background image

 

 

- 8 -

Mode of operation 

Continuous operation 

Size (body) 

L145*W35*H40mm (Suitable for FT-F11, FT-F21 FT-F11-BT FT-F21-BT)
L120*W44*H60mm (Suitable for FT-F12, FT-F22 FT-F12-BT FT-F22-BT)
L132*W40.3*H65mm (Suitable for UO8080, UO8080E) 

Weight

including battery

 

78g(FT-F11,FT-F11-BT),80g(FT-F21,FT-F21-BT),  
48g(FT-F12,FT-F12-BT;FT-F22,FT-F22-BT)  

Contents 

-infrared thermometer   
-batteries 3V (Optional) 

-Storage case (Optional) 

-Instruction Manual 

Bluetooth Version 

Bluetooth 4.1 BLE 

Bluetooth Modulation Type 

GFSK 

 

Specially Voice Function for Model no.FT-F11, FT-F21, FT-F11-BT, 
FT-F21-BT, UO8080, UO8080E 

1.  When the IR thermometer is ready, you can hear

Please measure

voice or other 

languages voice. 

2.  When the measurement is finished, the IR thermometer shall report the measured 

temperature data. 

The Blue Tooth function model is FT-F11-BT, FT-F12-BT,FT-F21-BT 

FT-F22-BT) 

Operation Method: 

 Install the APK accordance with the communication protocol into the blue tooth 

signal receiving device such as mobile phone. 

 Activate the blue tooth signal receiving device such as mobile phone to match 

with the blue tooth of infrared thermometer 

 Start to measure according to the normal infrared thermometer operation 

method. 

  After measuring the result will be displayed on LCD and be sent to the blue tooth 

receiving device such as mobile phone. 

The additional function of blue tooth infrared thermometer is to transmit the testing result to 

the APK in the receiving device via blue tooth technology.   

Содержание FT-F11

Страница 1: ...1 Instruction for Use lnfrared Thermometer Contact Type FT F11 BT FT F21 BT FT F12 BT FT F22 BT FT F11 FT F21 FT F12 FT F22 UO8080 UO8080E...

Страница 2: ...Replacement 7 Operation Precautions 8 Precaution for Measuring Temperature 9 Product Specification 10 Common question concerning forehead temperature 2 Product Overview This infrared Thermometer measu...

Страница 3: ...Battery Last Memorized Temperature Display 5 Measuring 1 Ear Measuring Mode Figure 5 1 Suitable for FT F11 FT F11 BT FT F21 FT F21 BT FT F12 FT F12 BT FT F22 FT F22 BT UO8080 UO8080E Turn on the powe...

Страница 4: ...table for FT F21 FT F22 FT F21 BT FT F22 BT UO8080E Turn on the power button key of the IR Thermometer and then all displayed segments appear briefly as like on Figure 5 2A the displayed screen appear...

Страница 5: ...5 seconds until the displayed screen appears or then press the Scan button to switch to ear or forehead measuring mode 5 Memory recall 12 memories recall Press SCAN button key to display M on the disp...

Страница 6: ...lcohol IPA to clean up before or after use Avoid multiple using by different peoples for cross infection Note 1 Any solution dilution and method other than mentioned above might cause reliability prob...

Страница 7: ...attery type and battery life AAA 2pcs Suitable for FT F11 FT F21 FT F11 BT FT F21 BT UO8080 UO8080E 1 PC 2032 button battery Suitable for FT F12 FT F22 FT F12 BT FT F22 BT The typical service life of...

Страница 8: ...e measure voice or other languages voice 2 When the measurement is finished the IR thermometer shall report the measured temperature data The Blue Tooth function model is FT F11 BT FT F12 BT FT F21 BT...

Страница 9: ...he forehead area for temperature given off by the arterial blood supply under the skin without worrying about correct positioning The gentle scan is comfortable and not invasive Measurement method Nor...

Страница 10: ...nt Clinical accuracy characteristics and procedures are available from the manufacturer on request STATEMENTS AND DECLARATIONS 1 MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC an...

Страница 11: ...the receiver is connected Consult the dealer or an experienced radio TV technician for help 5 Guidance and manufacturer s delclaration Guidance and manufacture s declaration electromagnetic emission T...

Страница 12: ...5 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable Mains power quality should be that of a typical commercial or hosp...

Страница 13: ...EC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affect...

Страница 14: ...738 1 1 167 1 167 2 333 10 3 689 3 689 7 379 100 11 667 11 667 23 333 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estima...

Страница 15: ...ng instructions IP22 Symbol for the IP classification Symbol for RF transmitters Manufacturer FUDAKANG INDUSTRIAL CO LTD Address No 8 Yinghe Road Yuanjiangyuan Management Zone Changping Town Dongguan...

Отзывы: