![Fuji Electric 6MBI800XV-075V-01 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/fuji-electric/6mbi800xv-075v-01/6mbi800xv-075v-01_mounting-instruction_2341761012.webp)
MT5F37311
© Fuji Electric Co., Ltd. All rights reserved.
6.1 Mounting direction of the IGBT module
Strictly observe the angle stated in the specification sheet for the mounting angle of the IGBT module.
If mounting at an angle out of the specification range, air bubble would be remained in the cooler when
cooling water is flowed. Air bubble might make cavitation phenomenon and it is cause of water leakage.
Also, since reliability under mounting conditions out of the specification has not been tested, we do
not know what kind of problems will occur.
6. Mounting of IGBT Module to Equipment
8
6.2 Method of fastening the IGBT module
Figure 8 shows the recommended procedure of tightening screws for mounting the IGBT module.
The fastening screws should be tightened with the specified torque.
See the specification for the specified torque and screws size to be used.
In addition, the use of self-tapping screws is not guaranteed.
Horizontal
and upward
Vertical
Vertical
Horizontal
but upside down
Fig. 7 IGBT module mounting direction