10
Key display
/pi
FUNC PIPE
FUNC
OUTPUT
FUNC
DAMP
FUNC ZERO
FUNC DISP
FUNC
CUT OFF
FUNC
TOTAL
FUNC
FLOW SW
FUNC
STATUS
FUNC CAL
FUNC
SYSTEM
FUNC CHECK
Description of key (2/2)
Name
PIPE (Pipe)
OUTPUT
(Analog output)
DAMPING
(Damping)
ZERO (Zero)
DISPLAY
(Display panel)
CUT OFF
(Low flow cut)
TOTAL
(Integration)
FLOW SW
(Flow switch)
STATUS
(Status)
CAL.
(Calibration)
SYSTEM
(System)
CHECK (Check)
Description
By pressing this key, the circumstance of pipe, which has
been entered, is converted into the outside diameter.
(valid only when setting the outside diameter of pipe)
To enter the size and material of the sensor piping.
To set the condition of an analog output
(units, range, limit, burn-out)
To set the damping.
To use when zero adjustment is performed.
Keys used to change items or unit system on the measure-
ment display screen.
To set the low flow cut.
To set condition required for integration of flow rate.
(units, constant, preset value, integral switch, pulse width)
To set the measured high/low value switch
To set condition of status output (integration pulse, mea-
suring status)
To compensate indication values of zero point and 100%
point. (Current output is effected)
To switch the measuring unit system and language, or
confirm or calibrate analog output.
To display an error message and countermeasures when
an error appears.
(An error message is displayed on the upper-right of the
LCD.)
/pi