicate the unit of the 
quantity being monitored. 

See Table 3.2. 
 

LED 
Indicators 

Unit/Mode LEDs 

PRG

 MODE

 

Two LEDs (right and left) light in Programming mode. 

 

 

  For the operation mode of the FRENIC-Mini and its operating procedures, refer to the FRENIC-Mini Instruction Manual (INR-SI47-1205-E), 

Chapter 3 "OPERATION USING THE KEYPAD." 

 
 
Table 3.2 lists the combinations of the three LEDs on the LED block, which indicate what is displayed on the 7-segment LED monitor. 

Table 3.2  Definition of LED Indication on the LED Block 

Indication on LED 

Unit 

Description 

 

 

Hz 

kW Hz 

Frequency 

 

 

Hz 

kW A 

Output 

current 

 

 

Hz 

kW kW 

Input 

power 

 

 

Hz 

kW 

r/min 

Load shaft speed 

 

 

Hz 

kW m/min 

Line 

speed 

 

 

Hz 

kW - 

Programming 

mode 

 

 

Hz 

kW 

Events other than above 

on

 off 

For details, refer to the FRENIC-Mini Instruction Manual (INR-SI47-1205-E), Chapter 3, Section 3.2.1 " Running mode [1] Monitor the running status." 

 

3-1 

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание FRENIC Mini CPAD-C1A

Страница 1: ...edure for correct use Improper handling might result in incorrect operation a short life or even a failure of this product as well as the motor Deliver this manual to the end user of the product Keep...

Страница 2: ...or written permission from Fuji Electric Systems Co Ltd All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders The information cont...

Страница 3: ...nge without notice Be sure to obtain the latest editions for use Safety precautions Read this manual thoroughly before proceeding with installation connections wiring operation or maintenance and insp...

Страница 4: ...uit terminal block TB while power is applied Doing so could cause electric shock Be sure to keep the copy adapter s cable away from the live main circuit terminals An accident or electric shock could...

Страница 5: ...information which if not heeded can result in the inverter not operating to full efficiency as well as information concerning incorrect operations and settings which can result in accidents This icon...

Страница 6: ...e there any dents on the body 3 The model name CPAD C1A and SER No are printed on the back of the copy adapter as shown in Figure 1 1 If you suspect the product is not working properly or if you have...

Страница 7: ...check that the inverter is powered off To remove the control circuit terminal block TB cover insert your finger tip into the gap at the left of the PULL mark and pull the cover towards you If an RS48...

Страница 8: ...and make sure using a circuit tester or a similar instrument that the DC link bus voltage between the terminals P and N has dropped below a safe voltage 25 VDC Otherwise electric shock could occur A h...

Страница 9: ...able connector pinch its outside between your fingers and pull it towards you Pulling it off with the cable sheath may damage the cable Figure 2 3 Removing the Cable Connector 4 Restore the wirings in...

Страница 10: ...adapter Pressing this key cannot stop the motor in running RUN LED Lights when any run command is given to the inverter KEYPAD CONTROL LED Lights when the keypad is specified as a run command source...

Страница 11: ...ith the data protection function enabled the FRENIC Mini and the copy adapter show read and proT respectively on their 7 segment LED monitors 3 3 Data Copying Menu 7 of Data copying allows you to read...

Страница 12: ...ons some function code data cannot be copied to another inverter if the specifications of the destination inverter are different from those of the source inverter Which function code data can or canno...

Страница 13: ...he data copying function list Press the key again to return to the menu The function code data block number selected is preserved even after the copy adapter is removed from the inverter e data protec...

Страница 14: ...or is removed When the communications error is removed the copy adapter automatically enters the Running mode So retry the write operation or initialize If a write operation copy was in progress The o...

Страница 15: ...ieces of the connector adapters CPAD C1 CN come with the product for periodical replacement When you become to need more connector adapters CPAD C1 CN consult your Fuji Electric representative Table 4...

Страница 16: ...nd its adapter are illustrated down side up for convention of showing of their interlocking Figure 4 4 Inserting the New Connector Adapter 2 Insert the connector with the connector adapter into the lo...

Страница 17: ...lure phenomena and other circumstances 2 Product warranty The term of product warranty is one year after the purchase or 18 months from the month and year of production specified on the nameplate whic...

Страница 18: ...an inverter Cable connector Data storage space For 10 function code data blocks for 10 inverters Ambient temperature during storage 25 to 70 C 13 to 158 F Ambient humidity during storage 5 to 95 RH n...

Страница 19: ...the FRENIC Mini series of inverters Please feel free to send your comments regarding any errors or omissions you may have found or any suggestions you may have for generally improving the manual In n...

Страница 20: ...MEMO Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Страница 21: ...Fuji Electric Systems Co Ltd Fuji Electric Corp of America Information subject to change without notice Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Отзывы: